SearcharxivSearch

arXiv subjects

Pretesh Patel

Publications and source records attributed to Pretesh Patel.

13 recordsLinked to original sources

Efficient Vision Mamba for MRI Super-Resolution via Hybrid Selective Scanning

Background: High-resolution MRI is critical for diagnosis, but long acquisition times limit clinical use. Super-resolution (SR) can enhance resolution post-scan, yet existing deep learning methods face fidelity-efficiency trade-offs. Purpose: To develop a computationally efficient and accurate deep learning framework for MRI SR that preserves anatomical detail for clinical integration. Materials and Methods: We propose a novel SR framework combining multi-head selective state-space models (MHSSM) with a lightweight channel MLP. The model uses 2D patch extraction with hybrid scanning to capture long-range dependencies. Each MambaFormer block integrates MHSSM, depthwise convolutions, and gated channel mixing. Evaluation used 7T brain T1 MP2RAGE maps (n=142) and 1.5T prostate T2w MRI (n=334). Comparisons included Bicubic interpolation, GANs (CycleGAN, Pix2pix, SPSR), transformers (SwinIR), Mamba (MambaIR), and diffusion models (I2SB, Res-SRDiff). Results: Our model achieved superior performance with exceptional efficiency. For 7T brain data: SSIM=0.951+-0.021, PSNR=26.90+-1.41 dB, LPIPS=0.076+-0.022, GMSD=0.083+-0.017, significantly outperforming all baselines (p<0.001). For prostate data: SSIM=0.770+-0.049, PSNR=27.15+-2.19 dB, LPIPS=0.190+-0.095, GMSD=0.087+-0.013. The framework used only 0.9M parameters and 57 GFLOPs, reducing parameters by 99.8% and computation by 97.5% versus Res-SRDiff, while outperforming SwinIR and MambaIR in accuracy and efficiency. Conclusion: The proposed framework provides an efficient, accurate MRI SR solution, delivering enhanced anatomical detail across datasets. Its low computational demand and state-of-the-art performance show strong potential for clinical translation.

cs.CV

A Digital Twin Framework for Adaptive Treatment Planning in Radiotherapy

The development of a digital twin (DT) framework for fast online adaptive proton therapy planning in prostate stereotactic body radiation therapy (SBRT) with dominant intraprostatic lesion (DIL) boost represents a significant advancement in personalized radiotherapy. This framework integrates deep learning-based multi-atlas deformable image registration, daily patient anatomy updates via cone-beam CT (CBCT), and knowledge-based plan quality evaluation using the ProKnow scoring system to achieve clinical-equivalent plan quality with substantially reduced reoptimization times compared to traditional clinical workflows. Drawing on a database of 43 prior prostate SBRT cases, the DT framework predicts interfractional anatomical variations for new patients and pre-generates multiple probabilistic treatment plans. Upon acquiring daily CBCT, it enables rapid plan reoptimization, achieving an average reoptimization time of 5.5 [2.8, 8.2] minutes, compared to 19.8 [7.9, 31.7] minutes for clinical plans. The DT-based plans yielded a plan quality score of 157.2 [151.6, 162.8], surpassing or matching clinical plans, with superior dose coverage for the DIL (V100: 99.5%) and clinical target volume (CTV V100: 99.8%). Additionally, the framework minimized doses to organs at risk (OARs), achieving bladder V20.8Gy of 11.4 [7.2, 15.6] cc, rectum V23Gy of 0.7 [0.3, 1.1] cc, and urethra D10 of 90.9% [88.6%, 93.2%], aligning with clinical standards. By addressing interfractional variations efficiently, the DT framework enhances treatment precision, reduces OAR toxicity, and supports real-time adaptive radiotherapy. This transformative approach not only streamlines the planning process but also improves clinical outcomes, offering a scalable solution for prostate SBRT with DIL boost and paving the way for broader applications in adaptive proton therapy.

physics.med-ph

Stereotactic Arrhythmia Radioablation for Refractory Ventricular Tachycardia: A Narrative Review and Exploratory Pooled Analysis of Clinical Outcomes and Toxicity

