Searcharxiv⌕ Search

arXiv subjects

Polina Golland

Publications and source records attributed to Polina Golland.

At least 19 recordsLinked to original sources

Aligning Fetal Anatomy with Kinematic Tree Log-Euclidean PolyRigid Transforms

Automated analysis of articulated bodies is crucial in medical imaging. Existing surface-based models often ignore internal volumetric structures and rely on deformation methods that lack anatomical consistency guarantees. To address this problem, we introduce a differentiable volumetric body model based on the Skinned Multi-Person Linear (SMPL) formulation, driven by a new Kinematic Tree-based Log-Euclidean PolyRigid (KTPolyRigid) transform. KTPolyRigid resolves Lie algebra ambiguities associated with large, non-local articulated motions, and encourages smooth, bijective volumetric mappings. Evaluated on 53 fetal MRI volumes, KTPolyRigid yields deformation fields with significantly fewer folding artifacts. Furthermore, our framework enables robust groupwise image registration and a label-efficient, template-based segmentation of fetal organs. It provides a robust foundation for standardized volumetric analysis of articulated bodies in medical imaging.

cs.CV↗

Equivariant symmetry-aware head pose estimation for fetal MRI

We present E(3)-Pose, a novel fast pose estimation method that jointly and explicitly models rotation equivariance and object symmetry. Our work is motivated by the challenging problem of accounting for fetal head motion during a diagnostic MRI scan. We aim to enable automatic adaptive prescription of diagnostic 2D MRI slices with 6-DoF head pose estimation, supported by rapid low-resolution 3D MRI volumes acquired before each 2D slice. Existing pose estimation methods struggle to generalize to clinical volumes due to pose ambiguities induced by inherent anatomical symmetries, as well as low resolution, noise, and artifacts. In contrast, E(3)-Pose captures anatomical symmetries and rigid pose equivariance by construction, and yields robust estimates of the fetal head pose. Our experiments on publicly available and representative clinical fetal MRI datasets demonstrate the superior robustness and generalization of our method across domains. Crucially, E(3)-Pose achieves state-of-the-art accuracy on clinical MRI volumes, supporting future clinical translation. Our implementation is publicly available at github.com/MedicalVisionGroup/E3-Pose.

cs.CV↗

Rapid patient-specific neural networks for intraoperative X-ray to volume registration

Advanced navigation techniques in image-guided interventions and surgical robotics require the rapid and precise alignment of 3D preoperative volumes (e.g., CT, MRI) to 2D intraoperative images (e.g., X-ray fluoroscopy). However, existing 2D/3D registration methods fail to generalize across the broad spectrum of fluoroscopy-guided procedures: traditional intensity-based optimizers require careful hyperparameter tuning for each subject, while deep learning approaches demand extensive manually labeled datasets and remain constrained to the specific anatomy on which they were trained. To address these limitations, we present xvr, a self-supervised framework that combines patient-specific neural networks with gradient-based optimization for automatic 2D/3D registration. xvr leverages physics-based simulation to generate training data from a patient's own preoperative scan, eliminating the need for manual annotation. We present a foundation model pretrained on thousands of whole-body scans, achieving patient-specific adaptation for any anatomical region in only 5 minutes of finetuning. In the largest evaluation of 2D/3D registration on real fluoroscopy to date, xvr achieves high accuracy in seconds across diverse anatomical structures, imaging modalities, and hospitals, improving upon the accuracy of existing methods by an order of magnitude. xvr makes pan-anatomical 2D/3D rigid registration accessible to broad clinical and research communities through open-source software at https://xvr.csail.mit.edu.

eess.IV↗

Why Invariance is Not Enough for Biomedical Domain Generalization and How to Fix It

We present MaskGen, a theoretically grounded and deliberately simple approach for domain generalization in 3D biomedical image segmentation. Modern segmentation models degrade sharply under shifts in modality, disease severity, clinical sites, and more, limiting their reliable adoption. Existing generalization methods address this using extreme augmentations, hand-engineered domain statistics mixing, or architectural redesigns that add significant implementation overhead while yielding inconsistent performance across biomedical settings. MaskGen instead presents a principled learning strategy with marginal overhead that utilizes both source-domain image intensities and domain-stable foundation model representations to train robust segmentation models. As a result, MaskGen achieves strong gains in both fully supervised and few-shot segmentation across broad clinical shifts in biomedical studies. Unlike prior approaches, MaskGen is architecture- and loss-agnostic, compatible with standard augmentation pipelines, easy to implement, and tackles arbitrary anatomical regions. Its implementation is freely available at https://github.com/sebodiaz/MaskGen.

