Searcharxiv⌕ Search

arXiv subjects

Philippe Ciuciu

Publications and source records attributed to Philippe Ciuciu.

32 records · Page 2Linked to original sources

Anisotropic compressed sensing for non-Cartesian MRI acquisitions

In the present note we develop some theoretical results in the theory of anisotropic compressed sensing that allow to take structured sparsity and variable density structured sampling into account. We expect that the obtained results will be useful to derive explicit expressions for optimal sampling strategies in the non-Cartesian (radial, spiral, etc.) setting in MRI.

cs.IT↗

Structured Sparse Principal Components Analysis with the TV-Elastic Net penalty

Principal component analysis (PCA) is an exploratory tool widely used in data analysis to uncover dominant patterns of variability within a population. Despite its ability to represent a data set in a low-dimensional space, the interpretability of PCA remains limited. However, in neuroimaging, it is essential to uncover clinically interpretable phenotypic markers that would account for the main variability in the brain images of a population. Recently, some alternatives to the standard PCA approach, such as Sparse PCA, have been proposed, their aim being to limit the density of the components. Nonetheless, sparsity alone does not entirely solve the interpretability problem, since it may yield scattered and unstable components. We hypothesized that the incorporation of prior information regarding the structure of the data may lead to improved relevance and interpretability of brain patterns. We therefore present a simple extension of the popular PCA framework that adds structured sparsity penalties on the loading vectors in order to identify the few stable regions in the brain images accounting for most of the variability. Such structured sparsity can be obtained by combining l1 and total variation (TV) penalties, where the TV regularization encodes higher order information about the structure of the data. This paper presents the structured sparse PCA (denoted SPCA-TV) optimization framework and its resolution. We demonstrate the efficiency and versatility of SPCA-TV on three different data sets. The gains of SPCA-TV over unstructured approaches are significant,since SPCA-TV reveals the variability within a data set in the form of intelligible brain patterns that are easy to interpret, and are more stable across different samples.

stat.ML↗

A projection algorithm on measures sets

We consider the problem of projecting a probability measure $π$ on a set $\mathcal{M}\_N$ of Radon measures. The projection is defined as a solution of the following variational problem:\begin{equation*}\inf\_{μ\in \mathcal{M}\_N} \|h\star (μ- π)\|\_2^2,\end{equation*}where $h\in L^2(Ω)$ is a kernel, $Ω\subset \R^d$ and $\star$ denotes the convolution operator.To motivate and illustrate our study, we show that this problem arises naturally in various practical image rendering problems such as stippling (representing an image with $N$ dots) or continuous line drawing (representing an image with a continuous line).We provide a necessary and sufficient condition on the sequence $(\mathcal{M}\_N)\_{N\in \N}$ that ensures weak convergence of the projections $(μ^*\_N)\_{N\in \N}$ to $π$.We then provide a numerical algorithm to solve a discretized version of the problem and show several illustrations related to computer-assisted synthesis of artistic paintings/drawings.

math.NA↗

Hemodynamically informed parcellation of cerebral FMRI data

Standard detection of evoked brain activity in functional MRI (fMRI) relies on a fixed and known shape of the impulse response of the neurovascular coupling, namely the hemodynamic response function (HRF). To cope with this issue, the joint detection-estimation (JDE) framework has been proposed. This formalism enables to estimate a HRF per region but for doing so, it assumes a prior brain partition (or parcellation) regarding hemodynamic territories. This partition has to be accurate enough to recover accurate HRF shapes but has also to overcome the detection-estimation issue: the lack of hemodynamics information in the non-active positions. An hemodynamically-based parcellation method is proposed, consisting first of a feature extraction step, followed by a Gaussian Mixture-based parcellation, which considers the injection of the activation levels in the parcellation process, in order to overcome the detection-estimation issue and find the underlying hemodynamics.