Purpose: Stereotactic arrhythmia radioablation (STAR) is a non-invasive salvage therapy for refractory ventricular tachycardia (VT), especially in patients ineligible for catheter ablation. This narrative review and pooled analysis evaluates the safety, efficacy, and technical characteristics of STAR, integrating preclinical studies, case reports, case series, and clinical trials. Methods and Materials: A comprehensive review identified 86 studies published between 2015 and 2025, including 12 preclinical studies, 49 case reports, 18 case series, and 7 clinical trials. Study-level data were extracted for pooled analysis of 6- and 12-month mortality, VT burden reduction, and grade 3+ acute toxicities. Subgroup analyses were performed by delivery modality, age, left ventricular ejection fraction (LVEF), and cardiomyopathy type. Results: Pooled mortality was 16% (95% CI: 11-20%) at 6 months and 33% (95% CI: 27-38%) at 12 months. VT burden reduction at 6 months averaged 75% (95% CI: 73-77%) but showed substantial heterogeneity (I^2 = 98.8%). Grade 3+ acute toxicities occurred in 7% (95% CI: 4-10%), with heart failure being most common. Subgroup analyses suggested better outcomes in younger patients, those with NICM, and those with higher LVEF. Conclusions: STAR is a promising salvage therapy with favorable acute safety and efficacy. Outcome heterogeneity and inconsistent reporting highlight the need for standardized definitions, dosimetric protocols, and longer-term follow-up. Prospective trials and real-world registries are critical for refining STAR's role in VT management.

physics.med-ph

A Comparative Dosimetric Study of Proton and Photon Therapy in Stereotactic Arrhythmia Radioablation for Ventricular Tachycardia

Purpose: VT is a life-threatening arrhythmia commonly treated with catheter ablation; however, some cases remain refractory to conventional treatment. STAR has emerged as a non-invasive option for such patients. While photon-based STAR has shown efficacy, proton therapy offers potential advantages due to its superior dose conformity and sparing of critical OARs, including the heart itself. This study aims to investigate and compare the dosimetry between proton and photon therapy for VT, focusing on target coverage and OAR sparing. Methods: We performed a retrospective study on a cohort of 34 VT patients who received photon STAR. Proton STAR plans were generated using robust optimization in RayStation to deliver the same prescription dose of 25 Gy in a single fraction while minimizing dose to OARs. Dosimetric metrics, including D99, D95, Dmean, and D0.03cc, were extracted for critical OARs and VAS. Shapiro-Wilk tests were used to assess normality, followed by paired t-tests or Wilcoxon signed-rank tests for statistical comparisons between modalities, with Bonferroni correction applied for multiple comparisons. Results: Proton and photon plans achieved comparable target coverage, with VAS D95 of 24.1 +/- 1.2 Gy vs. 24.7 +/- 1.0 Gy (p=0.294). Proton therapy significantly reduced OAR doses, including heart Dmean (3.6 +/- 1.5 Gy vs. 5.5 +/- 2.0 Gy, p<0.001), lungs Dmean (1.6 +/- 1.5 Gy vs. 2.1 +/- 1.4 Gy, p<0.001), and esophagus Dmean (0.3 +/- 0.6 Gy vs. 1.6 +/- 1.3 Gy, p<0.001), while maintaining optimal target coverage. Conclusion: Proton therapy for STAR demonstrates significant dosimetric advantages in sparing the heart and other critical OARs compared to photon therapy for VT, while maintaining equivalent target coverage. These findings highlight the potential of proton therapy to reduce treatment-related toxicity and improve outcomes for VT patients.

physics.med-ph

Using Modularized Pin Ridge Filter in Proton FLASH Planning for Liver Stereotactic Ablative Body Radiotherapy

