SearcharxivSearch

arXiv subjects

Pouya Sharbati

Publications and source records attributed to Pouya Sharbati.

2 recordsLinked to original sources

Zero- to low-field J-spectroscopy with a diamond magnetometer

We report measurements of zero- to ultra-low-field nuclear magnetic resonance (ZULF NMR) signals at frequencies of a few hertz with a diamond-based magnetic sensor. The sensing diamond is a truncated pyramid with 0.18 mm height and a 0.5 mm x 0.5mm base. The minimum stand-off distance is < 1 mm, and the sensor sensitivity is 13 pT/(Hz)^(1/2) at frequencies f above 5 Hz with 1/f-like behavior at lower frequencies. NMR signals were generated via signal amplification by reversible exchange (SABRE) parahydrogen-based hyperpolarization resulting in zero-field signals at 1.7 Hz and 3.4 Hz corresponding to the expected hetero-nuclear J-coupling pattern of acetonitrile. This work demonstrates a magnet-free platform for detecting chemically specific NMR signals at ultra-low frequencies paving the way for portable noninvasive diagnostics in microscopic sample volumes for biomedicine, industrial sensing through metal enclosures, and field-deployable quantum analytical devices.

physics.app-ph

Human Cardiac Measurements with Diamond Magnetometers

We demonstrate direct, non-invasive and non-contact detection of human cardiac magnetic signals using quantum sensors based on nitrogen-vacancy (NV) centers in diamond. Three configurations were employed recording magnetocardiography (MCG) signals in various shielded and unshielded environments. The signals were averaged over a few hundreds up to several thousands of heart beats to detect the MCG traces. The compact room-temperature NV sensors exhibit sensitivities of 6-26 pT/Hz^(1/2) with active sensing volumes below 0.5 mm^3, defining the performance level of the demonstrated MCG measurements. While the present signals are obtained by averaging, this performance already indicates a clear path toward single-shot MCG sensing. To move beyond shielded environments toward practical clinical use, strong noise suppression is required. To this end, we implement NV-based gradiometry and achieve efficient common-mode noise rejection, enabled by the intrinsically small sensing volume of NV sensors. Together, these multi-platform results obtained across diverse magnetic environments provide a solid foundation for translating quantum sensors into human medical diagnostics such as MCG and magnetoencephalography (MEG).

physics.med-ph