Searcharxiv⌕ Search

arXiv subjects

Piet O. Schmidt

Publications and source records attributed to Piet O. Schmidt.

At least 37 records · Page 2Linked to original sources

Coherent photo-thermal noise cancellation in a dual-wavelength optical cavity for narrow-linewidth laser frequency stabilisation

Optical resonators are used for the realisation of ultra-stable frequency lasers. The use of high reflectivity multi-band coatings allows the frequency locking of several lasers of different wavelengths to a single cavity. While the noise processes for single wavelength cavities are well known, the correlation caused by multi-stack coatings has as yet not been analysed experimentally. In our work, we stabilise the frequency of a $729\,$nm and a $1069\,$nm laser to one mirror pair and determine the residual-amplitude modulation (RAM) and photo-thermal noise (PTN). We find correlations in PTN between the two lasers and observe coherent cancellation of PTN for the $1069\,$nm coating. We show that the fractional frequency instability of the $729\,$nm laser is limited by RAM at $1\times10^{-14}$. The instability of the $1069\,$nm laser is at $3\times10^{-15}$ close to the thermal noise limit of $1.5\times10^{-15}$.

physics.optics↗

A low phase noise cavity transmission self-injection locked laser system for atomic physics experiments

Lasers with high spectral purity are indispensable for optical clocks and coherent manipulation of atomic and molecular qubits for applications such as quantum computing and quantum simulation. Stabilisation of the laser to a reference can provide a narrow linewidth and high spectral purity. However, widely-used diode lasers exhibit fast phase noise that prevents high fidelity qubit manipulation. Here we demonstrate a self-injection locked diode laser system utilizing a medium finesse cavity. The cavity not only provides a stable resonance frequency, but at the same time acts as a low-pass filter for phase noise beyond the cavity linewidth of around 100 kHz, resulting in low phase noise from dc to the injection lock limit. We model the expected laser performance and benchmark it using a single trapped $^{40}$Ca$^{+}$-ion as a spectrum analyser. We show that the fast phase noise of the laser at relevant Fourier frequencies of 100 kHz to >2 MHz is suppressed to a noise floor of between -110 dBc/Hz and -120 dBc/Hz, an improvement of 20 to 30 dB over state-of-the-art Pound-Drever-Hall-stabilized extended-cavity diode lasers. This strong suppression avoids incoherent (spurious) spin flips during manipulation of optical qubits and improves laser-driven gates in using diode lasers with applications in quantum logic spectroscopy, quantum simulation and quantum computation.

quant-ph↗

An Optical Atomic Clock Based on a Highly Charged Ion

Optical atomic clocks are the most accurate measurement devices ever constructed and have found many applications in fundamental science and technology. The use of highly charged ions (HCI) as a new class of references for highest accuracy clocks and precision tests of fundamental physics has long been motivated by their extreme atomic properties and reduced sensitivity to perturbations from external electric and magnetic fields compared to singly charged ions or neutral atoms. Here we present the first realisation of this new class of clocks, based on an optical magnetic-dipole transition in Ar$^{13+}$. Its comprehensively evaluated systematic frequency uncertainty of $2.2\times10^{-17}$ is comparable to that of many optical clocks in operation. From clock comparisons we improve by eight and nine orders of magnitude upon the uncertainties for the absolute transition frequency and isotope shift ($^{40}$Ar vs. $^{36}$Ar), respectively. These measurements allow us to probe the largely unexplored quantum electrodynamic nuclear recoil, presented as part of improved calculations of the isotope shift which reduce the uncertainty of previous theory by a factor of three. This work establishes forbidden optical transitions in HCI as references for cutting-edge optical clocks and future high-sensitivity searches for physics beyond the standard model.

physics.atom-ph↗

Cold highly charged ions in a radio-frequency trap with superconducting magnetic shielding

We implement sympathetic cooling of highly charged ions (HCI) by fully enclosing a linear Paul trap within a superconducting radio-frequency resonator. A quantization magnetic field applied while cooling down into the superconducting state remains present in the trap for centuries and external electromagnetic fluctuations are greatly suppressed. A magnetic field decay rate at the 10$^{-10}$ s$^{-1}$ level is found using trapped Doppler-cooled Be$^+$ ions as hyperfine-structure (hfs) qubits. Ramsey interferometry and spin-echo measurements on magnetically-sensitive hfs transitions yield coherence times of >400 ms, showing excellent passive shielding at frequencies down to DC. For sympathetic cooling of HCI, we extract them from an electron beam ion trap (EBIT) and co-crystallize one together with Doppler-cooled Be$^+$ ions. By subsequently ejecting all but one Be$^+$ ions, we prepare single HCI for quantum logic spectroscopy towards frequency metrology and qubit operations with a great variety of HCI species.