eess.IV↗

A Unified Deep Learning Framework for Motion Correction in Medical Imaging

Deep learning has shown significant value in medical image registration for motion correction, however, current techniques are either limited by the type and range of motion they can handle, or require iterative inference and/or retraining for new imaging data. To address these limitations, we introduce UniMo, a Unified Motion Correction framework that leverages deep neural networks to correct for various types of motion in medical imaging. UniMo exploits an alternating optimization scheme for a unified loss function to train an integrated model of 1) an equivariant neural network for global rigid motion correction and 2) an encoder-decoder network to correct local deformations. It features a geometric deformation augmenter that 1) enhances the robustness of global motion correction by addressing any local deformations, and 2) generates augmented data to improve the training process. UniMo is a hybrid model that uses both image intensities and shapes to achieve robust performance amid image appearance variations, and, therefore, it generalizes well to various medical imaging modalities without a need for network retraining. We trained and tested UniMo to track motion in fetal magnetic resonance imaging. Then we tested the trained model, without retraining, on various image modalities from three public datasets, including MedMNIST, lung CT, and BraTS. The results show that UniMo surpassed existing motion correction methods in terms of accuracy, and, notably, it enabled one-time training on a single modality while maintaining high stability and adaptability for inference across multiple unseen imaging datasets. By offering a unified solution, UniMo marks a significant advantage in challenging applications with a mixture of bulk motion and local deformations. https://github.com/IntelligentImaging/UNIMO

eess.IV↗

Less is More: Rethinking Few-Shot Learning and Recurrent Neural Nets

The statistical supervised learning framework assumes an input-output set with a joint probability distribution that is reliably represented by the training dataset. The learner is then required to output a prediction rule learned from the training dataset's input-output pairs. In this work, we provide meaningful insights into the asymptotic equipartition property (AEP) \citep{Shannon:1948} in the context of machine learning, and illuminate some of its potential ramifications for few-shot learning. We provide theoretical guarantees for reliable learning under the information-theoretic AEP, and for the generalization error with respect to the sample size. We then focus on a highly efficient recurrent neural net (RNN) framework and propose a reduced-entropy algorithm for few-shot learning. We also propose a mathematical intuition for the RNN as an approximation of a sparse coding solver. We verify the applicability, robustness, and computational efficiency of the proposed approach with image deblurring and optical coherence tomography (OCT) speckle suppression. Our experimental results demonstrate significant potential for improving learning models' sample efficiency, generalization, and time complexity, that can therefore be leveraged for practical real-time applications.

cs.LG↗

Connecting Jensen-Shannon and Kullback-Leibler Divergences: A New Bound for Representation Learning

Mutual Information (MI) is a fundamental measure of statistical dependence widely used in representation learning. While direct optimization of MI via its definition as a Kullback-Leibler divergence (KLD) is often intractable, many recent methods have instead maximized alternative dependence measures, most notably, the Jensen-Shannon divergence (JSD) between joint and product of marginal distributions via discriminative losses. However, the connection between these surrogate objectives and MI remains poorly understood. In this work, we bridge this gap by deriving a new, tight, and tractable lower bound on KLD as a function of JSD in the general case. By specializing this bound to joint and marginal distributions, we demonstrate that maximizing the JSD-based information increases a guaranteed lower bound on mutual information. Furthermore, we revisit the practical implementation of JSD-based objectives and observe that minimizing the cross-entropy loss of a binary classifier trained to distinguish joint from marginal pairs recovers a known variational lower bound on the JSD. Extensive experiments demonstrate that our lower bound is tight when applied to MI estimation. We compared our lower bound to state-of-the-art neural estimators of variational lower bound across a range of established reference scenarios. Our lower bound estimator consistently provides a stable, low-variance estimate of a tight lower bound on MI. We also demonstrate its practical usefulness in the context of the Information Bottleneck framework. Taken together, our results provide new theoretical justifications and strong empirical evidence for using discriminative learning in MI-based representation learning.

