SearcharxivSearch

arXiv subjects

Philippe Peille

Publications and source records attributed to Philippe Peille.

17 recordsLinked to original sources

Ground calibration plan for the Athena/X-IFU microcalorimeter spectrometer

The X-ray Integral Field Unit is the X-ray imaging spectrometer on-board one of ESA's next large missions, Athena. Athena is set to investigate the theme of the Hot and Energetic Universe, with a launch planned in the late-2030s. Based on a high sensitivity Transition Edge Sensor (TES) detector array operated at very low temperature (50 mK), X-IFU will provide spatially resolved high resolution spectroscopy of the X-ray sky in the 0.2-12 keV energy band, with an energy resolution goal of 4 eV up to 7 keV [3 eV design goal]. This paper presents the current calibration plan of the X-IFU. It provides the requirements applicable to the X-IFU calibration, describes the overall calibration strategy, and details the procedure and sources needed for the ground calibration of each parameter or characteristics of the X-IFU.

astro-ph.IM

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4' field of view (compared to 5' before). In this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

astro-ph.IM

The first cut is the cheapest: optimizing Athena/X-IFU-like TES detectors resolution by filter truncation

The X-ray Integral Field Unit (X-IFU) instrument on the future ESA mission Athena X-ray Observatory is a cryogenic micro-calorimeter array of Transition Edge Sensor (TES) detectors designed to provide spatially-resolved high-resolution spectroscopy. The onboard reconstruction software provides energy, spatial location and arrival time of incoming X-ray photons hitting the detector. A new processing algorithm based on a truncation of the classical optimal filter and called 0-padding, has been recently proposed aiming to reduce the computational cost without compromising energy resolution. Initial tests with simple synthetic data displayed promising results. This study explores the slightly better performance of the 0-padding filter and assess its final application to real data. The goal is to examine the larger sensitivity to instrumental conditions that was previously observed during the analysis of the simulations. This 0-padding technique is thoroughly tested using more realistic simulations and real data acquired from NASA and NIST laboratories employing X-IFU-like TES detectors. Different fitting methods are applied to the data, and a comparative analysis is performed to assess the energy resolution values obtained from these fittings. The 0-padding filter achieves energy resolutions as good as those obtained with standard filters, even with those of larger lengths, across different line complexes and instrumental conditions. This method proves to be useful for energy reconstruction of X-ray photons detected by the TES detectors provided proper corrections for baseline drift and jitter effects are applied. The finding is highly promising especially for onboard processing, offering efficiency in computational resources and facilitating the analysis of sources with higher count rates at high resolution.

astro-ph.IM

Toward mapping turbulence in the intracluster medium III. Constraints on the turbulent power spectrum with Athena/X-IFU

Context. Future X-ray observatories with high spectral resolution and imaging capabilities will enable measurements and mappings of emission line shifts in the intracluster medium (ICM). Such direct measurements can serve as unique probes of turbulent motions in the ICM. Determining the level and scales of turbulence will improve our understanding of the galaxy cluster dynamical evolution and assembly, together with a more precise evaluation of the non thermal support pressure budget. This will allow for more accurate constraints to be placed on the masses of galaxy clusters, among other potential benfits. Aims. In this view, we implemented the methods presented in the previous instalments of our work to characterize the turbulence in the ICM in a feasibility study with the X-IFU on board the future European X-ray observatory, Athena. Methods. From idealized mock observations of a toy model cluster, we reconstructed the second-order structure function built with the observed velocity field to constrain the turbulence. We carefully accounted for the various sources of errors to derive the most realistic and comprehensive error budget within the limits of our approach. With prior assumptions on the dissipation scale and power spectrum slope, we constrained the parameters of the turbulent power spectrum model through the use of MCMC sampling. Results. With favourable assumptions, we were able to retrieve the injection scale, velocity dispersion, and power spectrum slope, with 1sigma uncertainties better than ~15% of the input values. We demonstrated the efficiency of our carefully set framework to constrain the turbulence in the ICM from high-resolution X-ray spectroscopic observations, paving the way for more in-depth investigation of the optimal required observing strategy within a more restrictive observational setup with the future X-IFU instrument.

