SearcharxivSearch

arXiv subjects

Queenie Chan

Publications and source records attributed to Queenie Chan.

7 recordsLinked to original sources

Utilizing 3D Fast Spin Echo Anatomical Imaging to Reduce the Number of Contrast Preparations in $T_{1\rho}$ Quantification of Knee Cartilage Using Learning-Based Methods

Purpose: To propose and evaluate an accelerated $T_{1\rho}$ quantification method that combines $T_{1\rho}$-weighted fast spin echo (FSE) images and proton density (PD)-weighted anatomical FSE images, leveraging deep learning models for $T_{1\rho}$ mapping. The goal is to reduce scan time and facilitate integration into routine clinical workflows for osteoarthritis (OA) assessment. Methods: This retrospective study utilized MRI data from 40 participants (30 OA patients and 10 healthy volunteers). A volume of PD-weighted anatomical FSE images and a volume of $T_{1\rho}$-weighted images acquired at a non-zero spin-lock time were used as input to train deep learning models, including a 2D U-Net and a multi-layer perceptron (MLP). $T_{1\rho}$ maps generated by these models were compared with ground truth maps derived from a traditional non-linear least squares (NLLS) fitting method using four $T_{1\rho}$-weighted images. Evaluation metrics included mean absolute error (MAE), mean absolute percentage error (MAPE), regional error (RE), and regional percentage error (RPE). Results: Deep learning models achieved RPEs below 5% across all evaluated scenarios, outperforming NLLS methods, especially in low signal-to-noise conditions. The best results were obtained using the 2D U-Net, which effectively leveraged spatial information for accurate $T_{1\rho}$ fitting. The proposed method demonstrated compatibility with shorter TSLs, alleviating RF hardware and specific absorption rate (SAR) limitations. Conclusion: The proposed approach enables efficient $T_{1\rho}$ mapping using PD-weighted anatomical images, reducing scan time while maintaining clinical standards. This method has the potential to facilitate the integration of quantitative MRI techniques into routine clinical practice, benefiting OA diagnosis and monitoring.

eess.IV

A Systematic Post-Processing Approach for Quantitative $T_{1\rho}$ Imaging of Knee Articular Cartilage

Objective: To establish an automated pipeline for post-processing of quantitative spin-lattice relaxation time constant in the rotating frame ($T_{1\rho}$) imaging of knee articular cartilage. Design: The proposed post-processing pipeline commences with an image standardisation procedure, followed by deep learning-based segmentation to generate cartilage masks. The articular cartilage is then automatically parcellated into 20 subregions, where $T_{1\rho}$ quantification is performed. The proposed pipeline was retrospectively validated on a dataset comprising knee $T_{1\rho}$ images of 10 healthy volunteers and 30 patients with knee osteoarthritis. Three experiments were conducted, namely an assessment of segmentation model performance (using Dice similarity coefficients, DSCs); an evaluation of the impact of standardisation; and a test of $T_{1\rho}$ quantification accuracy (using paired t-tests; root-mean-square deviations, RMSDs; and coefficients of variance of RMSDs, $CV_{RMSD}$). Statistical significance was set as p<0.05. Results: There was a substantial agreement between the subregional $T_{1\rho}$ quantification from the model-predicted masks and those from the manual segmentation labels. In patients, 17 of 20 subregions, and in healthy volunteers, 18 out of 20 subregions, demonstrated no significant difference between predicted and reference $T_{1\rho}$ quantifications. Average RMSDs were 0.79 ms for patients and 0.56 ms for healthy volunteers, while average $CV_{RMSD}$ were 1.97% and 1.38% for patients and healthy volunteers. Bland-Altman plots showed negligible bias across all subregions for patients and healthy volunteers. Conclusion: The proposed pipeline can perform automatic and reliable post-processing of quantitative $T_{1\rho}$ images of knee articular cartilage.

eess.IV

Chemical Shift Encoding based Double Bonds Quantification in Triglycerides using Deep Image Prior

Fatty acid can potentially serve as biomarker for evaluating metabolic disorder and inflammation condition, and quantifying the double bonds is the key for revealing fatty acid information. This study presents an assessment of a deep learning approach utilizing Deep Image Prior (DIP) for the quantification of double bonds and methylene-interrupted double bonds of triglyceride derived from chemical-shift encoded multi-echo gradient echo images, all achieved without the necessity for network training. The methodology implemented a cost function grounded in signal constraints to continually refine the neural network's parameters on a single slice of images through iterative processes. Validation procedures encompassed both phantom experiments and in-vivo scans. The outcomes evidenced a concordance between the quantified values and the established reference standards, notably exemplified by a Pearson correlation coefficient of 0.96 (p = 0.0005) derived from the phantom experiments. The results in water-oil phantom also demonstrate the quantification reliability of the DIP method under the condition of having a relatively low-fat signal. Furthermore, the in-vivo assessments showcased the method's competency by showcasing consistent quantification results that closely mirrored previously published findings concerning subcutaneous fat. In summary, the study underscores the potential of Deep Image Prior in enabling the quantification of double bonds and methylene-interrupted double bonds from chemical-shift encoded multi-echo magnetic resonance imaging (MRI) data, suggesting potential avenues for future research and clinical applications in the field.

physics.med-ph

An Uncertainty Aided Framework for Learning based Liver $T_1ρ$ Mapping and Analysis