cs.LG↗

Volumetrically Consistent Implicit Atlas Learning via Neural Diffeomorphic Flow for Placenta MRI

Establishing dense volumetric correspondences across anatomical shapes is essential for group-level analysis but remains challenging for implicit neural representations. Most existing implicit registration methods rely on supervision near the zero-level set and thus capture only surface correspondences, leaving interior deformations under-constrained. We introduce a volumetrically consistent implicit model that couples reconstruction of signed distance functions (SDFs) with neural diffeomorphic flow to learn a shared canonical template of the placenta. Volumetric regularization, including Jacobian-determinant and biharmonic penalties, suppresses local folding and promotes globally coherent deformations. In the motivating application to placenta MRI, our formulation jointly reconstructs individual placentas, aligns them to a population-derived implicit template, and enables voxel-wise intensity mapping in a unified canonical space. Experiments on in-vivo placenta MRI scans demonstrate improved geometric fidelity and volumetric alignment over surface-based implicit baseline methods, yielding anatomically interpretable and topologically consistent flattening suitable for group analysis.

cs.CV↗

Fast Multi-Stack Slice-to-Volume Reconstruction via Multi-Scale Unrolled Optimization

Fully convolutional networks have become the backbone of modern medical imaging due to their ability to learn multi-scale representations and perform end-to-end inference. Yet their potential for slice-to-volume reconstruction (SVR), the task of jointly estimating 3D anatomy and slice poses from misaligned 2D acquisitions, remains underexplored. We introduce a fast convolutional framework that fuses multiple orthogonal 2D slice stacks to recover coherent 3D structure and refines slice alignment through lightweight model-based optimization. Applied to fetal brain MRI, our approach reconstructs high-quality 3D volumes in under 10s, with 1s slice registration and accuracy on par with state-of-the-art iterative SVR pipelines, offering more than speedup. The framework uses non-rigid displacement fields to represent transformations, generalizing to other SVR problems like fetal body and placental MRI. Additionally, the fast inference time paves the way for real-time, scanner-side volumetric feedback during MRI acquisition.

eess.IV↗

Deep-ER: Deep Learning ECCENTRIC Reconstruction for fast high-resolution neurometabolic imaging

Introduction: Altered neurometabolism is an important pathological mechanism in many neurological diseases and brain cancer, which can be mapped non-invasively by Magnetic Resonance Spectroscopic Imaging (MRSI). Advanced MRSI using non-cartesian compressed-sense acquisition enables fast high-resolution metabolic imaging but has lengthy reconstruction times that limits throughput and needs expert user interaction. Here, we present a robust and efficient Deep Learning reconstruction to obtain high-quality metabolic maps. Methods: Fast high-resolution whole-brain metabolic imaging was performed at 3.4 mm$^3$ isotropic resolution with acquisition times between 4:11-9:21 min:s using ECCENTRIC pulse sequence on a 7T MRI scanner. Data were acquired in a high-resolution phantom and 27 human participants, including 22 healthy volunteers and 5 glioma patients. A deep neural network using recurring interlaced convolutional layers with joint dual-space feature representation was developed for deep learning ECCENTRIC reconstruction (Deep-ER). 21 subjects were used for training and 6 subjects for testing. Deep-ER performance was compared to conventional iterative Total Generalized Variation reconstruction using image and spectral quality metrics. Results: Deep-ER demonstrated 600-fold faster reconstruction than conventional methods, providing improved spatial-spectral quality and metabolite quantification with 12%-45% (P<0.05) higher signal-to-noise and 8%-50% (P<0.05) smaller Cramer-Rao lower bounds. Metabolic images clearly visualize glioma tumor heterogeneity and boundary. Conclusion: Deep-ER provides efficient and robust reconstruction for sparse-sampled MRSI. The accelerated acquisition-reconstruction MRSI is compatible with high-throughput imaging workflow. It is expected that such improved performance will facilitate basic and clinical MRSI applications.

