SearcharxivSearch

arXiv subjects

R. Bertoni

Publications and source records attributed to R. Bertoni.

At least 19 recordsLinked to original sources

First operation of the FAMU experiment at the RIKEN-RAL high intensity muon beam facility

The FAMU experiment, supported and funded by the Italian Institute of Nuclear Physics (INFN) and by the Science and Technology Facilities Council (STFC), aims to perform the first measurement of the ground-state hyperfine splitting (1S-hfs) of muonic hydrogen ($\mu H$). This quantity is highly sensitive to the proton's Zemach radius $R_Z$. An experimental determination of $R_Z$ provides significant constraints on the parametrization of the proton form factors as well as on theoretical models describing the proton's electromagnetic structure. Following years of technological and methodological development, the FAMU experiment began operations in 2023 at Port 1 of the RIKEN-RAL muon beam line at the ISIS Neutron and Muon Source facility (Didcot, UK). In this paper, we first describe the unique detection technique employed by FAMU to determine the 1S-hfs of muonic hydrogen, followed by a detailed presentation of the final experimental layout. Finally, we report the first outcome from the 2023 commissioning run and from the initial physics runs performed in 2023 and 2024.

physics.atom-ph

Optimization of LYSO crystals and SiPM parameters for the CMS MIP timing detector

For the High-Luminosity (HL-LHC) phase, the upgrade of the Compact Muon Solenoid (CMS) experiment at CERN will include a novel MIP Timing Detector (MTD). The central part of MTD, the barrel timing layer (BTL), is designed to provide a measurement of the time of arrival of charged particles with a precision of 30 ps at the beginning of HL-LHC, progressively degrading to 60 ps while operating in an extremely harsh radiation environment for over a decade. In this paper we present a comparative analysis of the time resolution of BTL module prototypes made of LYSO:Ce crystal bars read out by silicon photo-multipliers (SiPMs). The timing performance measured in beam test campaigns is presented for prototypes with different construction and operation parameters, such as different SiPM cell sizes (15, 20, 25 and 30 $\rm \mu m$), SiPM manufacturers and crystal bar thicknesses. The evolution of time resolution as a function of the irradiation level has been studied using non-irradiated SiPMs as well as SiPMs exposed up to $2\times 10^{14}~n_{eq}/cm^2$ fluence. The key parameters defining the module time resolution such as SiPM characteristics (gain, photon detection efficiency, radiation induced dark count rate) and crystal properties (light output and dimensions) are discussed. These results have informed the final choice of the MTD barrel sensor configuration and offer a unique starting point for the design of future large-area scintillator-based timing detectors in either low or high radiation environments.

physics.ins-det

The muon beam monitor for the FAMU experiment: design, simulation, test and operation

FAMU is an INFN-led muonic atom physics experiment based at the RIKEN-RAL muon facility at the ISIS Neutron and Muon Source (United Kingdom). The aim of FAMU is to measure the hyperfine splitting in muonic hydrogen to determine the value of the proton Zemach radius with accuracy better than 1%.The experiment has a scintillating-fibre hodoscope for beam monitoring and data normalisation. In order to carry out muon flux estimation, low-rate measurements were performed to extract the single-muon average deposited charge. Then, detector simulation in Geant4 and FLUKA allowed a thorough understanding of the single-muon response function, crucial for determining the muon flux. This work presents the design features of the FAMU beam monitor, along with the simulation and absolute calibration measurements in order to enable flux determination and enable data normalisation.

physics.ins-det

Investigating the Proton Structure: The FAMU experiment

The article gives the motivations for the measurement of the hyperfine splitting (hfs) in the ground state of muonic hydrogen to explore the properties of the proton at low momentum transfer. It summarizes these proposed measurement methods and finally describes the FAMU experiment in more detail.

physics.atom-ph

One inch LaBr3:Ce detectors, with temperature control and improved time resolution for low energy X-rays spectroscopy

Large area LaBr3:Ce detectors with a SiPM array readout have been developed for the FAMU experiment at RAL. The aim was to have a good energy resolution for low energy X-rays detection (around 100 keV) and good timing properties of the signal pulse. Sixteen 1" detectors and twelve 1/2" detectors have been presently installed in the FAMU experiment and are taking data since March 2023, at RIKEN RAL Port 1.