astro-ph.CO

The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. (abridged).

astro-ph.IM

A 50 mK test bench for demonstration of the readout chain of Athena/X-IFU

The X-IFU (X-ray Integral Field Unit) onboard the large ESA mission Athena (Advanced Telescope for High ENergy Astrophysics), planned to be launched in the mid 2030s, will be a cryogenic X-ray imaging spectrometer operating at 55 mK. It will provide unprecedented spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) in the 0.2-12 keV energy range thanks to its array of TES (Transition Edge Sensors) microcalorimeters of more than 2k pixel. The detection chain of the instrument is developed by an international collaboration: the detector array by NASA/GSFC, the cold electronics by NIST, the cold amplifier by VTT, the WFEE (Warm Front-End Electronics) by APC, the DRE (Digital Readout Electronics) by IRAP and a focal plane assembly by SRON. To assess the operation of the complete readout chain of the X-IFU, a 50 mK test bench based on a kilo-pixel array of microcalorimeters from NASA/GSFC has been developed at IRAP in collaboration with CNES. Validation of the test bench has been performed with an intermediate detection chain entirely from NIST and Goddard. Next planned activities include the integration of DRE and WFEE prototypes in order to perform an end-to-end demonstration of a complete X-IFU detection chain.

astro-ph.IM

Pulse processing in TES detectors: comparison of different short filter methods based on optimal filtering. Case study for Athena X-IFU

In the framework of the ESA Athena mission, the X-ray Integral Field Unit (X-IFU) instrument to be on board the X-ray Athena Observatory is a cryogenic micro-calorimeter array of Transition Edge Sensor (TES) detectors aimed at providing spatially resolved high-resolution spectroscopy. As a part of the on-board Event Processor (EP), the reconstruction software will provide the energy, spatial location and arrival time of the incoming X-ray photons hitting the detector and inducing current pulses on it. Being the standard optimal filtering technique the chosen baseline reconstruction algorithm, different modifications have been analyzed to process pulses shorter than those considered of high resolution (those where the full length is not available due to a close pulse after them) in order to select the best option based on energy resolution and computing performance results. It can be concluded that the best approach to optimize the energy resolution for short filters is the 0-padding filtering technique, benefiting also from a reduction in the computational resources. However, its high sensitivity to offset fluctuations currently prevents its use as the baseline treatment for the X-IFU application for lack of consolidated information on the actual stability it will get in flight.

astro-ph.IM

Thermal simulations of temperature excursions on the Athena X-IFU detector wafer from impacts by cosmic rays

We present the design and implementation of a thermal model, developed in COMSOL, aiming to probe the wafer-scale thermal response arising from realistic rates and energies of cosmic rays at L2 impacting the detector wafer of Athena X-IFU. The wafer thermal model is a four-layer 2D model, where 2 layers represent the constituent materials (Si bulk and Si$_{3}$N$_{4}$ membrane), and 2 layers represent the Au metallization layer's phonon and electron temperatures. We base the simulation geometry on the current specifications for the X-IFU detector wafer, and simulate cosmic ray impacts using a simple power injection into the Si bulk. We measure the temperature at the point of the instrument's most central TES detector. By probing the response of the system and pulse characteristics as a function of the thermal input energy and location, we reconstruct cosmic ray pulses in Python. By utilizing this code, along with the results of the GEANT4 simulations produced for X-IFU, we produce realistic time-ordered data (TOD) of the temperature seen by the central TES, which we use to simulate the degradation of the energy resolution of the instrument in space-like conditions on this wafer. We find a degradation to the energy resolution of 7 keV X-rays of $\approx$0.04 eV. By modifying wafer parameters and comparing the simulated TOD, this study is a valuable tool for probing design changes on the thermal background seen by the detectors.

