SearcharxivSearch

arXiv subjects

Quentin Diot

Publications and source records attributed to Quentin Diot.

4 recordsLinked to original sources

Dosimetric and Deformation Effects of Image-Guided Interventions during Stereotactic Body Radiation Therapy of the Prostate using an Endorectal Balloon

During Stereotactic Body Radiotherapy (SBRT) for the treatment of prostate cancer, an inflatable endorectal balloon (ERB) may be used to reduce motion of the target and reduce the dose to the posterior rectal wall. This work assessed the dosimetric impact of manual interventions on ERB position in patients receiving prostate SBRT and investigated the impact of ERB interventions on prostate shape. Daily kilovoltage (kV) cone-beam computed tomography (CBCT) imaging was performed to localize the PTV, and an automated fusion with the planning images yielded displacements required for PTV re-localization. When the ERB volume and/or position were judged to yield inaccurate repositioning, manual adjustment (ERB re-inflation and/or repositioning) was performed. Based on all 59 CBCT image sets acquired, a deformable registration algorithm was used to determine the dose received by, displacement of, and deformation of the prostate, bladder, and anterior rectal wall. This dose tracking methodology was applied to images taken before and after manual adjustment of the ERB (intervention), and the delivered dose was compared to that which would have been delivered in the absence of intervention. Interventions occurred in 24 out of 35 (69%) of the treated fractions. The direct effect of these interventions was an increase in the prostate radiation dose that included 95% of the PTV (D95) and an increase in prostate coverage. Additionally, ERB interventions reduced prostate deformation in the anterior-posterior (AP) direction, reduced errors in the sagittal rotation of the prostate, and increased the similarity in shape of the prostate to the radiotherapy plan. Image-guided interventions in ERB volume and/or position during prostate SBRT were necessary to ensure the delivery of the dose distribution as planned.

physics.med-ph

Revealing buried information: Statistical processing techniques for ultracold gas image analysis

The techniques of principal and independent component analysis are applied to images of ultracold atoms. As an illustrative example, we present the use of these model-independent methods to rapidly determine the differential phase of a BEC interferometer from large sets of images of interference patterns. These techniques have been useful in the calibration of the experiment and in the investigation of phase randomization. The details of the algorithms are provided.

physics.atom-ph

High efficiency symmetric beam splitter for cold atoms with a standing wave light pulse sequence

In a recent experiment [1], it was observed that a sequence of two standing wave square pulses can split a BEC at rest into +/- 2 h_bar k diffraction orders with almost 100% efficiency. By truncating the Raman-Nath equations to a 2-state model, we provide an intuitive picture that explains this double square pulse beamsplitter scheme. We further show it is possible to optimize a standingwave multi square pulse sequence to efficiently diffract an atom at rest to symmetric superposition of +/- 2n h_bar k diffraction order with n>1. The approach is considered to be qualitatively different from the traditional light pulse schemes in the Bragg or the Raman-Nath region, and can be extended to more complex atomic optical elements that produce various tailored output momentum states from a cold atom source.

physics.atom-ph

An Atom Michelson Interferometer on a Chip Using a Bose-Einstein Condensate

An atom Michelson interferometer is implemented on an "atom chip." The chip uses lithographically patterned conductors and external magnetic fields to produce and guide a Bose-Einstein condensate. Splitting, reflecting, and recombining of condensate atoms are achieved by a standing-wave light field having a wave vector aligned along the atom waveguide. A differential phase shift between the two arms of the interferometer is introduced by either a magnetic-field gradient or with an initial condensate velocity. Interference contrast is still observable at 20% with atom propagation time of 10 ms.

cond-mat.other