physics.atom-ph↗

Phase-stabilized UV light at 267 nm through twofold second harmonic generation

Providing phase stable laser light is important to extend the interrogation time of optical clocks towards many seconds and thus achieve small statistical uncertainties. We report a laser system providing more than 50 uW phase-stabilized UV light at 267.4 nm for an aluminium ion optical clock. The light is generated by frequency-quadrupling a fibre laser at 1069.6 nm in two cascaded non-linear crystals, both in single-pass configuration. In the first stage, a 10 mm long PPLN waveguide crystal converts 1 W fundamental light to more than 0.2 W at 534.8 nm. In the following 50 mm long DKDP crystal, more than 50 uW of light at 267.4 nm are generated. An upper limit for the passive short-term phase stability has been measured by a beat-node measurement with an existing phase-stabilized quadrupling system employing the same source laser. The resulting fractional frequency instability of less than 5 x 10^-17 after 1 s supports lifetime-limited probing of the 27Al^+ clock transition, given a sufficiently stable laser source. A further improved stability of the fourth harmonic light is expected through interferometric path length stabilisation of the pump light by back-reflecting it through the entire setup and correcting for frequency deviations. The in-loop error signal indicates an electronically limited instability of 1 x 10^-18 at 1 s.

physics.optics↗

Multilayer ion trap with three-dimensional microwave circuitry for scalable quantum logic applications

We present a multilayer surface-electrode ion trap with embedded 3D microwave circuitry for implementing entangling quantum logic gates. We discuss the electromagnetic full-wave simulation procedure that has led to the trap design and the characterization of the resulting microwave field-pattern using a single ion as a local field probe. The results agree with simulations within the uncertainty; compared to previous traps, this design reduces detrimental AC Zeeman shifts by three orders of magnitude. The design presented here can be viewed as an entangling gate component in a library for surface-electrode ion traps intended for quantum logic operations.

quant-ph↗

Sensitivity to New Physics of Isotope Shift Studies using the Coronal Lines of Highly Charged Calcium Ions

Promising searches for new physics beyond the current Standard Model (SM) of particle physics are feasible through isotope-shift spectroscopy, which is sensitive to a hypothetical fifth force between the neutrons of the nucleus and the electrons of the shell. Such an interaction would be mediated by a new particle which could in principle be associated with dark matter. In so-called King plots, the mass-scaled frequency shifts of two optical transitions are plotted against each other for a series of isotopes. Subtle deviations from the expected linearity could reveal such a fifth force. Here, we study experimentally and theoretically six transitions in highly charged ions of Ca, an element with five stable isotopes of zero nuclear spin. Some of the transitions are suitable for upcoming high-precision coherent laser spectroscopy and optical clocks. Our results provide a sufficient number of clock transitions for -- in combination with those of singly charged Ca$^+$ -- application of the generalized King plot method. This will allow future high-precision measurements to remove higher-order SM-related nonlinearities and open a new door to yet more sensitive searches for unknown forces and particles.

physics.atom-ph↗

Algorithmic Ground-state Cooling of Weakly-Coupled Oscillators using Quantum Logic

Most ions lack the fast, cycling transitions that are necessary for direct laser cooling. In most cases, they can still be cooled sympathetically through their Coulomb interaction with a second, coolable ion species confined in the same potential. If the charge-to-mass ratios of the two ion types are too mismatched, the cooling of certain motional degrees of freedom becomes difficult. This limits both the achievable fidelity of quantum gates and the spectroscopic accuracy. Here we introduce a novel algorithmic cooling protocol for transferring phonons from poorly- to efficiently-cooled modes. We demonstrate it experimentally by simultaneously bringing two motional modes of a Be$^{+}$-Ar$^{13+}$ mixed Coulomb crystal close to their zero-point energies, despite the weak coupling between the ions. We reach the lowest temperature reported for a highly charged ion, with a residual temperature of only $T\lesssim200~\mathrm{μK}$ in each of the two modes, corresponding to a residual mean motional phonon number of $\langle n \rangle \lesssim 0.4$. Combined with the lowest observed electric field noise in a radiofrequency ion trap, these values enable an optical clock based on a highly charged ion with fractional systematic uncertainty below the $10^{-18}$ level. Our scheme is also applicable to (anti-)protons, molecular ions, macroscopic charged particles, and other highly charged ion species, enabling reliable preparation of their motional quantum ground states in traps.