stat.AP↗

Data-driven HRF estimation for encoding and decoding models

Despite the common usage of a canonical, data-independent, hemodynamic response function (HRF), it is known that the shape of the HRF varies across brain regions and subjects. This suggests that a data-driven estimation of this function could lead to more statistical power when modeling BOLD fMRI data. However, unconstrained estimation of the HRF can yield highly unstable results when the number of free parameters is large. We develop a method for the joint estimation of activation and HRF using a rank constraint causing the estimated HRF to be equal across events/conditions, yet permitting it to be different across voxels. Model estimation leads to an optimization problem that we propose to solve with an efficient quasi-Newton method exploiting fast gradient computations. This model, called GLM with Rank-1 constraint (R1-GLM), can be extended to the setting of GLM with separate designs which has been shown to improve decoding accuracy in brain activity decoding experiments. We compare 10 different HRF modeling methods in terms of encoding and decoding score in two different datasets. Our results show that the R1-GLM model significantly outperforms competing methods in both encoding and decoding settings, positioning it as an attractive method both from the points of view of accuracy and computational efficiency.

cs.CE↗

Variable density sampling with continuous trajectories. Application to MRI

Reducing acquisition time is a crucial challenge for many imaging techniques. Compressed Sensing (CS) theory offers an appealing framework to address this issue since it provides theoretical guarantees on the reconstruction of sparse signals by projection on a low dimensional linear subspace. In this paper, we focus on a setting where the imaging device allows to sense a fixed set of measurements. We first discuss the choice of an optimal sampling subspace (smallest subset) allowing perfect reconstruction of sparse signals. Its standard design relies on the random drawing of independent measurements. We discuss how to select the drawing distribution and show that a mixed strategy involving partial deterministic sampling and independent drawings can help breaking the so-called "coherence barrier". Unfortunately, independent random sampling is irrelevant for many acquisition devices owing to acquisition constraints. To overcome this limitation, the notion of Variable Density Samplers (VDS) is introduced and defined as a stochastic process with a prescribed limit empirical measure. It encompasses samplers based on independent measurements or continuous curves. The latter are crucial to extend CS results to actual applications. Our main contribution lies in two original continuous VDS. The first one relies on random walks over the acquisition space whereas the second one is heuristically driven and rests on the approximate solution of a Traveling Salesman Problem. Theoretical analysis and retrospective CS simulations in magnetic resonance imaging highlight that the TSP-based solution provides improved reconstructed images in terms of signal-to-noise ratio compared to standard sampling schemes (spiral, radial, 3D iid...).

stat.AP↗

Spatio-temporal wavelet regularization for parallel MRI reconstruction: application to functional MRI

Parallel MRI is a fast imaging technique that enables the acquisition of highly resolved images in space or/and in time. The performance of parallel imaging strongly depends on the reconstruction algorithm, which can proceed either in the original k-space (GRAPPA, SMASH) or in the image domain (SENSE-like methods). To improve the performance of the widely used SENSE algorithm, 2D- or slice-specific regularization in the wavelet domain has been deeply investigated. In this paper, we extend this approach using 3D-wavelet representations in order to handle all slices together and address reconstruction artifacts which propagate across adjacent slices. The gain induced by such extension (3D-Unconstrained Wavelet Regularized -SENSE: 3D-UWR-SENSE) is validated on anatomical image reconstruction where no temporal acquisition is considered. Another important extension accounts for temporal correlations that exist between successive scans in functional MRI (fMRI). In addition to the case of 2D+t acquisition schemes addressed by some other methods like kt-FOCUSS, our approach allows us to deal with 3D+t acquisition schemes which are widely used in neuroimaging. The resulting 3D-UWR-SENSE and 4D-UWR-SENSE reconstruction schemes are fully unsupervised in the sense that all regularization parameters are estimated in the maximum likelihood sense on a reference scan. The gain induced by such extensions is illustrated on both anatomical and functional image reconstruction, and also measured in terms of statistical sensitivity for the 4D-UWR-SENSE approach during a fast event-related fMRI protocol. Our 4D-UWR-SENSE algorithm outperforms the SENSE reconstruction at the subject and group levels (15 subjects) for different contrasts of interest (eg, motor or computation tasks) and using different parallel acceleration factors (R=2 and R=4) on 2x2x3mm3 EPI images.