astro-ph.IM

Modeling the upper kHz QPOs of 4U 1728-34 with X-ray reverberation

While kilohertz quasi-periodic oscillations (kHz QPOs) have been well studied for decades since their initial discovery, the cause of these signals remains unknown, as no model has been able to accurately predict all of their spectral and timing properties. Separately, X-ray reverberation lags have been detected in AGN and stellar-mass black hole binaries, and reverberation may be expected to occur in neutron star systems as well, producing lags of the same amplitude as the lags measured of the kHz QPOs. Furthermore, the detection of a relativistically reflected Fe K line in the time-averaged spectra of many neutron star systems provides an additional motivation for testing reverberation. While it has been shown that the lag-energy properties of the lower kHz QPOs are unlikely to be produced by X-ray reverberation, the upper kHz QPOs have not yet been explored. We therefore model the upper kHz QPO lag-energy spectra using relativistic ray-tracing functions and apply them to archival RXTE data on 4U 1728-34 where upper kHz QPOs have been detected. By modeling the time-averaged spectra in which upper kHz QPOs had been significantly detected, we determine the reflected flux fraction across all energies and produce a model for the lag-energy spectra from X-ray reverberation. We explore the dependence of the modeled lag properties on several different types of reflection models, but are unable to successfully reproduce the measured lags of 4U 1728-34. We conclude that reverberation alone does not explain the measured time lags detected in upper kHz QPOs.

astro-ph.HE

SIXTE -- The Generic X-ray Instrument Simulation Toolkit

We give an overview of the SImulation of X-ray TElescopes (SIXTE) software package, a generic, mission-independent Monte Carlo simulation toolkit for X-ray astronomical instrumentation. The package is based on a modular approach for the source definition, the description of the optics, and the detector type such that new missions can be easily implemented. The targets to be simulated are stored in a flexible input format called SIMPUT. Based on this source definition, a sample of photons is produced and then propagated through the optics. In order to model the detection process, the software toolkit contains modules for various detector types, ranging from proportional counter and Si-based detectors, to more complex descriptions like transition edge sensor (TES) devices. The implementation of characteristic detector effects and a detailed modeling of the read-out process allow for representative simulations and therefore enable the analysis of characteristic features, such as for example pile-up, and their impact on observations. We present an overview of the implementation of SIXTE from the input source, the imaging, and the detection process, highlighting the modular approach taken by the SIXTE software package. In order to demonstrate the capabilities of the simulation software, we present a selection of representative applications, including the all-sky survey of eROSITA and a study of pile-up effects comparing the currently operating XMM-Newton with the planned Athena-WFI instrument. A simulation of a galaxy cluster with the Athena- X-IFU shows the capability of SIXTE to predict the expected performance of an observation for a complex source with a spatially varying spectrum and our current knowledge of the future instrument.

astro-ph.HE

The Athena X-ray Integral Field Unit

The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5' equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a spectral resolution of 2.5 eV up to 7 keV on ~5 arcsecond pixels. The X-IFU is based on a large format array of super-conducting molybdenum-gold Transition Edge Sensors cooled at about 90 mK, each coupled with an absorber made of gold and bismuth with a pitch of 249 microns. A cryogenic anti-coincidence detector located underneath the prime TES array enables the non X-ray background to be reduced. A bath temperature of about 50 mK is obtained by a series of mechanical coolers combining 15K Pulse Tubes, 4K and 2K Joule-Thomson coolers which pre-cool a sub Kelvin cooler made of a 3He sorption cooler coupled with an Adiabatic Demagnetization Refrigerator. Frequency domain multiplexing enables to read out 40 pixels in one single channel. A photon interacting with an absorber leads to a current pulse, amplified by the readout electronics and whose shape is reconstructed on board to recover its energy with high accuracy. The defocusing capability offered by the Athena movable mirror assembly enables the X-IFU to observe the brightest X-ray sources of the sky (up to Crab-like intensities) by spreading the telescope point spread function over hundreds of pixels. Thus the X-IFU delivers low pile-up, high throughput (>50%), and typically 10 eV spectral resolution at 1 Crab intensities, i.e. a factor of 10 or more better than Silicon based X-ray detectors. In this paper, the current X-IFU baseline is presented, together with an assessment of its anticipated performance in terms of spectral resolution, background, and count rate capability. The X-IFU baseline configuration will be subject to a preliminary requirement review that is scheduled at the end of 2018.