We previously developed a FLASH planning framework for streamlined pin-ridge-filter (pin-RF) design, demonstrating its feasibility for single-energy proton FLASH planning. In this study, we refined the pin-RF design for easy assembly using reusable modules, focusing on its application in liver SABR. This framework generates an intermediate IMPT plan and translates it into step widths and thicknesses of pin-RFs for a single-energy FLASH plan. Parameters like energy spacing, monitor unit limit, and spot quantity were adjusted during IMPT planning, resulting in pin-RFs assembled using predefined modules with widths from 1 to 6 mm, each with a WET of 5 mm. This approach was validated on three liver SABR cases. FLASH doses, quantified using the FLASH effectiveness model at 1 to 5 Gy thresholds, were compared to conventional IMPT (IMPT-CONV) doses to assess clinical benefits. The highest demand for 6 mm width modules, moderate for 2-4 mm, and minimal for 1- and 5-mm modules were shown across all cases. At lower dose thresholds, the two-beam case showed significant dose reductions (>23%), while the other two three-beam cases showed moderate reductions (up to 14.7%), indicating the need for higher fractional beam doses for an enhanced FLASH effect. Positive clinical benefits were seen only in the two-beam case at the 5 Gy threshold. At the 1 Gy threshold, the FLASH plan of the two-beam case outperformed its IMPT-CONV plan, reducing dose indicators by up to 28.3%. However, the three-beam cases showed negative clinical benefits at the 1 Gy threshold, with some dose indicators increasing by up to 16% due to lower fractional beam doses and closer beam arrangements. This study evaluated the feasibility of modularizing streamlined pin-RFs in single-energy proton FLASH planning for liver SABR, offering guidance on optimal module composition and strategies to enhance FLASH planning.

physics.med-ph

Adaptive Proton Therapy Using CBCT-Guided Digital Twins

This study aims to develop a digital twin (DT) framework to enhance adaptive proton stereotactic body radiation therapy (SBRT) for prostate cancer. Prostate SBRT has emerged as a leading option for external beam radiotherapy due to its effectiveness and reduced treatment duration. However, interfractional anatomy variations can impact treatment outcomes. This study seeks to address these uncertainties using DT concept, with the goal of improving treatment quality, potentially revolutionizing prostate radiotherapy to offer personalized treatment solutions. Our study presented a pioneering approach that leverages DT technology to enhance adaptive proton SBRT. The framework improves treatment plans by utilizing patient-specific CTV setup uncertainty, which is usually smaller than conventional clinical setups. This research contributes to the ongoing efforts to enhance the efficiency and efficacy of prostate radiotherapy, with ultimate goals of improving patient outcomes and life quality.

physics.med-ph

Diffeomorphic Transformer-based Abdomen MRI-CT Deformable Image Registration

This paper aims to create a deep learning framework that can estimate the deformation vector field (DVF) for directly registering abdominal MRI-CT images. The proposed method assumed a diffeomorphic deformation. By using topology-preserved deformation features extracted from the probabilistic diffeomorphic registration model, abdominal motion can be accurately obtained and utilized for DVF estimation. The model integrated Swin transformers, which have demonstrated superior performance in motion tracking, into the convolutional neural network (CNN) for deformation feature extraction. The model was optimized using a cross-modality image similarity loss and a surface matching loss. To compute the image loss, a modality-independent neighborhood descriptor (MIND) was used between the deformed MRI and CT images. The surface matching loss was determined by measuring the distance between the warped coordinates of the surfaces of contoured structures on the MRI and CT images. The deformed MRI image was assessed against the CT image using the target registration error (TRE), Dice similarity coefficient (DSC), and mean surface distance (MSD) between the deformed contours of the MRI image and manual contours of the CT image. When compared to only rigid registration, DIR with the proposed method resulted in an increase of the mean DSC values of the liver and portal vein from 0.850 and 0.628 to 0.903 and 0.763, a decrease of the mean MSD of the liver from 7.216 mm to 3.232 mm, and a decrease of the TRE from 26.238 mm to 8.492 mm. The proposed deformable image registration method based on a diffeomorphic transformer provides an effective and efficient way to generate an accurate DVF from an MRI-CT image pair of the abdomen. It could be utilized in the current treatment planning workflow for liver radiotherapy.

cs.CV

Assessing Bilateral Neurovascular Bundles Function with Pulsed Wave Doppler Ultrasound: Implications for Reducing Erectile Dysfunction Following Prostate Radiotherapy

