Respiratory and cardiac monitoring at night using a wrist wearable optical system

Sleep monitoring provides valuable insights into the general health of an individual and helps in the diagnostic of sleep-derived illnesses. Polysomnography, is considered the gold standard for such task. However, it is very unwieldy and therefore not suitable for long-term analysis. Here, we present a non-intrusive wearable system that, by using photoplethysmography, it can estimate beat-to-beat intervals, pulse rate, and breathing rate reliably during the night. The performance of the proposed approach was evaluated empirically in the Department of Psychology at the University of Fribourg. Each participant was wearing two smart-bracelets from Ava as well as a complete polysomnographic setup as reference. The resulting mean absolute errors are 17.4 ms (MAPE 1.8%) for the beat-to-beat intervals, 0.13 beats-per-minute (MAPE 0.20%) for the pulse rate, and 0.9 breaths-per-minute (MAPE 6.7%) for the breath rate.

eess.SP

Detection of Beat-to-Beat Intervals from Wrist Photoplethysmography in Patients with Sinus Rhythm and Atrial Fibrillation after Surgery

Wrist photoplethysmography (PPG) allows unobtrusive monitoring of the heart rate (HR). PPG is affected by the capillary blood perfusion and the pumping function of the heart, which generally deteriorate with age and due to presence of cardiac arrhythmia. The performance of wrist PPG in monitoring beat-to-beat HR in older patients with arrhythmia has not been reported earlier. We monitored PPG from wrist in 18 patients recovering from surgery in the post anesthesia care unit, and evaluated the inter-beat interval (IBI) detection accuracy against ECG based R-to-R intervals (RRI). Nine subjects had sinus rhythm (SR, 68.0y$\pm$10.2y, 6 males) and nine subjects had atrial fibrillation (AF, 71.3y$\pm$7.8y, 4 males) during the recording. For the SR group, 99.44% of the beats were correctly identified, 2.39% extra beats were detected, and the mean absolute error (MAE) was 7.34 ms. For the AF group, 97.49% of the heartbeats were correctly identified, 2.26% extra beats were detected, and the MAE was 14.31 ms. IBI from the PPG were hence in close agreement with the ECG reference in both groups. The results suggest that wrist PPG provides a comfortable alternative to ECG and can be used for long-term monitoring and screening of AF episodes.

eess.SP

Learning a Physical Activity Classifier for a Low-power Embedded Wrist-located Device

This article presents and evaluates a novel algorithm for learning a physical activity classifier for a low-power embedded wrist-located device. The overall system is designed for real-time execution and it is implemented in the commercial low-power System-on-Chips nRF51 and nRF52. Results were obtained using a database composed of 140 users containing more than 340 hours of labeled raw acceleration data. The final precision achieved for the most important classes, (Rest, Walk, and Run), was of 96%, 94%, and 99% and it generalizes to compound activities such as XC skiing or Housework. We conclude with a benchmarking of the system in terms of memory footprint and power consumption.

eess.SP