stat.AP↗

From variable density sampling to continuous sampling using Markov chains

Since its discovery over the last decade, Compressed Sensing (CS) has been successfully applied to Magnetic Reso- nance Imaging (MRI). It has been shown to be a powerful way to reduce scanning time without sacrificing image quality. MR images are actually strongly compressible in a wavelet basis, the latter being largely incoherent with the k-space or spatial Fourier domain where acquisition is performed. Nevertheless, since its first application to MRI [1], the theoretical justification of actual k-space sampling strategies is questionable. Indeed, the vast majority of k-space sampling distributions have been heuris- tically designed (e.g., variable density) or driven by experimental feasibility considerations (e.g., random radial or spiral sampling to achieve smoothness k-space trajectory). In this paper, we try to reconcile very recent CS results with the MRI specificities (mag- netic field gradients) by enforcing the measurements, i.e. samples of k-space, to fit continuous trajectories. To this end, we propose random walk continuous sampling based on Markov chains and we compare the reconstruction quality of this scheme to the state- of-the art.

stat.AP↗

Variable Density Compressed Sensing In MRI. Theoretical vs Heuristic Sampling Strategies

The structure of Magnetic Resonance Images (MRI) and especially their compressibility in an appropriate representation basis enables the application of the compressive sensing theory, which guarantees exact image recovery from incomplete measurements. According to recent theoretical conditions on the reconstruction guarantees, the optimal strategy is to downsample the k-space using an independent drawing of the acquisition basis entries. Here, we first bring a novel answer to the synthesis problem, which amounts to deriving the op- timal distribution (according to a given criterion) from which the data should be sampled. Then, given that the sparsity hypothesis is not fulfilled in the k-space center in MRI, we extend this approach by densely sampling this center and drawing the remaining samples from the optimal distribution. We compare this theoretical approach to heuristic strategies, and show that the proposed two-stage process drastically improves reconstruction results on anatomical MRI.

math.ST↗

Travelling salesman-based variable density sampling

Compressed sensing theory indicates that selecting a few measurements independently at random is a near optimal strategy to sense sparse or compressible signals. This is infeasible in practice for many acquisition devices that acquire sam- ples along continuous trajectories. Examples include magnetic resonance imaging (MRI), radio-interferometry, mobile-robot sampling, ... In this paper, we propose to generate continuous sampling trajectories by drawing a small set of measurements independently and joining them using a travelling salesman problem solver. Our contribution lies in the theoretical derivation of the appropriate probability density of the initial drawings. Preliminary simulation results show that this strategy is as efficient as independent drawings while being implementable on real acquisition systems.

stat.AP↗

Fast joint detection-estimation of evoked brain activity in event-related fMRI using a variational approach

In standard clinical within-subject analyses of event-related fMRI data, two steps are usually performed separately: detection of brain activity and estimation of the hemodynamic response. Because these two steps are inherently linked, we adopt the so-called region-based Joint Detection-Estimation (JDE) framework that addresses this joint issue using a multivariate inference for detection and estimation. JDE is built by making use of a regional bilinear generative model of the BOLD response and constraining the parameter estimation by physiological priors using temporal and spatial information in a Markovian modeling. In contrast to previous works that use Markov Chain Monte Carlo (MCMC) techniques to approximate the resulting intractable posterior distribution, we recast the JDE into a missing data framework and derive a Variational Expectation-Maximization (VEM) algorithm for its inference. A variational approximation is used to approximate the Markovian model in the unsupervised spatially adaptive JDE inference, which allows fine automatic tuning of spatial regularisation parameters. It follows a new algorithm that exhibits interesting properties compared to the previously used MCMC-based approach. Experiments on artificial and real data show that VEM-JDE is robust to model mis-specification and provides computational gain while maintaining good performance in terms of activation detection and hemodynamic shape recovery.