physics.ins-det

Status of the detector setup for the FAMU experiment at RIKEN-RAL for a precision measurement of the Zemach radius of the proton in muonic hydrogen

The FAMU experiment at RIKEN-RAL is a muonic atom experiment with the aim to determine the Zemach radius of the proton by measuring the 1s hyperfine splitting in muonic hydrogen. The activity of the FAMU Collaboration in the years 2015-2023 enabled the final optimisation of the detector-target setup as well as the gas working condition in terms of temperature, pressure and gas mixture composition. The experiment has started its data taking in July 2023. The status of the detector setup for the 2023 experimental runs, for the beam characterisation and muonic X-ray detection in the 100-200 keV energy range, is presented and discussed.

physics.atom-ph

Improving the Time Resolution of Large-Area LaBr3:Ce Detectors with SiPM Array Readout

LaBr3:Ce crystals have good scintillation properties for X-ray spectroscopy. Initially, they were introduced for radiation imaging in medical physics with either a photomultiplier or SiPM readout, and they found extensive applications in homeland security and gamma-ray astronomy. We used 1 inch round LaBr3:Ce crystals to realize compact detectors with the SiPM array readout. The aim was a good energy resolution and a fast time response to detect low-energy X-rays around 100 keV. A natural application was found inside the FAMU experiment, at RIKEN RAL. Its aim is a precise measurement of the proton Zemach radius with impinging muons, to contribute to the solution to the so-called proton radius puzzle. Signals to be detected are characteristic X-rays around 130 KeV. A limit for this type of detector, as compared to the ones with a photomultiplier readout, is its poorer timing characteristics due to the large capacity of the SiPM arrays used. In particular, long signal falltimes are a problem in experiments such as FAMU, where a prompt background component must be separated from a delayed one (after 600 ns) in the signal X-rays to be detected. Dedicated studies were pursued to improve the timing characteristics of the used detectors, starting from hybrid ganging of SiPM cells; then developing a suitable zero pole circuit with a parallel ganging, where an increased overvoltage for the SiPM array was used to compensate for the signal decrease; and finally designing ad hoc electronics to split the 1 inch detector SiPM array into four quadrants, thus reducing the involved capacitances. The aim was to improve the detectors timing characteristics, especially falltime, while keeping a good FWHM energy resolution for low-energy X-ray detection.

physics.ins-det

Transverse Emittance Reduction in Muon Beams by Ionization Cooling

Accelerated muon beams have been considered for next-generation studies of high-energy lepton-antilepton collisions and neutrino oscillations. However, high-brightness muon beams have not yet been produced. The main challenge for muon acceleration and storage stems from the large phase-space volume occupied by the beam, derived from the muon production mechanism through the decay of pions from proton collisions. Ionization cooling is the technique proposed to decrease the muon beam phase-space volume. Here we demonstrate a clear signal of ionization cooling through the observation of transverse emittance reduction in beams that traverse lithium hydride or liquid hydrogen absorbers in the Muon Ionization Cooling Experiment (MICE). The measurement is well reproduced by the simulation of the experiment and the theoretical model. The results shown here represent a substantial advance towards the realization of muon-based facilities that could operate at the energy and intensity frontiers.

physics.acc-ph

Calibration of the ICARUS cryogenic photo-detection system at FNAL

The calibration of the ICARUS photo-detection system is based on a low power laser diode at 405 nm. Laser pulses arrive to one optical switch and then are sent to 36 UHV flanges, by 20 meters long optical patches. Light is then delivered to the ten PMTs connected to a single flange, by 7m long injection optical patches. Extensive tests of the used components and care in the design of the optical system have guaranteed to each PMT a sizeable calibration signal with minimal distortion, with respect to the original one. Gain equalization of PMTs has reached a 1 per cent resolution. In this procedure data from background photons were also used. The distribution of the PMTs signal arrival time has a distribution with a resolution less than 1 ns, thus allowing a good determination of the absolute event timing. The status of the laser calibration system with its possible upgrades will be reported.

physics.ins-det

Large area LaBr3:Ce crystals read by SiPM arrays with improved timing and temperature gain drift control

