Searcharxiv⌕ Search

arXiv subjects

Pradosh Pritam Dash

Publications and source records attributed to Pradosh Pritam Dash.

5 recordsLinked to original sources

Subwavelength registration of skull-compensating acoustic holograms via nonlinear parametric array feedback

Realizing the potential of optimized acoustic holograms for applications like transcranial ultrasound requires sub-wavelength alignment accuracy (less than 1.5 mm at 1 MHz), which is difficult to achieve with current non-MRI optical neuro-navigation methods. To address the critical challenge of alignment, we leverage the parametric array (PA) signal as an alignment surrogate, a highly penetrative, low-frequency difference wave generated by the nonlinear mixing of two primary high-frequency beams. Simulations show that a misaligned skull-compensating lens increases the primary acoustic energy within the skull bone (volumetric energy trapping), which strengthens the nonlinear source of the PA signal. We also tested whether shear-mode conversion in bone contributes: 2D elastic simulations showed only a small (3-5%) increase in shear-type motion with misalignment, and the transmitted ex vivo bursts did not lengthen as a shear path would require. Pseudo-sound and microbubble artifacts were examined and found unlikely to explain the signal, consistent with the PA signal arising from the intrinsic nonlinearity of the bone. Minimizing this PA signal yields a noninvasive real-time feedback mechanism that achieves sub-wavelength alignment accuracy, outperforming standard neuronavigation. Our findings present a robust framework that supports the design of simple, economical, and high-performance transcranial ultrasound systems for high-precision neuro-interventions.

physics.med-ph↗

Differentiable topology optimization for high-fidelity acoustic holography beyond the thin-element approximation

Acoustic holography in the megahertz range can impact applications from manufacturing and non-destructive testing to transcranial ultrasound. Designing lens topologies for complex holograms in the sub-megahertz to low-megahertz regime most relevant to transcranial therapy is difficult because wave propagation through an acoustically thick lens cannot be ignored. Here we show that the heterogeneous angular spectrum approach (HASA), which admits in-plane varying speed-of-sound maps and supports rapid differentiable optimization with the Adam optimizer, can generate three-dimensional lens topologies directly. With it we quantify the failure of the thin-element approximation (TEA) at these frequencies, where lenses enter an acoustically thick regime (thickness L much greater than the wavelength) governed by refractive walk-off, and we introduce a dimensionless refractive walk-off number Nw that defines a frequency-dependent operating regime. Topology optimization outperformed TEA-based design in all 45 configurations tested, with the largest structural gains at or below 1 MHz; for high-numerical-aperture designs the fidelity at 1 MHz matched that at 2 MHz, while structural similarity was highest at 0.5 MHz. The sub-megahertz to low-megahertz window is therefore a favorable operating regime for high-fidelity transcranial holography rather than one to be avoided. Free-field hydrophone measurements of 3D-printed lenses reproduced the designed patterns, and because the framework also accounts for aberration in heterogeneous media, patient-specific lenses corrected skull-induced aberration in simulation and ex vivo experiment, generalized across skull segments, and shaped volumetric beams through the human skull. Together these results provide a framework for designing simple, economical, and high-performance ultrasound systems.

physics.app-ph↗

Virtual-Array Operational Modal Analysis of Rolling Tires Using a Single Tire Cavity Accelerometer

The dynamics of the rolling tire govern structure-borne road noise below 500 Hz. Laser Doppler vibrometry (LDV) is the established laboratory reference for measuring rolling-tire modes. This paper presents a complementary approach that uses a single wireless tire cavity accelerometer (TCA) mounted on the inner liner and a once-per-revolution encoder on the drum of a tire-on-drum rig fitted with a cleat. Because the drum-to-tire diameter ratio (2.74) is non-integer, successive cleat impacts encounter the TCA at different circumferential positions. The TCA's contact-patch signature locates the sensor at each impact within approximately $1^\circ$, and grouping the impact responses by angular position synthesizes a 36-element virtual array from a single 128 s run. Covariance-driven stochastic subspace identification (SSI-COV) is applied using a consensus rule across multiple parameter settings, bootstrap resampling over impacts, and a correction for window-induced damping; the complete signal-processing chain is verified on synthetic data with known modes. For a slick 195/65R15 tire rolling at 30 km/h under a 1334 N load, ten modes between 46 and 193 Hz are robustly identified, exhibiting circumferential wavenumbers from 1 to 5, damping ratios of 2.1--4.2%, and strongly complex mode shapes, with three additional modes identified tentatively. The extracted modes follow the wavenumber ladder of a stationary modal test of the same tire. Requiring no optical access and capturing the full virtual array in a single run, the proposed method is well suited to treaded tires and on-road testing, at the expense of in-tire sensor installation.

physics.app-ph↗

Transcranial FUS Therapy and Monitoring using Nonlinear Acoustics

Focused ultrasound (FUS) offers a promising, non-invasive method for modulating neural activity and delivering therapies deep within the brain with immense clinical potential. However, progress in developing transcranial ultrasound (TUS) for clinical applications has been hindered by several factors. The complexity of the human skull causes focal aberrations and attenuation, thereby presenting a major obstacle to the precise targeting of ultrasound waves. Although phased arrays can correct for these aberrations, their high cost and continuous reliance on magnetic resonance imaging (MRI) pose significant obstacles for widespread academic research and clinical translation. To address these challenges, this thesis proposes an innovative framework for the design, registration, and clinical application of acoustic holograms. First, we introduce a novel frequency-domain topology optimization method that overcomes the breakdown of traditional phase-only designs in the megahertz regime by accounting for volumetric wave-propagation effects, thereby achieving high-fidelity focusing. Second, we present a non-invasive registration strategy that utilizes the nonlinear parametric array (PA) effect to enable precise lens alignment without requiring any imaging modalities, such as MRI. Finally, we demonstrate the utility of this nonlinear parametric array (PA) effect as a tool for monitoring ventricular dilation as a non-invasive proxy for intracranial pressure changes in hydrocephalus. Collectively, these developments provide a path toward accessible, high-precision transcranial ultrasound systems for research and clinical use. In addition, we demonstrate a novel platform for in vitro focused ultrasound neuromodulation that leverages acoustics to advance therapeutic discovery.

physics.med-ph↗

Acoustic Holography in the Megahertz Frequency Range with Optimal Lens Topologies and Nonlinear Acoustic Feedback

Acoustic holography in the megahertz frequency range can impact numerous applications, including manufacturing, non-destructive testing, and transcranial ultrasound. However, designing lens topologies for complex acoustic holograms in the megahertz range poses a significant challenge, as weave propagation effects through the lens cannot be ignored. Here, we show that the inherent ability of heterogeneous angular spectrum approach to incorporate in plane varying speed-of-sound maps and support rapid differentiable optimization of lens thickness profiles can generate lens topologies for high fidelity acoustic holography. Crucially, we show that this framework can also account for wavefront aberrations in the propagation media, providing the opportunity to reconfigure this disruptive technology for high precision neuro-interventions. Our investigations also revealed that low frequency acoustic feedback generated by nonlinear mixing of high frequency waves allows attaining accurate skull-compensating lens alignment and creates the possibility to monitor CSF fluid build-up and removal in hydrocephalus. Together, our findings support the design of simple, economical, and high-performance ultrasound systems.

physics.app-ph↗