This study aims to evaluate the functional status of bilateral neurovascular bundles (NVBs) using pulsed wave Doppler ultrasound in patients undergoing prostate radiotherapy (RT). Sixty-two patients (mean age: 66.1 +/- 7.2 years) underwent transrectal ultrasound scan using a conventional ultrasound scanner, a 7.5 MHz bi-plane probe and a mechanical stepper. The ultrasound protocol comprised 3 steps: 1) 3D B-mode scans of the entire prostate, 2) localization of NVBs using color flow Doppler imaging, and 3) measurement of NVB function using pulsed wave Doppler. Five pulsed Doppler waveform features were extracted: peak systolic velocity (PSV), end-diastolic velocity (EDV), mean velocity (Vm), resistive index (RI), and pulsatile index (PI). In summary, this study presents a Doppler evaluation of NVBs in patients undergoing prostate RT. It highlights substantial differences in Doppler ultrasound waveform features between bilateral NVBs. The proposed ultrasound method may prove valuable as clinicians strive to deliver NVB-sparing RT to preserve sexual function effectively and enhance patients' overall well-being.

physics.med-ph

Synthetic CT Generation from MRI using 3D Transformer-based Denoising Diffusion Model

Magnetic resonance imaging (MRI)-based synthetic computed tomography (sCT) simplifies radiation therapy treatment planning by eliminating the need for CT simulation and error-prone image registration, ultimately reducing patient radiation dose and setup uncertainty. We propose an MRI-to-CT transformer-based denoising diffusion probabilistic model (MC-DDPM) to transform MRI into high-quality sCT to facilitate radiation treatment planning. MC-DDPM implements diffusion processes with a shifted-window transformer network to generate sCT from MRI. The proposed model consists of two processes: a forward process which adds Gaussian noise to real CT scans, and a reverse process in which a shifted-window transformer V-net (Swin-Vnet) denoises the noisy CT scans conditioned on the MRI from the same patient to produce noise-free CT scans. With an optimally trained Swin-Vnet, the reverse diffusion process was used to generate sCT scans matching MRI anatomy. We evaluated the proposed method by generating sCT from MRI on a brain dataset and a prostate dataset. Qualitative evaluation was performed using the mean absolute error (MAE) of Hounsfield unit (HU), peak signal to noise ratio (PSNR), multi-scale Structure Similarity index (MS-SSIM) and normalized cross correlation (NCC) indexes between ground truth CTs and sCTs. MC-DDPM generated brain sCTs with state-of-the-art quantitative results with MAE 43.317 HU, PSNR 27.046 dB, SSIM 0.965, and NCC 0.983. For the prostate dataset, MC-DDPM achieved MAE 59.953 HU, PSNR 26.920 dB, SSIM 0.849, and NCC 0.948. In conclusion, we have developed and validated a novel approach for generating CT images from routine MRIs using a transformer-based DDPM. This model effectively captures the complex relationship between CT and MRI images, allowing for robust and high-quality synthetic CT (sCT) images to be generated in minutes.

eess.IV

Landmark Tracking in Liver US images Using Cascade Convolutional Neural Networks with Long Short-Term Memory

This study proposed a deep learning-based tracking method for ultrasound (US) image-guided radiation therapy. The proposed cascade deep learning model is composed of an attention network, a mask region-based convolutional neural network (mask R-CNN), and a long short-term memory (LSTM) network. The attention network learns a mapping from a US image to a suspected area of landmark motion in order to reduce the search region. The mask R-CNN then produces multiple region-of-interest (ROI) proposals in the reduced region and identifies the proposed landmark via three network heads: bounding box regression, proposal classification, and landmark segmentation. The LSTM network models the temporal relationship among the successive image frames for bounding box regression and proposal classification. To consolidate the final proposal, a selection method is designed according to the similarities between sequential frames. The proposed method was tested on the liver US tracking datasets used in the Medical Image Computing and Computer Assisted Interventions (MICCAI) 2015 challenges, where the landmarks were annotated by three experienced observers to obtain their mean positions. Five-fold cross-validation on the 24 given US sequences with ground truths shows that the mean tracking error for all landmarks is 0.65+/-0.56 mm, and the errors of all landmarks are within 2 mm. We further tested the proposed model on 69 landmarks from the testing dataset that has a similar image pattern to the training pattern, resulting in a mean tracking error of 0.94+/-0.83 mm. Our experimental results have demonstrated the feasibility and accuracy of our proposed method in tracking liver anatomic landmarks using US images, providing a potential solution for real-time liver tracking for active motion management during radiation therapy.