physics.atom-ph↗

Prospects and challenges for squeezing-enhanced optical atomic clocks

We have investigated the benefits of spin squeezed states for clocks operated with typical Brownian frequency noise-limited laser sources. Based on an analytic model of the closed servo-loop of an optical atomic clock, we can give quantitative predictions on the optimal clock stability for a given dead time and laser noise. Our analytic predictions are in very good agreement with numerical simulations of the closed servo-loop. We find that for usual cyclic Ramsey interrogation of single atomic ensembles with dead time, even with the current most stable lasers spin squeezing can only improve the clock stability for ensembles below a critical atom number of about one thousand in an optical Sr lattice clock. Even with a future improvement of the laser performance by one order of magnitude the critical atom number still remains below 100,000. In contrast, clocks based on smaller, non-scalable ensembles, such as ion clocks, can already benefit from squeezed states with current clock lasers.

quant-ph↗

Initialization of quantum simulators by sympathetic cooling

Simulating computationally intractable many-body problems on a quantum simulator holds great potential to deliver insights into physical, chemical, and biological systems. While the implementation of Hamiltonian dynamics within a quantum simulator has already been demonstrated in many experiments, the problem of initialization of quantum simulators to a suitable quantum state has hitherto remained mostly unsolved. Here, we show that already a single dissipatively driven auxiliary particle can efficiently prepare the quantum simulator in a low-energy state of largely arbitrary Hamiltonians. We demonstrate the scalability of our approach and show that it is robust against unwanted sources of decoherence. While our initialization protocol is largely independent of the physical realization of the simulation device, we provide an implementation example for a trapped ion quantum simulator.

quant-ph↗

Guidelines for developing optical clocks with $10^{-18}$ fractional frequency uncertainty

There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups developing optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trapping, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with $1 \times 10^{-18}$ uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.

physics.atom-ph↗

A cryogenic radio-frequency ion trap for quantum logic spectroscopy of highly charged ions

A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single $^9$Be$^+$ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of the lowest levels of electric field noise published to date. We investigate the magnetic-field noise suppression in cryogenic shields made from segmented copper, the resulting magnetic field stability at the ion position and the resulting coherence time. Using this trap in conjunction with an electron beam ion trap and a deceleration beamline, we have been able to trap single highly charged Ar$^{13+}$ (Ar XIV) ions concurrently with single Be$^+$ ions, a key prerequisite for the first quantum logic spectroscopy of a highly charged ion.

physics.atom-ph↗

Robust optical clock transitions in trapped ions

We present a novel method for engineering an optical clock transition that is robust against external field fluctuations and is able to overcome limits resulting from field inhomogeneities. The technique is based on the application of continuous driving fields to form a pair of dressed states essentially free of all relevant shifts. Specifically, the clock transition is robust to magnetic shifts, quadrupole and other tensor shifts, and amplitude fluctuations of the driving fields. The scheme is applicable to either a single ion or an ensemble of ions, and is relevant for several types of ions, such as $^{40}\mathrm{Ca}^{+}$, $^{88}\mathrm{Sr}^{+}$, $^{138}\mathrm{Ba}^{+}$ and $^{176}\mathrm{Lu}^{+}$. Taking a spherically symmetric Coulomb crystal formed by 400 $^{40}\mathrm{Ca}^{+}$ ions as an example, we show through numerical simulations that the inhomogeneous linewidth of tens of Hertz in such a crystal together with linear Zeeman shifts of order 10~MHz are reduced to form a linewidth of around 1~Hz. We estimate a two-order-of-magnitude reduction in averaging time compared to state-of-the art single ion frequency references, assuming a probe laser fractional instability of $10^{-15}$. Furthermore, a statistical uncertainty reaching $2.9\times 10^{-16}$ in 1~s is estimated for a cascaded clock scheme in which the dynamically decoupled Coulomb crystal clock stabilizes the interrogation laser for an $^{27}\mathrm{Al}^{+}$ clock.

physics.atom-ph↗

Photon Recoil Spectroscopy: Systematic Shifts and Nonclassical Enhancements

In photon recoil spectroscopy, signals are extracted from recoils imparted by the spectroscopy light on the motion of trapped ions as demonstrated by C. Hempel et al., Nature Photonics 7, 630 (2013) and Y. Wan et al., Nature Communications 5, 3096 (2014). The method exploits the exquisite efficiency in the detection of phonons achievable in ion crystals, and is thus particularly suitable for species with broad non-cycling transitions where detection of fluorescence photons is impractical. Here, we develop a theoretical model for the description of photon recoil spectroscopy based on a Fokker-Planck equation for the Wigner function of the phonon mode. Our model correctly explains systematic shifts due to Doppler heating and cooling as observed in the experiment. Furthermore, we investigate quantum metrological schemes for enhancing the spectroscopic sensitivity based on the preparation and detection of nonclassical states of the phonon mode.