astro-ph.IM

Reproducibility and monitoring of the instrumental particle background for the X-Ray Integral Field Unit

The X-ray Integral Field Unit (X-IFU) is the cryogenic imaging spectrometer on board the future X-ray observatory \textsl{Athena}. With a hexagonal array of 3840 AC-biased Transition Edge Sensors (TES), it will provide narrow-field observations (5$^{\prime}$ equivalent diameter) with unprecedented high spectral resolution (2.5 eV up to 7 keV) over the 0.2 - 12 keV bandpass. Throughout its observations, the X-IFU will face various sources of X-ray background. Specifically, the so-called Non-X-ray Background (NXB) caused by the interaction of high-energy cosmic rays with the instrument, may lead to a degradation of its sensitivity in the observation of faint extended sources (e.g. galaxy clusters outskirts). To limit this effect, a cryogenic anti-coincidence detector (CryoAC) will be placed below the detector plane to lower the NXB level down to the required level of $5 \times 10^{-3}$ cts/s/cm$^{2}$/keV over 2 - 10 keV. In this contribution, we investigate ways to accurately monitor the NXB and ensure the highest reproducibility in-flight. Using the limiting science case of the background-dominated observation of galaxy clusters outskirts, we demonstrate that a reproducibility of 2\% on the absolute knowledge of the background is required to perform driving science objectives, such as measuring abundances and turbulence in the outskirts. Monitoring of the NXB in-flight through closed observations, the detector's CryoAC or the companion instrument (Wide Field Imager) will be used to meet this requirement.

astro-ph.IM

Testing the X-IFU calibration requirements: an example for quantum efficiency and energy resolution

With its array of 3840 Transition Edge Sensors (TESs) operated at 90 mK, the X-Ray Integral Field Unit (X-IFU) on board the ESA L2 mission Athena will provide spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) over the 0.2 to 12 keV bandpass. The in-flight performance of the X-IFU will be strongly affected by the calibration of the instrument. Uncertainties in the knowledge of the overall system, from the filter transmission to the energy scale, may introduce systematic errors in the data, which could potentially compromise science objectives - notably those involving line characterisation e.g. turbulence velocity measurements - if not properly accounted for. Defining and validating calibration requirements is therefore of paramount importance. In this paper, we put forward a simulation tool based on the most up-to-date configurations of the various subsystems (e.g. filters, detector absorbers) which allows us to estimate systematic errors related to uncertainties in the instrumental response. Notably, the effect of uncertainties in the energy resolution and of the instrumental quantum efficiency on X-IFU observations is assessed, by taking as a test case the measurements of the iron K complex in the hot gas surrounding clusters of galaxies. In-flight and ground calibration of the energy resolution and the quantum efficiency is also addressed. We demonstrate that provided an accurate calibration of the instrument, such effects should be low in both cases with respect to statistics during observations.

astro-ph.IM

Energy scale calibration and drift correction of the X-IFU

The Athena X-Ray Integral Field Unit (X-IFU) will provide spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) over the 0.2 to 12 keV energy band. It will comprise an array of 3840 superconducting Transition Edge Sensors (TESs) operated at 90 mK, with an absolute energy scale accuracy of 0.4 eV. Slight changes in the TES operating environment can cause significant variations in its energy response function, which may result in degradation of the detector's energy resolution, and eventually in systematic errors in the absolute energy scale if not properly corrected. These changes will be monitored via an onboard Modulated X-ray Source (MXS) and the energy scale will be corrected accordingly using a multi-parameter interpolation of gain curves obtained during ground calibration. Assuming realistic MXS configurations and using the instrument end-to-end simulator SIXTE, we investigate here both statistical and systematic effects on the X-IFU energy scale, occurring either during ground measurements or in-flight. The corresponding impacts on the energy resolution and means of accounting for these errors are also addressed. We notably demonstrate that a multi-parameter gain correction, using both the pulse-height estimate and the baseline of a pulse, can accurately recover systematic effects on the gain due to realistic changes in TES operating conditions within 0.4 eV. Optimisations of this technique with respect to the MXS line configuration and correction time, as well as to the energy scale parametrization are also show promising results to improve the accuracy of the correction.

