Searcharxiv⌕ Search

arXiv subjects

Q. Yue

Publications and source records attributed to Q. Yue.

64 records · Page 4Linked to original sources

Limits on light WIMPs from the CDEX-1 experiment with a p-type point-contact germanium detector at the China Jingping Underground Laboratory

We report results of a search for light Dark Matter WIMPs with CDEX-1 experiment at the China Jinping Underground Laboratory, based on 53.9 kg-days of data from a p-type point-contact germanium detector enclosed by a NaI(Tl) crystal scintillator as anti-Compton detector. The event rate and spectrum above the analysis threshold of 475 eVee are consistent with the understood background model. Part of the allowed regions for WIMP-nucleus coherent elastic scattering at WIMP mass of 6-20 GeV are probed and excluded. Independent of interaction channels, this result contradicts the interpretation that the anomalous excesses of the CoGeNT experiment are induced by Dark Matter, since identical detector techniques are used in both experiments.

hep-ex↗

Search for Low-Mass Dark Matter with CsI(Tl) Crystal Detectors

We present a search for low-mass ($\leq 20 GeV/c^{2}$) weakly interacting massive particles(WIMPs), strong candidates of dark matter particles,using the low-background CsI(Tl) detector array of the Korea Invisible Mass Search (KIMS) experiment. With a total data exposure of 24,324.3kg$\cdot$days,we search for WIMP interaction signals produced by nuclei recoiling from WIMP-nuclear elastic scattering with visible energies between 2 and 4keV. The observed energy distribution of candidate events is consistent with null signals, and upper limits of the WIMP-proton spin-independent interaction are set with a 90% confidence level. The observed limit rejects most of the low mass region of parameter space favored by the DAMA annual modulation signal.

astro-ph.CO↗

Measurement of intrinsic radioactive backgrounds from Cs-137 and U/Th chains in CsI(Tl) crystals

The inorganic CsI(Tl) crystal scintillator is a candidate served as an anti-compton detector for China Dark matter EXperiment (CDEX). Studying the intrinsic radiopurity of CsI(Tl) crystal is an issue of major importance. The timing, energy and spatial correlations, as well as the capability of pulse shape discrimination provide powerful methods for the measurement of intrinsic radiopurities. The experimental design, detector performance and event-selection algorithms are described. A total of 359*3 kg-days data from three prototypes of CsI(Tl) crystals were taken at China Jinping underground laboratory where offers a good shielding environment. The contamination levels of internal isotopes from Cs-137, Th-232 and U-238 series, as well as the upper bounds of U-235 series are reported. Identification of the whole alpha8 peaks from U/Th decay chains and derivation of those corresponding quenching factors are achieved.

physics.ins-det↗

Limits on light WIMPs with a germanium detector at 177 eVee threshold at the China Jinping Underground Laboratory

The China Dark Matter Experiment reports results on light WIMP dark matter searches at the China Jinping Underground Laboratory with a germanium detector array with a total mass of 20 g. The physics threshold achieved is 177 eVee ("ee" represents electron equivalent energy) at 50% signal efficiency. With 0.784 kg-days of data, exclusion region on spin-independent coupling with the nucleon is derived, improving over our earlier bounds at WIMP mass less than 4.6 GeV.

hep-ex↗

First results on low-mass WIMP from the CDEX-1 experiment at the China Jinping underground Laboratory

The China Dark matter Experiment collaboration reports the first experimental limit on WIMP dark matter from 14.6 kg-day of data taken with a 994 g p-type point-contact germanium detector at the China Jinping underground Laboratory where the rock overburden is more than 2400 m. The energy threshold achieved was 400 eVee. According to the 14.6 kg-day live data, we placed the limit of N= 1.75 * 10^{-40} cm^{2} at 90% confidence level on the spin-independent cross-section at WIMP mass of 7 GeV before differentiating bulk signals from the surface backgrounds.

hep-ex↗

Low energy fast events from radon progenies at the surface of a CsI(Tl) scintillator

In searches for rare phenomena such as elastic scattering of dark matter particles or neutrinoless double beta decay, alpha decays of Rn222 progenies attached to the surfaces of the detection material have been identified as a serious source of background. In measurements with CsI(Tl) scintillator crystals, we demonstrate that alpha decays of surface contaminants produce fast signals with a characteristic mean-time distribution that is distinct from those of neutron- and gamma-induced events.

astro-ph.CO↗

New Limits on Interactions between Weakly Interacting Massive Particles and Nucleons Obtained with CsI(Tl) Crystal Detectors

New limits are presented on the cross section for Weakly Interacting Massive Particle (WIMP) nucleon scattering in the KIMS CsI(T) detector array at the Yangyang Underground Laboratory. The exposure used for these results is 24524.3 kg\cdotdays. Nuclei recoiling from WIMP interactions are identified by a pulse shape discrimination method. A low energy background due to alpha emitters on the crystal surfaces is identified and taken into account in the analysis. The detected numbers of nuclear recoils are consistent with zero and 90% confidence level upper limits on the WIMP interaction rates are set for electron equivalent energies from 3 keV to 11 keV. The 90% upper limit of NR event rate for 3.6-5.8 keV corresponding to 2-4 keV in NaI(T) is 0.0098 counts/kg/keV/day which is below the annual modulation amplitude reported by DAMA. This is incompatible with interpretations that enhance the modulation amplitude such as inelastic dark matter models. We establish the most stringent cross section limits on spin-dependent WIMP-proton elastic scattering for the WIMP masses greater than 20 GeV/c2.

astro-ph.CO↗

Constraints on Non-Commutative Physics Scale with Neutrino-Electron Scattering

Neutrino-electron scatterings ($ν- e$) are purely leptonic processes with robust Standard Model (SM) predictions. Their measurements can therefore provide constraints to physics beyond SM. Non-commutative (NC) field theories modify space-time commutation relations, and allow neutrino electromagnetic couplings at the tree level. Their contribution to neutrino-electron scattering cross-section was derived. Constraints were placed on the NC scale parameter $Λ_{NC}$ from $ν- e$ experiments with reactor and accelerator neutrinos. The most stringent limit of $Λ_{NC} > 3.3 TeV$ at 95% confidence level improves over the direct bounds from collider experiments.

hep-ph↗

Limits on WIMP-nucleon interactions with CsI(Tl) crystal detectors

The Korea Invisible Mass Search(KIMS) experiment presents new limits on WIMP-nucleon cross section using the data from an exposure of 3409 kgd taken with low background CsI(Tl) crystals at Yangyang underground laboratory. The most stringent limit on the spin dependent interaction for pure proton case is obtained. The DAMA signal region for both spin independent and spin dependent interactions for the WIMP mass higher than 20 GeV/c^2are excluded by the single experiment with crystal scintillators.

astro-ph↗

Effective Dynamic Range in Measurements with Flash Analog-to-Digital Convertor

Flash Analog to Digital Convertor (FADC) is frequently used in nuclear and particle physics experiments, often as the major component in big multi-channel systems. The large data volume makes the optimization of operating parameters necessary. This article reports a study of a method to extend the dynamic range of an 8-bit FADC from the nominal $\rm{2^8}$ value. By comparing the integrated pulse area with that of a reference profile, good energy reconstruction and event identification can be achieved on saturated events from CsI(Tl) crystal scintillators. The effective dynamic range can be extended by at least 4 more bits. The algorithm is generic and is expected to be applicable to other detector systems with FADC readout.

hep-ex↗