Compact X-rays detectors made of 1/2" or 1" :LaBr3:Ce crystals of cubic shape with SiPM array readout have been developed for the FAMU experiment at RIKEN-RAL. The aim is a precise measurement of the proton Zemach radius with incoming muons. Additional applications may be found in medical physics, such as PET, homeland security and gamma-ray astronomy. Due to the high photon yield of LaBr3:Ce it was possible to use a simple readout scheme based on CAEN V1730 digitizers. Detectors, using Hamamatsu S13361 or S14161 arrays, have good FWHM energy resolutions up to 3 % (8 %) at the Cs137 Co57) peak, comparing well with the best results obtained with a photomultiplier's readout. Detailed studies were performed to correct online the drift with temperature of SiPM gain and to reduce the risetime/falltime of detectors' signals, that increased going from 1/2" to 1" detectors, due to the larger capacity of the used SiPM arrays.

physics.ins-det

Online control of the gain drift with temperature of SiPM arrays used for the readout of LaB$_3$:Ce crystals

LaB$_3$:Ce crystals have been introduced for radiation imaging in medical physics, with photomultiplier or single SiPM readout. An R-D was pursued with 1/2" and 1" LaBr3:Ce crystals, from different producers, to realize compact large area detectors (up to some cm$^2$ area) with SiPM array readout, aiming at high light yields, good energy resolution, good detector linearity and fast time response for low-energy X-rays. A natural application was found inside the FAMU project at RIKEN-RAL muon facility, that aims at a precise measure of the proton Zemach radius to solve the so-called "proton radius puzzle", triggered by the recent measure of the proton charge radius at PSI. The goal is the detection of characteristic X-rays around 130 keV. Other applications may be foreseen in medical physics, such as PET, and gamma-ray astronomy. A limiting factor is the gain drift of SiPM arrays with temperature, that give a deterioration of the detector's FWHM energy resolution. To solve this problem, a custom NIM module, based on CAEN A7585 digital power supply, was developed. Test results of the correction of gain drift with temperature for SiPM arrays from Advansid, Sensl, Hamamatsu will be presented. At the $^{137}$Cs peak, an energy resolution better than 3% was obtained for a typical LaBr$_3$:Ce crystal, using Hamamatsu S13461 arrays. This compares well with best available results obtained with PMTs.

physics.ins-det

Multiple Coulomb Scattering of muons in Lithium Hydride

Multiple Coulomb Scattering (MCS) is a well known phenomenon occurring when charged particles traverse materials. Measurements of muons traversing low $Z$ materials made in the MuScat experiment showed that theoretical models and simulation codes, such as GEANT4 (v7.0), over-estimated the scattering. The Muon Ionization Cooling Experiment (MICE) measured the cooling of a muon beam traversing a liquid hydrogen or lithium hydride (LiH) energy absorber as part of a programme to develop muon accelerator facilities, such as a Neutrino Factory or a Muon Collider. The energy loss and MCS that occur in the absorber material are competing effects that alter the performance of the cooling channel. Therefore measurements of MCS are required in order to validate the simulations used to predict the cooling performance in future accelerator facilities. We report measurements made in the MICE apparatus of MCS using a LiH absorber and muons within the momentum range 160 to 245 MeV/c. The measured RMS scattering width is about 9% smaller than that predicted by the approximate formula proposed by the Particle Data Group. Data at 172, 200 and 240 MeV/c are compared to the GEANT4 (v9.6) default scattering model. These measurements show agreement with this more recent GEANT4 (v9.6) version over the range of incident muon momenta.

hep-ex

Detection of low-energy X-rays with 1/2 and 1 inch LaBr3:Ce crystals read by SIPM arrays

LaBr3:Ce crystals, with photomultiplier or single SiPM readout (up to 3x3 mm$^2$) have been introduced for radiation imaging in medical physics. An R&D was pursued with 1/2" and 1" LaBr3:Ce crystals, from different producers, to realize compact large area detectors (up to some cm $^2$ area) with SiPM array readout, aiming at high light yields, good energy resolution,good detector linearity and fast time response for low-energy X-rays. The study was triggered by the FAMU experiment at the RIKEN-RAL muon facility, aiming at a precise measurement of the proton Zemach radius to solve the so-called "proton radius puzzle". The goal is the detection of characteristic X-rays around 130 KeV. Other applications may be foreseen for homeland security and $\gamma$-ray astronomy. Results were obtained with a direct readout based on a CAEN V1730 FADC, with no need for an amplification stage. At the Cs$^{137}$ peak, energy resolutions up to $\sim 3 \%$ were obtained, using a readout with Hamamatsu SiPM arrays. These results compare well with best available results obtained with a PMT readout.

