SearcharxivSearch

arXiv subjects

Qingling Xia

Publications and source records attributed to Qingling Xia.

3 recordsLinked to original sources

CFSPMNet: Cross-subject Fourier-guided Spatial-Patch Mamba Network for EEG Motor Imagery Decoding in Stroke Patients

Motor imagery electroencephalography (MI-EEG) decoding offers a non-invasive route for post-stroke rehabilitation, but cross-patient use remains difficult because pathological neural reorganization changes task-related EEG dynamics, aperiodic activity, local excitability, cross-regional coordination, and trial-level brain-state context. This makes source-learned MI representations unreliable for unseen patients. To address this problem, we propose CFSPMNet, a cross-patient adaptation framework that models post-stroke MI-EEG as latent neural-state organization. CFSPMNet combines a Fourier-Reorganized State Mamba Network (FRSM) with Shared-Private Prototype Matching (SPPM). FRSM represents each trial as a latent physiological token sequence, reorganizes token states in the Fourier domain, and uses Fourier-derived trial context to guide Mamba state-space propagation. SPPM improves target pseudo-label updating by combining semantic confidence with shared-private physiological consistency, filtering confident but physiologically inconsistent target predictions. Leave-one-subject-out experiments on two stroke MI-EEG datasets show that CFSPMNet outperforms representative CNN-, Transformer-, Mamba-, and adaptation-based baselines, achieving average accuracies of 68.23% on XW-Stroke and 73.33% on 2019-Stroke, with gains of 5.63 and 8.25 percentage points over the strongest competitors. Ablation, sensitivity, feature-alignment, pseudo-label selection, and neurophysiological visualization analyses further support the roles of Fourier-domain token-state reorganization and calibrated pseudo-label updating. These results suggest that latent neural-state modeling can improve rehabilitation-oriented cross-patient BCI decoding. Code is available at https://github.com/wxk1224/CFSPMNet.

cs.LG

PA-TCNet: Pathology-Aware Temporal Calibration with Physiology-Guided Target Refinement for Cross-Subject Motor Imagery EEG Decoding in Stroke Patients

Stroke patient cross-subject electroencephalography (EEG) decoding of motor imagery (MI) brain-computer interface (BCI) is essential for motor rehabilitation, yet lesion-related abnormal temporal dynamics and pronounced inter-patient heterogeneity often undermine generalization. Existing adaptation methods are easily misled by pathological slow-wave activity and unstable target-domain pseudo-labels. To address this challenge, we propose PA-TCNet, a pathology-aware temporal calibration framework with physiology-guided target refinement for stroke motor imagery decoding. PA-TCNet integrates two coordinated components. The Pathology-aware Rhythmic State Mamba (PRSM) module decomposes EEG spatiotemporal features into slowly varying rhythmic context and fast transient perturbations, injecting the fused pathological context into selective state propagation to more effectively capture abnormal temporal dynamics. The Physiology-Guided Target Calibration (PGTC) module constructs source-domain sensorimotor region-of-interest templates, imposing physiological consistency constraints and dynamically refining target-domain pseudo-labels, thereby improving adaptation reliability. Leave-one-subject-out experiments on two independent stroke EEG datasets, XW-Stroke and 2019-Stroke, yielded mean accuracies of 66.56\% and 72.75\%, respectively, outperforming state-of-the-art baselines. These results indicate that jointly modeling pathological temporal dynamics and physiology-constrained pseudo-supervision can provide more robust cross-subject initialization for personalized post-stroke MI-BCI rehabilitation. The implemented code is available at https://github.com/wxk1224/PA-TCNet.

cs.CV

TFCDiff: Robust ECG Denoising via Time-Frequency Complementary Diffusion

Ambulatory electrocardiogram (ECG) readings are prone to mixed noise from physical activities, including baseline wander (BW), muscle artifact (MA), and electrode motion artifact (EM). Developing a method to remove such complex noise and reconstruct high-fidelity signals is clinically valuable for diagnostic accuracy. However, denoising of multi-beat ECG segments remains understudied and poses technical challenges. To address this, we propose Time-Frequency Complementary Diffusion (TFCDiff), a novel approach that operates in the Discrete Cosine Transform (DCT) domain and uses the DCT coefficients of noisy signals as conditioning input. To refine waveform details, we incorporate Temporal Feature Enhancement Mechanism (TFEM) to reinforce temporal representations and preserve key physiological information. Comparative experiments on a synthesized dataset demonstrate that TFCDiff achieves state-of-the-art performance across five evaluation metrics. Furthermore, TFCDiff shows superior generalization on the unseen SimEMG Database, outperforming all benchmark models. Notably, TFCDiff processes raw 10-second sequences and maintains robustness under flexible random mixed noise (fRMN), enabling plug-and-play deployment in wearable ECG monitors for high-motion scenarios. Source code is available at https://github.com/Miroircivil/TFCDiff.

eess.SP