astro-ph.IM

A Systematic Spectral-Timing Analysis of Kilohertz Quasi-Periodic Oscillations in the Rossi X-ray Timing Explorer Archive

Kilohertz quasi-periodic oscillations or kHz QPOs occur on the orbital timescale of the inner accretion flow and may carry signatures of the physics of strong gravity (c$^{2}$ ~ GM/R) and possibly clues to constraining the neutron star equation of state (EOS). Both the timing behavior of kHz QPOs and the time-averaged spectra of these systems have been studied extensively, yet no model completely describes all the properties of kHz QPOs. Here, we present a systematic study of spectral-timing products of kHz QPOs from low-mass X-ray binary systems using archival Rossi X-ray Timing Explorer/Proportional Counter Array data. For the lower kHz QPOs in fourteen objects and the upper kHz QPOs in six, we were able to obtain correlated time-lags as a function of QPO frequency and energy, as well as energy-dependent covariance spectra and intrinsic coherence. For the lower kHz QPOs, we find a monotonic decrease in lags with increasing energy, rising covariance to ~12 keV, and near unity coherence at all energies. For the upper kHz QPOs, we find near zero lags, rising covariance to ~12 keV, and less well-constrained coherence at all energies. These results suggest that while kHz QPOs are likely produced by similar mechanisms across the population of LMXBs, the lower kHz QPOs are likely produced by a different mechanism than upper kHz QPOs

astro-ph.HE

The Athena X-ray Integral Field Unit (X-IFU)

The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for High-ENergy Astrophysics (Athena) will provide spatially resolved high-resolution X-ray spectroscopy from 0.2 to 12 keV, with 5 arc second pixels over a field of view of 5 arc minute equivalent diameter and a spectral resolution of 2.5 eV up to 7 keV. In this paper, we first review the core scientific objectives of Athena, driving the main performance parameters of the X-IFU, namely the spectral resolution, the field of view, the effective area, the count rate capabilities, the instrumental background. We also illustrate the breakthrough potential of the X-IFU for some observatory science goals. Then we briefly describe the X-IFU design as defined at the time of the mission consolidation review concluded in May 2016, and report on its predicted performance. Finally, we discuss some options to improve the instrument performance while not increasing its complexity and resource demands (e.g. count rate capability, spectral resolution). The X-IFU will be provided by an international consortium led by France, The Netherlands and Italy, with further ESA member state contributions from Belgium, Finland, Germany, Poland, Spain, Switzerland and two international partners from the United States and Japan.

astro-ph.IM

The spectral-timing properties of upper and lower kHz QPOs

Soft lags from the emission of the lower kilohertz quasi-periodic oscillations (kHz QPOs) of neutron star low mass X-ray binaries have been reported from 4U1608-522 and 4U1636-536. Those lags hold prospects for constraining the origin of the QPO emission. In this paper, we investigate the spectral-timing properties of both the lower and upper kHz QPOs from the neutron star binary 4U1728-34, using the entire Rossi X-ray Timing Explorer archive on this source. We show that the lag-energy spectra of the two QPOs are systematically different: while the lower kHz QPO shows soft lags, the upper kHz QPO shows either a flat lag-energy spectrum or hard variations lagging softer variations. This suggests two different QPO-generation mechanisms. We also performed the first spectral deconvolution of the covariance spectra of both kHz QPOs. The QPO spectra are consistent with Comptonized blackbody emission, similar to the one found in the time-averaged spectrum, but with a higher seed-photon temperature, suggesting that a more compact inner region of the Comptonization layer (boundary/spreading layer, corona) is responsible for the QPO emission. Considering our results together with other recent findings, this leads us to the hypothesis that the lower kHz QPO signal is generated by coherent oscillations of the compact boundary layer region itself. The upper kHz QPO signal may then be linked to less-coherent accretion-rate variations produced in the inner accretion disk, being detected when they reach the boundary layer.

astro-ph.HE