Objective: Quantitative $T_1ρ$ imaging has potential for assessment of biochemical alterations of liver pathologies. Deep learning methods have been employed to accelerate quantitative $T_1ρ$ imaging. To employ artificial intelligence-based quantitative imaging methods in complicated clinical environment, it is valuable to estimate the uncertainty of the predicated $T_1ρ$ values to provide the confidence level of the quantification results. The uncertainty should also be utilized to aid the post-hoc quantitative analysis and model learning tasks. Approach: To address this need, we propose a parametric map refinement approach for learning-based $T_1ρ$ mapping and train the model in a probabilistic way to model the uncertainty. We also propose to utilize the uncertainty map to spatially weight the training of an improved $T_1ρ$ mapping network to further improve the mapping performance and to remove pixels with unreliable $T_1ρ$ values in the region of interest. The framework was tested on a dataset of 51 patients with different liver fibrosis stages. Main results: Our results indicate that the learning-based map refinement method leads to a relative mapping error of less than 3% and provides uncertainty estimation simultaneously. The estimated uncertainty reflects the actual error level, and it can be used to further reduce relative $T_1ρ$ mapping error to 2.60% as well as removing unreliable pixels in the region of interest effectively. Significance: Our studies demonstrate the proposed approach has potential to provide a learning-based quantitative MRI system for trustworthy $T_1ρ$ mapping of the liver.

physics.med-ph

Uncertainty-weighted Multi-tasking for $T_{1ρ}$ and T$_2$ Mapping in the Liver with Self-supervised Learning

Multi-parametric mapping of MRI relaxations in liver has the potential of revealing pathological information of the liver. A self-supervised learning based multi-parametric mapping method is proposed to map T$T_{1ρ}$ and T$_2$ simultaneously, by utilising the relaxation constraint in the learning process. Data noise of different mapping tasks is utilised to make the model uncertainty-aware, which adaptively weight different mapping tasks during learning. The method was examined on a dataset of 51 patients with non-alcoholic fatter liver disease. Results showed that the proposed method can produce comparable parametric maps to the traditional multi-contrast pixel wise fitting method, with a reduced number of images and less computation time. The uncertainty weighting also improves the model performance. It has the potential of accelerating MRI quantitative imaging.

physics.med-ph

Uncertainty-Aware Self-supervised Neural Network for Liver $T_{1ρ}$ Mapping with Relaxation Constraint

$T_{1ρ}$ mapping is a promising quantitative MRI technique for the non-invasive assessment of tissue properties. Learning-based approaches can map $T_{1ρ}$ from a reduced number of $T_{1ρ}$ weighted images, but requires significant amounts of high quality training data. Moreover, existing methods do not provide the confidence level of the $T_{1ρ}$ estimation. To address these problems, we proposed a self-supervised learning neural network that learns a $T_{1ρ}$ mapping using the relaxation constraint in the learning process. Epistemic uncertainty and aleatoric uncertainty are modelled for the $T_{1ρ}$ quantification network to provide a Bayesian confidence estimation of the $T_{1ρ}$ mapping. The uncertainty estimation can also regularize the model to prevent it from learning imperfect data. We conducted experiments on $T_{1ρ}$ data collected from 52 patients with non-alcoholic fatty liver disease. The results showed that our method outperformed the existing methods for $T_{1ρ}$ quantification of the liver using as few as two $T_{1ρ}$-weighted images. Our uncertainty estimation provided a feasible way of modelling the confidence of the self-supervised learning based $T_{1ρ}$ estimation, which is consistent with the reality in liver $T_{1ρ}$ imaging.

q-bio.TO

Improved liver T1rho measurement precision with a breathhold black blood single shot fast spin echo acquisition: a validation study in healthy volunteers

Purpose: To explore the usability and normal T1rho value of liver parenchyma with a novel single breathhold black blood single shot fast spin echo acquisition based liver imaging sequence. Materials and Methods: In total 19 health subjects (10 males, 9 females; mean age: 37.4 yrs; range: 23-54 yrs) participated in the study. 11 subjects had liver scanned twice in the same session to access scan-rescan repeatability. 12 subjects had liver scanned twice in two sessions with 7-10 days' interval to access scan-rescan reproducibility. MR was performed with a 3.0 T scanner with dual transmitter. The MR sequence allows simultaneous acquisition of 4 spin lock times (TSLs: 0ms, 10 ms, 30 ms, 50ms) in 10 second. Inherent black blood effect of fast spin echo and double inversion recovery were utilized to achieve blood signal suppression. Results: The technique demonstrated good image quality and minimal artifacts. For liver parenchyma, Bland-Altman plot showed the scan-rescan repeatability mean difference was 0.025 ms (95% limits of agreement: -1.163 to 1.213 ms), and intraclass correlation coefficient (ICC) was 0.977. The scan-rescan reproducibility mean difference was -0.075 ms (95% limits of agreement: -3.280 to 3.310 ms), and ICC was 0.820 which is better than the ICC of 0.764 of a previous bright blood multi-breath hold gradient echo acquisition technique. The liver T1rho value was 39.9 +/- 2.4 ms (range: 36.1 - 44.2 ms), which is lower than the value of 42.8=/-2.1 ms acquired with the previous bright blood technique. Conclusion: This study validated the application of a single breathhold black blood single shot fast spin echo acquisition based for human liver T1rho imaging. The lower liver parenchyma T1rho value and higher scan rescan reproducibility may improve of the sensitivity of this technique.

q-bio.TO