Spatial Mapping and Capacitor Trimming Developments to Improve Usable Pixel Yield in PRIMA FIRESS Kilo-Pixel Arrays

The Probe far-Infrared Mission for Astrophysics (PRIMA) will use 8 kilo-pixel kinetic inductance detector (KID) arrays in its spectrometer module. We present an improved resonant frequency to spatial position mapping system designed to preserve each array's mapping after transferring it from the mapping apparatus to the flight housing. Such a mapping is necessary for astronomical observations, and additionally allows us to laser trim the capacitive elements of KIDs to optimize resonance separation in frequency space. This increases the operating yield by eliminating collided resonances, reduces crosstalk, and reduces the sensitivity to frequency drift over time.

astro-ph.IM

Radiation Total Dose for PRIMA: Cold Exposure with Alpha Particles

The Probe far-Infrared Mission for Astrophysics (PRIMA) is a far-infrared (24-261 micron wavelengths) probe-class space observatory currently under Phase A study, which promises orders-of-magnitude improvement in mapping speed over its predecessors. PRIMA will field exquisitely sensitive kilopixel arrays of kinetic inductance detectors (KIDs) for the Far-Infrared Enhanced Survey Spectrometer (FIRESS) instrument. PRIMA will orbit in space at the Sun-Earth L2 point, where Planck found the energetic particle flux to be about 300/min/cm2. Thus, the possible effect of a high fluence of energetic particles on the detector sensitivity must be characterized. Previous work has suggested that bombardment of KIDs by ions can reduce the quasiparticle lifetime (Barends et. al. 2009), but the conditions of the experiment were not representative of a detector which is continuously held at sub-Kelvin temperatures in the energetic particle environment of L2 orbit. To better replicate the damage which would be produced by energetic particles in this environment, we developed a fully cryogenic irradiation experiment in which a stepper motor controls a screen which can block or reveal an alpha particle emitter. This setup can be used to irradiate aluminum KID arrays fabricated for FIRESS to well-controlled dose levels. In this work, we calculate the damage dose expected for a 5-year mission in L2 orbit, and we irradiate an array to approximately 62 percent of this level. Before and after irradiation, we measure the quasiparticle lifetimes, resonant frequencies, and quality factors of the detectors.

astro-ph.IM

Development of an ultra-sensitive 210-micron array of KIDs for far-IR astronomy

The Probe far-Infrared Mission for Astrophysics (PRIMA) is a proposed space observatory which will use arrays of thousands of kinetic inductance detectors (KIDs) to perform low- and moderate-resolution spectroscopy throughout the far-infrared. The detectors must have noise equivalent powers (NEPs) at or below 0.1 aW/sqrt(Hz) to be subdominant to noise from sky backgrounds and thermal noise from PRIMA's cryogenically cooled primary mirror. Using a Radio Frequency System on a Chip for multitone readout, we measure the NEPs of detectors on a flight-like array designed to observe at a wavelength of 210 microns. We find that 92% of the KIDs measured have an NEP below 0.1 aW/sqrt(Hz) at a noise frequency of 10 Hz.

astro-ph.IM

A 25-micron single photon sensitive kinetic inductance detector

We report measurements characterizing the performance of a kinetic inductance detector array designed for a wavelength of 25 microns and very low optical background level suitable for applications such as a far-infrared instrument on a cryogenically cooled space telescope. In a pulse counting mode of operation at low optical flux, the detectors can resolve individual 25-micron photons. In an integrating mode, the detectors remain photon noise limited over more than six orders of magnitude in absorbed power from 70 zW to 200 fW, with a limiting NEP of 4.6 x 10^-20 W/rtHz at 1 Hz. In addition, the detectors are highly stable with flat power spectra under optical load down to 1 mHz. Operational parameters of the detector are determined including the efficiency of conversion of the incident optical power into quasiparticles in the aluminum absorbing element and the quasiparticle self-recombination constant.

astro-ph.IM

High-sensitivity Kinetic Inductance Detector Arrays for the Probe Far-Infrared Mission for Astrophysics

Far-infrared (far-IR) astrophysics missions featuring actively cooled telescopes will offer orders of magnitude observing speed improvement at wavelengths where galaxies and forming planetary systems emit most of their light. The PRobe far-Infrared Mission for Astrophysics (PRIMA), which is currently under study, emphasizes low and moderate resolution spectroscopy throughout the far-IR. Full utilization of PRIMA's cold telescope requires far-IR detector arrays with per-pixel noise equivalent powers (NEPs) at or below 1 x 10-19 W/rtHz. We are developing low-volume Aluminum kinetic inductance detector (KID) arrays to reach these sensitivities. We will present on the development of our long-wavelength (210 um) array approach, with a focus on multitone measurements of our 1,008-pixel arrays. We measure an NEP below 1 x 10-19 W/rtHz for 73 percent of our pixels.

astro-ph.IM

Parallel Plate Capacitor Aluminum KIDs for Future Far-Infrared Space-Based Observatories

Future space-based far-infrared astrophysical observatories will require exquis-itely sensitive detectors consistent with the low optical backgrounds. The PRobe far-Infrared Mission for Astrophysics (PRIMA) will deploy arrays of thousands of superconducting kinetic inductance detectors (KIDs) sensitive to radiation between 25 and 265 $\mu$m. Here, we present laboratory characterization of prototype, 25 -- 80 $\mu$m wavelength, low-volume, aluminum KIDs designed for the low-background environment expected with PRIMA. A compact parallel plate capacitor is used to minimize the detector footprint and suppress TLS noise. A novel resonant absorber is designed to enhance response in the band of interest. We present noise and optical efficiency measurements of these detectors taken with a low-background cryostat and a cryogenic blackbody. A microlens-hybridized KID array is found to be photon noise limited down to about 50 aW with a limiting detector NEP of about $6.5 \times 10^{-19}~\textrm{W/Hz}^{1/2}$. A fit to an NEP model shows that our optical system is well characterized and understood down to 50 aW. We discuss future plans for low-volume aluminum KID array development as well as the testbeds used for these measurements.

astro-ph.IM

High-sensitivity transition-edge-sensed bolometers: improved speed and characterization with AC and DC bias

We report on efforts to improve the speed of low-G far-infrared transition-edged-sensed bolometers. We use a fabrication process that does not require any dry etch steps to reduce heat capacity on the suspended device and measure a reduction in the detector time constant. However, we also measure an increase in the temperature-normalized thermal conductance (G), and a corresponding increase in the noise-equivalent power (NEP). We employ a new near-IR photon-noise technique using a near-IR laser to calibrate the frequency-domain multiplexed AC system and compare the results to a well-understood DC circuit. We measure an NEP white noise level of 0.8 aW/rtHz with a 1/f knee below 0.1 Hz and a time constant of 3.2 ms.

physics.app-ph