SearcharxivSearch

arXiv subjects

Qiuwen Wu

Publications and source records attributed to Qiuwen Wu.

7 recordsLinked to original sources

Multi-Catheter Digitization in Brachytherapy via Few-Shot Synthetic-to-Real Learning and Structure-Aware Tracking

Accurate catheter digitization in CT-guided interstitial brachytherapy is a critical but time-consuming task, especially for complex implant configurations. We developed a data-efficient, physics-guided framework for automated multi-catheter digitization with minimal clinical annotation. The pipeline consists of two stages. First, an implant region-aware network was pretrained on synthetic CT volumes with simulated metallic signatures and then fine-tuned using only 10 clinical cases. Second, a structure-aware reconstruction module combined a direction-constrained 3D Hough transform with synchronous physics-constrained inward tracking to separate adherent catheter trajectories. The method was evaluated by patient-level five-fold cross-validation on 203 treatment fractions from 38 patients. The fine-tuned network achieved an HD95 of 0.853 +/- 0.362 mm. End-to-end evaluation yielded an F1 score of 0.891 +/- 0.178, with shaft and tip errors of 0.334 +/- 0.367 mm and 0.896 +/- 0.680 mm, respectively. In cases with severe catheter adhesion, the tracking F1 score remained 0.843 +/- 0.190. The complete workflow required approximately 11.6 s per case. These results indicate that combining few-shot synthetic-to-real learning with physics-guided structural tracking can provide robust and efficient multi-catheter digitization for time-sensitive clinical workflows.

physics.med-ph

Multi-needle Localization for Pelvic Seed Implant Brachytherapy based on Tip-handle Detection and Matching

Accurate multi-needle localization in intraoperative CT images is crucial for optimizing seed placement in pelvic seed implant brachytherapy. However, this task is challenging due to poor image contrast and needle adhesion. This paper presents a novel approach that reframes needle localization as a tip-handle detection and matching problem to overcome these difficulties. An anchor-free network, based on HRNet, is proposed to extract multi-scale features and accurately detect needle tips and handles by predicting their centers and orientations using decoupled branches for heatmap regression and polar angle prediction. To associate detected tips and handles into individual needles, a greedy matching and merging (GMM) method designed to solve the unbalanced assignment problem with constraints (UAP-C) is presented. The GMM method iteratively selects the most probable tip-handle pairs and merges them based on a distance metric to reconstruct 3D needle paths. Evaluated on a dataset of 100 patients, the proposed method demonstrates superior performance, achieving higher precision and F1 score compared to a segmentation-based method utilizing the nnUNet model,thereby offering a more robust and accurate solution for needle localization in complex clinical scenarios.

cs.CV

Zero-Shot Large Language Model Agents for Fully Automated Radiotherapy Treatment Planning

Radiation therapy treatment planning is an iterative, expertise-dependent process, and the growing burden of cancer cases has made reliance on manual planning increasingly unsustainable, underscoring the need for automation. In this study, we propose a workflow that leverages a large language model (LLM)-based agent to navigate inverse treatment planning for intensity-modulated radiation therapy (IMRT). The LLM agent was implemented to directly interact with a clinical treatment planning system (TPS) to iteratively extract intermediate plan states and propose new constraint values to guide inverse optimization. The agent's decision-making process is informed by current observations and previous optimization attempts and evaluations, allowing for dynamic strategy refinement. The planning process was performed in a zero-shot inference setting, where the LLM operated without prior exposure to manually generated treatment plans and was utilized without any fine-tuning or task-specific training. The LLM-generated plans were evaluated on twenty head-and-neck cancer cases against clinical manual plans, with key dosimetric endpoints analyzed and reported. The LLM-generated plans achieved comparable organ-at-risk (OAR) sparing relative to clinical plans while demonstrating improved hot spot control (Dmax: 106.5% vs. 108.8%) and superior conformity (conformity index: 1.18 vs. 1.39 for boost PTV; 1.82 vs. 1.88 for primary PTV). This study demonstrates the feasibility of a zero-shot, LLM-driven workflow for automated IMRT treatment planning in a commercial TPS. The proposed approach provides a generalizable and clinically applicable solution that could reduce planning variability and support broader adoption of AI-based planning strategies.

physics.med-ph

An Iterative LLM Framework for SIBT utilizing RAG-based Adaptive Weight Optimization