eess.IV↗

PolyPose: Deformable 2D/3D Registration via Polyrigid Transformations

Determining the 3D pose of a patient from a limited set of 2D X-ray images is a critical task in interventional settings. While preoperative volumetric imaging (e.g., CT and MRI) provides precise 3D localization and visualization of anatomical targets, these modalities cannot be acquired during procedures, where fast 2D imaging (X-ray) is used instead. To integrate volumetric guidance into intraoperative procedures, we present PolyPose, a simple and robust method for deformable 2D/3D registration. PolyPose parameterizes complex 3D deformation fields as a composition of rigid transforms, leveraging the biological constraint that individual bones do not bend in typical motion. Unlike existing methods that either assume no inter-joint movement or fail outright in this under-determined setting, our polyrigid formulation enforces anatomically plausible priors that respect the piecewise-rigid nature of human movement. This approach eliminates the need for expensive deformation regularizers that require patient- and procedure-specific hyperparameter optimization. Across extensive experiments on diverse datasets from orthopedic surgery and radiotherapy, we show that this strong inductive bias enables PolyPose to successfully align the patient's preoperative volume to as few as two X-rays, thereby providing crucial 3D guidance in challenging sparse-view and limited-angle settings where current registration methods fail. Additional visualizations, tutorials, and code are available at https://polypose.csail.mit.edu.

cs.CV↗

Robust Fetal Pose Estimation across Gestational Ages via Cross-Population Augmentation

Fetal motion is a critical indicator of neurological development and intrauterine health, yet its quantification remains challenging, particularly at earlier gestational ages (GA). Current methods track fetal motion by predicting the location of annotated landmarks on 3D echo planar imaging (EPI) time-series, primarily in third-trimester fetuses. The predicted landmarks enable simplification of the fetal body for downstream analysis. While these methods perform well within their training age distribution, they consistently fail to generalize to early GAs due to significant anatomical changes in both mother and fetus across gestation, as well as the difficulty of obtaining annotated early GA EPI data. In this work, we develop a cross-population data augmentation framework that enables pose estimation models to robustly generalize to younger GA clinical cohorts using only annotated images from older GA cohorts. Specifically, we introduce a fetal-specific augmentation strategy that simulates the distinct intrauterine environment and fetal positioning of early GAs. Our experiments find that cross-population augmentation yields reduced variability and significant improvements across both older GA and challenging early GA cases. By enabling more reliable pose estimation across gestation, our work potentially facilitates early clinical detection and intervention in challenging 4D fetal imaging settings. Code is available at https://github.com/sebodiaz/cross-population-pose.

cs.CV↗

Fetuses Made Simple: Modeling and Tracking of Fetal Shape and Pose

Analyzing fetal body motion and shape is paramount in prenatal diagnostics and monitoring. Existing methods for fetal MRI analysis mainly rely on anatomical keypoints or volumetric body segmentations. Keypoints simplify body structure to facilitate motion analysis, but may ignore important details of full-body shape. Body segmentations capture complete shape information but complicate temporal analysis due to large non-local fetal movements. To address these limitations, we construct a 3D articulated statistical fetal body model based on the Skinned Multi-Person Linear Model (SMPL). Our algorithm iteratively estimates body pose in the image space and body shape in the canonical pose space. This approach improves robustness to MRI motion artifacts and intensity distortions, and reduces the impact of incomplete surface observations due to challenging fetal poses. We train our model on segmentations and keypoints derived from $19,816$ MRI volumes across $53$ subjects. Our model captures body shape and motion across time series and provides intuitive visualization. Furthermore, it enables automated anthropometric measurements traditionally difficult to obtain from segmentations and keypoints. When tested on unseen fetal body shapes, our method yields a surface alignment error of $3.2$ mm for $3$ mm MRI voxel size. To our knowledge, this represents the first 3D articulated statistical fetal body model, paving the way for enhanced fetal motion and shape analysis in prenatal diagnostics. The code is available at https://github.com/MedicalVisionGroup/fetal-smpl .

cs.CV↗

Calibrating Expressions of Certainty

We present a novel approach to calibrating linguistic expressions of certainty, e.g., "Maybe" and "Likely". Unlike prior work that assigns a single score to each certainty phrase, we model uncertainty as distributions over the simplex to capture their semantics more accurately. To accommodate this new representation of certainty, we generalize existing measures of miscalibration and introduce a novel post-hoc calibration method. Leveraging these tools, we analyze the calibration of both humans (e.g., radiologists) and computational models (e.g., language models) and provide interpretable suggestions to improve their calibration.