stat.AP↗

4D Wavelet-Based Regularization for Parallel MRI Reconstruction: Impact on Subject and Group-Levels Statistical Sensitivity in fMRI

Parallel MRI is a fast imaging technique that enables the acquisition of highly resolved images in space. It relies on $k$-space undersampling and multiple receiver coils with complementary sensitivity profiles in order to reconstruct a full Field-Of-View (FOV) image. The performance of parallel imaging mainly depends on the reconstruction algorithm, which can proceed either in the original $k$-space (GRAPPA, SMASH) or in the image domain (SENSE-like methods). To improve the performance of the widely used SENSE algorithm, 2D- or slice-specific regularization in the wavelet domain has been efficiently investigated. In this paper, we extend this approach using 3D-wavelet representations in order to handle all slices together and address reconstruction artifacts which propagate across adjacent slices. The extension also accounts for temporal correlations that exist between successive scans in functional MRI (fMRI). The proposed 4D reconstruction scheme is fully \emph{unsupervised} in the sense that all regularization parameters are estimated in the maximum likelihood sense on a reference scan. The gain induced by such extensions is first illustrated on EPI image reconstruction but also measured in terms of statistical sensitivity during a fast event-related fMRI protocol. The proposed 4D-UWR-SENSE algorithm outperforms the SENSE reconstruction at the subject and group-levels (15 subjects) for different contrasts of interest and using different parallel acceleration factors on $2\times2\times3$mm$^3$ EPI images.

stat.ME↗

ICA-based sparse feature recovery from fMRI datasets

Spatial Independent Components Analysis (ICA) is increasingly used in the context of functional Magnetic Resonance Imaging (fMRI) to study cognition and brain pathologies. Salient features present in some of the extracted Independent Components (ICs) can be interpreted as brain networks, but the segmentation of the corresponding regions from ICs is still ill-controlled. Here we propose a new ICA-based procedure for extraction of sparse features from fMRI datasets. Specifically, we introduce a new thresholding procedure that controls the deviation from isotropy in the ICA mixing model. Unlike current heuristics, our procedure guarantees an exact, possibly conservative, level of specificity in feature detection. We evaluate the sensitivity and specificity of the method on synthetic and fMRI data and show that it outperforms state-of-the-art approaches.

stat.AP↗

An Iterative Method for Parallel MRI SENSE-based Reconstruction in the Wavelet Domain

To reduce scanning time and/or improve spatial/temporal resolution in some MRI applications, parallel MRI (pMRI) acquisition techniques with multiple coils acquisition have emerged since the early 1990s as powerful 3D imaging methods that allow faster acquisition of reduced Field of View (FOV) images. In these techniques, the full FOV image has to be reconstructed from the resulting acquired undersampled k-space data. To this end, several reconstruction techniques have been proposed such as the widely-used SENSE method. However, the reconstructed image generally presents artifacts when perturbations occur in both the measured data and the estimated coil sensitivity maps. In this paper, we aim at achieving good reconstructed image quality when using low magnetic field and high reduction factor. Under these severe experimental conditions, neither the SENSE method nor the Tikhonov regularization in the image domain give convincing results. To this aim, we present a novel method for SENSE-based reconstruction which proceeds with regularization in the complex wavelet domain. To further enhance the reconstructed image quality, local convex constraints are added in the regularization process. In vivo experiments carried out on Gradient-Echo (GRE) anatomical and Echo-Planar Imaging (EPI) functional MRI data at 1.5 Tesla indicate that the proposed algorithm provides reconstructed images with reduced artifacts for high reduction factor.

math.OC↗