Seed implant brachytherapy (SIBT) is an effective cancer treatment modality; however, clinical planning often relies on manual adjustment of objective function weights, leading to inefficiencies and suboptimal results. This study proposes an adaptive weight optimization framework for SIBT planning, driven by large language models (LLMs). A locally deployed DeepSeek-R1 LLM is integrated with an automatic planning algorithm in an iterative loop. Starting with fixed weights, the LLM evaluates plan quality and recommends new weights in the next iteration. This process continues until convergence criteria are met, after which the LLM conducts a comprehensive evaluation to identify the optimal plan. A clinical knowledge base, constructed and queried via retrieval-augmented generation (RAG), enhances the model's domain-specific reasoning. The proposed method was validated on 23 patient cases, showing that the LLM-assisted approach produces plans that are comparable to or exceeding clinically approved and fixed-weight plans, in terms of dose homogeneity for the clinical target volume (CTV) and sparing of organs at risk (OARs). The study demonstrates the potential use of LLMs in SIBT planning automation.

physics.med-ph

An Artificial Intelligence-Driven Agent for Real-Time Head-and-Neck IMRT Plan Generation using Conditional Generative Adversarial Network (cGAN)

Purpose: To develop an Artificial Intelligence (AI) agent for fully-automated rapid head and neck (H&N) IMRT plan generation without time-consuming inverse planning.$$$$ Methods: This AI agent was trained using a conditional Generative Adversarial Network architecture. The generator, PyraNet, is a novel Deep Learning network that implements 28 classic ResNet blocks in pyramid-like concatenations. The discriminator is a customized 4-layer DenseNet. The AI agent first generates customized 2D projections at 9 template beam angles from 3D CT volume and structures of a patient. These projections are then stacked as 4D inputs of PyraNet, from which 9 radiation fluence maps are generated simultaneously. Finally, the predicted fluence maps are imported into a commercial treatment planning system (TPS) for plan integrity checks. The AI agent was built and tested upon 231 oropharyngeal plans from a TPS plan library. Only the primary plans in the sequential boost regime were studied. A customized Harr wavelet loss was adopted for fluence map comparison. Isodose distributions in test AI plans and TPS plans were qualitatively evaluated. Key dosimetric metrics were statistically compared.$$$$ Results: All test AI plans were successfully generated. Isodose gradients outside of PTV in AI plans were comparable with TPS plans. After PTV coverage normalization, $D_{mean}$ of parotids and oral cavity in AI plans and TPS plans were comparable without statistical significance. AI plans achieved comparable $D_{max}$ at 0.01cc of brainstem and cord+5mm without clinically relevant differences, but body $D_{max}$ was higher than the TPS plan results. The AI agent needs ~3s per case to predict fluence maps.$$$$ Conclusions: The developed AI agent can generate H&N IMRT plans with satisfying dosimetry quality. With rapid and fully automated implementation, it holds great potential for clinical applications.

physics.med-ph

An interpretable planning bot for pancreas stereotactic body radiation therapy

Pancreas stereotactic body radiotherapy treatment planning requires planners to make sequential, time consuming interactions with the treatment planning system (TPS) to reach the optimal dose distribution. We seek to develop a reinforcement learning (RL)-based planning bot to systematically address complex tradeoffs and achieve high plan quality consistently and efficiently. The focus of pancreas SBRT planning is finding a balance between organs-at-risk sparing and planning target volume (PTV) coverage. Planners evaluate dose distributions and make planning adjustments to optimize PTV coverage while adhering to OAR dose constraints. We have formulated such interactions between the planner and the TPS into a finite-horizon RL model. First, planning status features are evaluated based on human planner experience and defined as planning states. Second, planning actions are defined to represent steps that planners would commonly implement to address different planning needs. Finally, we have derived a reward system based on an objective function guided by physician-assigned constraints. The planning bot trained itself with 48 plans augmented from 16 previously treated patients and generated plans for 24 cases in a separate validation set. All 24 bot-generated plans achieve similar PTV coverages compared to clinical plans while satisfying all clinical planning constraints. Moreover, the knowledge learned by the bot can be visualized and interpreted as consistent with human planning knowledge, and the knowledge maps learned in separate training sessions are consistent, indicating reproducibility of the learning process.

physics.med-ph

Algorithm and performance of a clinical IMRT beam-angle optimization system

This paper describes the algorithm and examines the performance of an IMRT beam-angle optimization (BAO) system. In this algorithm successive sets of beam angles are selected from a set of predefined directions using a fast simulated annealing (FSA) algorithm. An IMRT beam-profile optimization is performed on each generated set of beams. The IMRT optimization is accelerated by using a fast dose calculation method that utilizes a precomputed dose kernel. A compact kernel is constructed for each of the predefined beams prior to starting the FSA algorithm. The IMRT optimizations during the BAO are then performed using these kernels in a fast dose calculation engine. This technique allows the IMRT optimization to be performed more than two orders of magnitude faster than a similar optimization that uses a convolution dose calculation engine.

physics.med-ph