quant-ph↗

Motional Fock states for quantum-enhanced amplitude and phase measurements with trapped ions

Non-vanishing fluctuations of the vacuum state are a salient feature of quantum theory. These fluctuations fundamentally limit the precision of quantum sensors. Nowadays, several systems such as optical clocks, gravitational wave detectors, matter-wave interferometers, magnetometers, and optomechanical systems approach measurement sensitivities where the effect of quantum fluctuations sets a fundamental limit, the so-called standard quantum limit (SQL). It has been proposed that the SQL can be overcome by squeezing the vacuum fluctuations. Realizations of this scheme have been demonstrated in various systems. However, protocols based on squeezed vacuum crucially rely on precise control of the relative orientation of the squeezing with respect to the operation imprinting the measured quantity. Lack of control can lead to an amplification of noise and reduces the sensitivity of the device. Here, we experimentally demonstrate a novel quantum metrological paradigm based on phase insensitive Fock states of the motional state of a trapped ion, with applications in frequency metrology and displacement detection. The measurement apparatus is used in two different experimental settings probing non-commuting observables with sensitivities beyond the SQL. In both measurements, classical preparation and detection noise are sufficiently small to preserve the quantum gain in a full metrological protocol.

physics.atom-ph↗

Experimental and theoretical investigation of a multi-mode cooling scheme using multiple EIT resonances

We introduce and demonstrate double-bright electromagnetically induced transparency (D-EIT) cooling as a novel approach to EIT cooling. By involving an additional ground state, two bright states can be shifted individually into resonance for cooling of motional modes of frequencies that may be separated by more than the width of a single EIT cooling resonance. This allows three-dimensional ground state cooling of a $^{40}$Ca$^+$ ion trapped in a linear Paul trap with a single cooling pulse. Measured cooling rates and steady-state mean motional quantum numbers for this D-EIT cooling are compared with those of standard EIT cooling as well as concatenated standard EIT cooling pulses for multi-mode cooling. Experimental results are compared to full density matrix calculations. We observe a failure of the theoretical description within the Lamb-Dicke regime that can be overcome by a time-dependent rate theory. Limitations of the different cooling techniques and possible extensions to multi-ion crystals are discussed.

quant-ph↗

A self-injection locked DBR laser for laser cooling of beryllium ions

We present a simple, robust, narrow-linewidth, frequency-doubled semiconductor laser source suitable for laser cooling and repumping of $^9$Be$^+$ ions. A distributed Bragg reflector (DBR) laser diode operating at 626 nm is self-injection-locked to a frequency doubling cavity via phase-stabilised optical feedback when the laser is resonant with the cavity mode. The short-term laser instability is reduced from the MHz-level to approximately 20 kHz by the injection process, thus eliminating the need for a high-bandwidth feedback loop to suppress the otherwise troublesome high-frequency laser noise. Long-term stability of the laser frequency is achieved by feeding back to the length of the enhancement cavity utilising an electro-optic frequency comb generator to produce a beatnote with a laser that is detuned by 98 GHz. Long-term injection locking and frequency stabilisation via a wavemeter are ensured using automatic relocking algorithms.

physics.ins-det↗

The European Quantum Technologies Roadmap

Within the last two decades, Quantum Technologies (QT) have made tremendous progress, moving from Noble Prize award-winning experiments on quantum physics into a cross-disciplinary field of applied research. Technologies are being developed now that explicitly address individual quantum states and make use of the 'strange' quantum properties, such as superposition and entanglement. The field comprises four domains: Quantum Communication, Quantum Simulation, Quantum Computation, and Quantum Sensing and Metrology. One success factor for the rapid advancement of QT is a well-aligned global research community with a common understanding of the challenges and goals. In Europe, this community has profited from several coordination projects, which have orchestrated the creation of a 150-page QT Roadmap. This article presents an updated summary of this roadmap. Besides sections on the four domains of QT, we have included sections on Quantum Theory and Software, and on Quantum Control, as both are important areas of research that cut across all four domains. Each section, after a short introduction to the domain, gives an overview on its current status and main challenges and then describes the advances in science and technology foreseen for the next ten years and beyond.

quant-ph↗