SearcharxivSearch

arXiv subjects

Pierre-Alain Loizeau

Publications and source records attributed to Pierre-Alain Loizeau.

2 recordsLinked to original sources

Performance of the Endcap Time-of-Flight detector in the STAR beam-energy scan

The STAR experiment at RHIC at Brookhaven National Laboratory completed the installation of an endcap time-of-flight subsystem (eTOF) in February 2019. The eTOF subsystem provided essential mid-rapidity particle identification (PID) for the fixed-target (FXT) portion of phase II of the beam energy scan (BES II). The FXT program allowed BES II to include center-of-mass energies from $\sqrt{s_{_{NN}}} = 3.0$ GeV to $\sqrt{s_{_{NN}}} = 7.7$ GeV, not accessible by colliding beams. The eTOF detectors and readout electronics were designed for the CBM experiment at FAIR and adapted for use at STAR. In this paper, we describe the details of the system in terms of geometrical layout, acceptance, calibration, hit reconstruction, and particle identification. The system achieved a time resolution of about 70 ps and a PID efficiency of about 70\%, meeting the design goals of the project.

physics.ins-det

Development and test of a real-size MRPC for CBM-TOF

In the CBM (Compressed Baryonic Matter) experiment constructed at the Facility for Anti-proton and Ion Research (Fair) at GSI, Darmstadt, Germany, MRPC(Multi-gap Resistive Plate Chamber) is adopted to construct the large TOF (Time-of-Flight) system to achieve an unprecedented precision of hadron identification, benefiting from its good time resolution, relatively high efficiency and low building price. We have developed a kind of double-ended readout strip MRPC. It uses low resistive glass to keep good performance of time resolution under high-rate condition. The differential double stack structure of 2x4 gas gaps help to reduce the required high voltage to half. There are 24 strips on one counter, and each is 270mm long, 7mm wide and the interval is 3mm. Ground is placed onto the MRPC electrode and feed through is carefully designed to match the 100 Ohm impedance of PADI electronics. The prototype of this strip MRPC has been tested with cosmic ray, a 98% efficiency and 60ps time resolution is gotten. In order to further examine the performance of the detector working under higher particle flux rate, the prototype has been tested in the 2014 October GSI beam time and 2015 February CERN beam time. In both beam times a relatively high rate of 1 kHz/cm2 was obtained. The calibration is done with CBM ROOT. A couple of corrections has been considered in the calibration and analysis process (including time-walk correction, gain correction, strip alignment correction and velocity correction) to access actual counter performances such as efficiency and time resolution. An efficiency of 97% and time resolution of 48ps are obtained. All these results show that the real-size prototype is fully capable of the requirement of the CBM-TOF, and new designs such as self-sealing are modified into the strip counter prototype to obtain even better performance.

physics.ins-det