cs.CV

Deformable Image Registration using Unsupervised Deep Learning for CBCT-guided Abdominal Radiotherapy

CBCTs in image-guided radiotherapy provide crucial anatomy information for patient setup and plan evaluation. Longitudinal CBCT image registration could quantify the inter-fractional anatomic changes. The purpose of this study is to propose an unsupervised deep learning based CBCT-CBCT deformable image registration. The proposed deformable registration workflow consists of training and inference stages that share the same feed-forward path through a spatial transformation-based network (STN). The STN consists of a global generative adversarial network (GlobalGAN) and a local GAN (LocalGAN) to predict the coarse- and fine-scale motions, respectively. The network was trained by minimizing the image similarity loss and the deformable vector field (DVF) regularization loss without the supervision of ground truth DVFs. During the inference stage, patches of local DVF were predicted by the trained LocalGAN and fused to form a whole-image DVF. The local whole-image DVF was subsequently combined with the GlobalGAN generated DVF to obtain final DVF. The proposed method was evaluated using 100 fractional CBCTs from 20 abdominal cancer patients in the experiments and 105 fractional CBCTs from a cohort of 21 different abdominal cancer patients in a holdout test. Qualitatively, the registration results show great alignment between the deformed CBCT images and the target CBCT image. Quantitatively, the average target registration error (TRE) calculated on the fiducial markers and manually identified landmarks was 1.91+-1.11 mm. The average mean absolute error (MAE), normalized cross correlation (NCC) between the deformed CBCT and target CBCT were 33.42+-7.48 HU, 0.94+-0.04, respectively. This promising registration method could provide fast and accurate longitudinal CBCT alignment to facilitate inter-fractional anatomic changes analysis and prediction.

eess.IV

Intensity Non-uniformity Correction in MR Imaging Using Residual Cycle Generative Adversarial Network

Purpose: Correcting or reducing the effects of voxel intensity non-uniformity (INU) within a given tissue type is a crucial issue for quantitative MRI image analysis in daily clinical practice. In this study, we present a deep learning-based approach for MRI image INU correction. Method: We developed a residual cycle generative adversarial network (res-cycle GAN), which integrates the residual block concept into a cycle-consistent GAN (cycle-GAN). In cycle-GAN, an inverse transformation was implemented between the INU uncorrected and corrected MRI images to constrain the model through forcing the calculation of both an INU corrected MRI and a synthetic corrected MRI. A fully convolution neural network integrating residual blocks was applied in the generator of cycle-GAN to enhance end-to-end raw MRI to INU corrected MRI transformation. A cohort of 30 abdominal patients with T1-weighted MR INU images and their corrections with a clinically established and commonly used method, namely, N4ITK were used as a pair to evaluate the proposed res-cycle GAN based INU correction algorithm. Quantitatively comparisons were made among the proposed method and other approaches. Result: Our res-cycle GAN based method achieved higher accuracy and better tissue uniformity compared to the other algorithms. Moreover, once the model is well trained, our approach can automatically generate the corrected MR images in a few minutes, eliminating the need for manual setting of parameters. Conclusion: In this study, a deep learning based automatic INU correction method in MRI, namely, res-cycle GAN has been investigated. The results show that learning based methods can achieve promising accuracy, while highly speeding up the correction through avoiding the unintuitive parameter tuning process in N4ITK correction.

physics.med-ph

Fuzzy Inference Systems Optimization

This paper compares various optimization methods for fuzzy inference system optimization. The optimization methods compared are genetic algorithm, particle swarm optimization and simulated annealing. When these techniques were implemented it was observed that the performance of each technique within the fuzzy inference system classification was context dependent.

cs.AI