physics.ins-det

Effective exploitation of a geyser bubble-chamber equipment as a background-free fast neutron detector

MOSCAB equipment, a geyser-concept bubble-chamber originally thought for the search of dark matter in the form of WIMPs, is employed for the detection of fast neutrons. Once the background-free operating conditions are determined such that the detector is sensitive only to neutrons, which occurs when the neutron energy threshold required for nucleation is higher than approximately 2.5 MeV, the detector response to fast neutrons is investigated using an AmBe neutron source. Sets of detection efficiency functions are then produced via Monte Carlo simulations and post-processing, their validation being performed experimentally and discussed. Finally, the use of the detector to measure the fast neutron activity of very weak n-sources in clean environments, as well as to monitor the cosmic ray variations through the neutron component of the Extensive Air Showers, is considered.

physics.ins-det

Performance of the MICE diagnostic system

Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams of a neutrino factory and for multi-TeV lepton-antilepton collisions at a muon collider. The international Muon Ionization Cooling Experiment (MICE) has demonstrated the principle of ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. This paper documents the performance of the detectors used in MICE to measure the muon-beam parameters, and the physical properties of the liquid hydrogen energy absorber during running.

physics.acc-ph

Measurement of the muon transfer rate from muonic hydrogen to oxygen in the range 70-336 K

The first measurement of the temperature dependence of the muon transfer rate from muonic hydrogen to oxygen was performed by the FAMU collaboration in 2016. The results provide evidence that the transfer rate rises with the temperature in the range 104-300 K. This paper presents the results of the experiment done in 2018 to extend the measurements towards lower (70 K) and higher (336 K) temperatures. The 2018 results confirm the temperature dependence of the muon transfer rate observed in 2016 and sets firm ground for comparison with the theoretical predictions.

physics.atom-ph

Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector

The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about 30 ps at the beginning of operation, and degrading to 50-60 ps at the end of the detector lifetime as a result of radiation damage. In this work, we present the results obtained using a 120 GeV proton beam at the Fermilab Test Beam Facility to measure the time resolution of unirradiated sensors. A proof-of-concept of the sensor layout proposed for the barrel region of the MTD, consisting of elongated crystal bars with dimensions of about 3 x 3 x 57 mm$^3$ and with double-ended SiPM readout, is demonstrated. This design provides a robust time measurement independent of the impact point of the MIP along the crystal bar. We tested LYSO:Ce bars of different thickness (2, 3, 4 mm) with a geometry close to the reference design and coupled to SiPMs manufactured by Hamamatsu and Fondazione Bruno Kessler. The various aspects influencing the timing performance such as the crystal thickness, properties of the SiPMs (e.g. photon detection efficiency), and impact angle of the MIP are studied. A time resolution of about 28 ps is measured for MIPs crossing a 3 mm thick crystal bar, corresponding to an MPV energy deposition of 2.6 MeV, and of 22 ps for the 4.2 MeV MPV energy deposition expected in the BTL, matching the detector performance target for unirradiated devices.

physics.ins-det

The laser diode calibration system of the ICARUS T600 detector at FNAL

The ICARUS T600 LAr TPC is the far detector of the Short Baseline Program at FNAL. As it will have to work at shallow depth in the Booster Neutrino Beam, a large cosmic rays background ($\sim 11$ kHz) will be present. To reduce it, precise timing information is needed from the new light detection system, based on 360 large area photomultipliers. For precise time measurements a calibration system based on a fast laser diode and a system based on one optical switch, several $1 \times 10$ fused fiber splitters, ultra-high vacuum optical feedthroughs and multimode optical patchcords up to 20 m long, to distribute the laser pulses to each single PMT, was designed. The time evolution of the PMTs' gain/timing and possibly their initial calibrations at a time $t_0$ will be done by using this system. The expected time resolution of this calibration system will be around 100 ps. The laboratory tests needed to set up the system are reported.

physics.ins-det