SearcharxivSearch

arXiv subjects

Piyaphat Phoonthong

Publications and source records attributed to Piyaphat Phoonthong.

2 recordsLinked to original sources

Nuclear spin quenching of the $^2S_{1/2}\rightarrow {^2}F_{7/2} $ electric octupole transition in $^{173}$Yb$^+$

We report the coherent excitation of the highly forbidden $^2S_{1/2} \rightarrow {^2}F_{7/2}$ clock transition in the odd isotope $^{173}\mathrm{Yb}^+$ with nuclear spin $I = 5/2$, and reveal the hyperfine-state-dependent, nuclear spin induced quenching of this transition. The inferred lifetime of the $F_e = 4$ hyperfine state is one order of magnitude shorter than the unperturbed ${^2}F_{7/2}$ clock state of $^{171}\mathrm{Yb}^+$. This reduced lifetime lowers the required optical power for coherent excitation of the clock transition, thereby reducing the AC Stark shift caused by the clock laser. Using a 3-ion Coulomb crystal, we experimentally demonstrate an approximately 20-fold suppression of the AC Stark shift, a critical improvement for the scalability of future multi-ion $\mathrm{Yb}^+$ clocks. Furthermore, we report the $|^2S_{1/2},F_g=3\rangle~\rightarrow~|^2F_{7/2},F_e=6\rangle$ unquenched reference transition frequency as $642.11917656354(43)$ THz, along with the measured hyperfine splitting and calculated quadratic Zeeman sensitivities of the ${^2}F_{7/2}$ clock state. Our results pave the way toward multi-ion optical clocks and quantum computers based on $^{173}\mathrm{Yb}^+$.

physics.atom-ph

Accelerating the Averaging Rate of Atomic Ensemble Clock Stability using Atomic Phase Lock

We experimentally demonstrated that the stability of an atomic clock improves at fastest rate $τ^{-1}$ (where $τ$ is the averaging time) when the phase of a local oscillator is genuinely compared to the continuous phase of many atoms in a single trap (atomic phase lock). For this demonstration, we developed a simple method that repeatedly monitors the atomic phase while retaining its coherence by observing only a portion of the whole ion cloud. Using this new method, we measured the continuous phase over 3 measurement cycles, and thereby improved the stability scaling from $τ^{-1/2}$ to $τ^{-1}$ during the 3 measurement cycles. %Compared with the standard method that initialize phase during each measurement cycle, the long term stability was improved by a factor of $\sqrt{n_{cp}}$ (where $n_{cp}$ is the number of continuous phase measurements). This simple method provides a path by which atomic clocks can approach a quantum projection noise limit, even when the measurement noise is dominated by the technical noise.

quant-ph