cs.CL↗

Spatial regularisation for improved accuracy and interpretability in keypoint-based registration

Unsupervised registration strategies bypass requirements in ground truth transforms or segmentations by optimising similarity metrics between fixed and moved volumes. Among these methods, a recent subclass of approaches based on unsupervised keypoint detection stand out as very promising for interpretability. Specifically, these methods train a network to predict feature maps for fixed and moving images, from which explainable centres of mass are computed to obtain point clouds, that are then aligned in closed-form. However, the features returned by the network often yield spatially diffuse patterns that are hard to interpret, thus undermining the purpose of keypoint-based registration. Here, we propose a three-fold loss to regularise the spatial distribution of the features. First, we use the KL divergence to model features as point spread functions that we interpret as probabilistic keypoints. Then, we sharpen the spatial distributions of these features to increase the precision of the detected landmarks. Finally, we introduce a new repulsive loss across keypoints to encourage spatial diversity. Overall, our loss considerably improves the interpretability of the features, which now correspond to precise and anatomically meaningful landmarks. We demonstrate our three-fold loss in foetal rigid motion tracking and brain MRI affine registration tasks, where it not only outperforms state-of-the-art unsupervised strategies, but also bridges the gap with state-of-the-art supervised methods. Our code is available at https://github.com/BenBillot/spatial_regularisation.

cs.CV↗

Learning General-Purpose Biomedical Volume Representations using Randomized Synthesis

Current volumetric biomedical foundation models struggle to generalize as public 3D datasets are small and do not cover the broad diversity of medical procedures, conditions, anatomical regions, and imaging protocols. We address this by creating a representation learning method that instead anticipates strong domain shifts at training time itself. We first propose a data engine that synthesizes highly variable training samples that would enable generalization to new biomedical contexts. To then train a single 3D network for any voxel-level task, we develop a contrastive learning method that pretrains the network to be stable against nuisance imaging variation simulated by the data engine, a key inductive bias for generalization. This network's features can be used as robust representations of input images for downstream tasks and its weights provide a strong, dataset-agnostic initialization for finetuning on new datasets. As a result, we set new standards across both multimodality registration and few-shot segmentation, a first for any 3D biomedical vision model, all without (pre-)training on any existing dataset of real images.

cs.CV↗

Improving Medical Visual Representations via Radiology Report Generation

Vision-language pretraining has been shown to produce high-quality visual encoders which transfer efficiently to downstream computer vision tasks. Contrastive learning approaches have increasingly been adopted for medical vision language pretraining (MVLP), yet recent developments in generative AI offer new modeling alternatives. This paper introduces RadTex, a CNN-encoder transformer-decoder architecture optimized for radiology. We explore bidirectional captioning as an alternative MVLP strategy and demonstrate that RadTex's captioning pretraining is competitive with established contrastive methods, achieving a CheXpert macro-AUC of 89.4%. Additionally, RadTex's lightweight text decoder not only generates clinically relevant radiology reports (macro-F1 score of 0.349), but also provides targeted, interactive responses, highlighting the utility of bidirectional captioning in advancing medical image analysis.

cs.CV↗

Differentiable Voxel-based X-ray Rendering Improves Sparse-View 3D CBCT Reconstruction

We present DiffVox, a self-supervised framework for Cone-Beam Computed Tomography (CBCT) reconstruction by directly optimizing a voxelgrid representation using physics-based differentiable X-ray rendering. Further, we investigate how the different implementations of the X-ray image formation model in the renderer affect the quality of 3D reconstruction and novel view synthesis. When combined with our regularized voxel-based learning framework, we find that using an exact implementation of the discrete Beer-Lambert law for X-ray attenuation in the renderer outperforms both widely used iterative CBCT reconstruction algorithms and modern neural field approaches, particularly when given only a few input views. As a result, we reconstruct high-fidelity 3D CBCT volumes from fewer X-rays, potentially reducing ionizing radiation exposure and improving diagnostic utility. Our implementation is available at https://github.com/hossein-momeni/DiffVox.

eess.IV↗