SearcharxivSearch

arXiv subjects

Qiuli Zhang

Publications and source records attributed to Qiuli Zhang.

2 recordsLinked to original sources

Simulation Study on the Discrimination of $0\nu\beta\beta$ Events from Single-Electron Events Using Orthogonal-Strip HPGe Detectors

Neutrinoless double beta decay ($0\nu\beta\beta$) offers a sensitive probe of neutrino mass and its Majorana nature. Orthogonal-strip high-purity germanium (HPGe) detectors with high spatial resolution provide a promising approach for distinguishing $0\nu\beta\beta$ events from single-electron backgrounds. In this work, a simulation framework was developed to evaluate the discrimination performance of these detectors. The framework combined Geant4 simulations with a hybrid numerical-analytical approach to model charge cloud dynamics. A dual-branch convolutional neural network (CNN) was implemented to extract topological features for event classification. The impact of detector geometry on discrimination performance was quantitatively assessed. For a fixed crystal thickness of 15 mm, the background rejection efficiency decreased from 79.5\% to 59.0\% as the strip pitch increased from 0.1 mm to 0.5 mm. For a strip pitch of 0.25 mm, a crystal thickness of 20 mm was found to be optimal, balancing full-energy peak (FEP) efficiency with discrimination capability. These results demonstrate that orthogonal-strip HPGe detectors can effectively suppress single-electron backgrounds, and provide quantitative guidance for detector design in $^{76}$Ge $0\nu\beta\beta$ decay searches.

physics.ins-det

Three-dimensional position reconstruction of orthogonal-strip planar high-purity germanium detectors using maximum likelihood estimation

Orthogonal-strip planar high-purity germanium (HPGe) detectors can reconstruct three-dimensional (3D) positions of photon interactions through analysis of parameters extracted from multiple charge signals. The conventional method independently reconstructs positions in each dimension using amplitude-based parameters, leading to noise sensitivity and systematic biases. In this study, we propose a multi-parameter-joint reconstruction method based on maximum likelihood estimation (MLE) which establishes a mapping between pulse shape parameters and corresponding 3D positions. To mitigate the effects of electronic noise, we employ integral-based parameters. The reconstruction performance was evaluated using pulse shape simulations. For 100 keV photons under 1 keV root-mean-square (RMS) electronic noise, the maximum Z reconstruction bias was reduced from 0.4 mm to 0.02 mm in the central region and from 2 mm to 0.15 mm near the electrodes. The maximum reconstruction bias in the X/Y directions was reduced from 0.4 mm to 0.016 mm. Furthermore, the use of integral-based parameters mitigated the rapid degradation of resolution under high-noise conditions. The achieved position resolution ranged from 0.07 mm to 0.16 mm in the Z directions and from 0.07 mm to 0.44 mm in the X/Y direction. This method offers a promising approach to 3D position reconstruction with HPGe detectors for applications such as medical imaging and gamma-ray astronomy.

physics.ins-det