SearcharxivSearch

arXiv subjects

R. Boudot

Publications and source records attributed to R. Boudot.

14 recordsLinked to original sources

Microfabricated multi-axis cell for integrated atomic devices

Microfabricated alkali vapor cells enable the miniaturization of atomic sensors, but require collective wafer-level integration of complex features. In many applications, including magnetometers, gyroscopes, magneto-optical traps, and fluorescence imaging, multiple optical accesses are needed to enhance performance. Yet, achieving this without compromising manufacturability remains challenging. In this work, we present a wafer-level fabrication approach that enables three orthogonal optical pathways in microfabricated alkali vapor cells, using fully scalable and collective processes. Our method relies on the thermal reflow of glass preforms, shaped by laser-assisted etching (LAE) and bonded between silicon frames. The relatively low surface roughness produced by LAE allows effective reflow, which further smooths the surfaces without significantly compromising the optical planarity of the windows. This process results in multi-axis vapor cells featuring embedded, optics-grade lateral windows. We evaluate the device performance through both single-beam and dual-beam atomic magnetometry measurements. Magnetic sensitivities better than 200 fT/sqrt(Hz) are demonstrated along each of the three orthogonal axes, confirming the potential of the approach for tri-axis magnetic field sensing at sub-picotesla resolution. This fabrication strategy opens new perspectives for versatile, high-performance atomic sensors, fully compatible with wafer-level integration and mass production.

physics.atom-ph

Doppler-free spectroscopy of the Cs $6\text{S}_{1/2}-7\text{P}_{3/2}$ atomic transition at 456 nm in a nanometric-thick vapor layer

The features of Doppler-free resonances detected by probing the $^{133}$Cs atom $6S_{1/2}-7P_{3/2}$ transition at 456 nm in a nanometric-thick vapor layer are investigated. The matrix element of this transition is about 11 times smaller than that of the Cs D$_2$ line (852 nm). When the vapor layer thickness is $\ell = \lambda/2 \simeq 230$ nm, we observe Dicke narrowing of the lines, accompanied by a red frequency shift of the atomic transitions, which is attributed to atom-surface interactions. Realizing optical pumping with $\ell\simeq 460$ nm in a single-pass configuration, we observe Doppler-free resonances with a linewidth $<20$ MHz, located at the atomic transitions frequencies with a correspondence of the amplitudes to the transition intensities. These narrow resonances are of interest for high-resolution spectroscopy and instrumentation, and could serve as a frequency reference.

physics.atom-ph

Cs microcell optical reference at 459 nm with short-term frequency stability below 2 $\times$ 10$^{-13}$

We describe the short-term frequency stability characterization of external-cavity diode lasers stabilized onto the 6S$_{1/2}$-7P$_{1/2}$ transition of Cs atom at 459 nm, using a microfabricated vapor cell. The laser beatnote between two nearly-identical systems, each using saturated absorption spectroscopy in a simple retroreflected configuration, exhibits an instability of $2.5\times10^{-13}$ at 1 s, consistent with phase noise analysis, and $3\times 10^{-14}$ at 200 s. The primary contributors to the stability budget at one second are the FM-AM noise conversion and the intermodulation effect, both emerging from laser frequency noise. These results highlight the potential of microcell-based optical references to achieve stability performances comparable to that of an active hydrogen maser in a remarkably simple architecture.

physics.atom-ph

Reduction of helium permeation in microfabricated cells using aluminosilicate glass substrates and Al$_2$O$_3$ coatings

The stability and accuracy of atomic devices can be degraded by the evolution of their cell inner atmosphere. Hence, the undesired entrance or leakage of background or buffer gas, respectively, that can permeate through the cell walls, should be slowed down. In this work, we investigate helium permeation in microfabricated alkali vapor cells filled with He and whose windows are made of borosilicate glass (BSG) or aluminosilicate glass (ASG). The permeation is then derived from routine measurements of the pressure-shifted hyperfine transition frequency of an atomic clock. We first confirm that ASG reduces He permeation rate by more than two orders of magnitude, in comparison with BSG. In addition, we demonstrate that Al$_2$O$_3$ thin-film coatings, known to avoid alkali consumption in vapor cells, can also significantly reduce He permeation. The permeation through BSG is thereby reduced by a factor 110 whereas the one through ASG is decreased by a factor up to 5.8 compared to uncoated substrates. These results may contribute to the development of miniaturized atomic clocks and sensors with improved long-term stability or sensitivity.

physics.atom-ph

Light-shift mitigation in a microcell-based atomic clock with Symmetric Auto-Balanced Ramsey spectroscopy

The mid-term fractional frequency stability of miniaturized atomic clocks can be limited by light-shift effects. In this Letter, we demonstrate the implementation of a symmetric Auto-Balanced Ramsey (SABR) interrogation sequence in a microcell-based atomic clock based on coherent population trapping (CPT). Using this advanced protocol, the sensitivity of the clock frequency to laser power, microwave power and laser frequency variations is reduced, at least by one order of magnitude, in comparison with continuous-wave (CW) or Ramsey interrogation schemes. Light-shift mitigation obtained with the SABR sequence benefits greatly to the clock Allan deviation for integration times between 10$^2$ and 10$^5$ s. These results demonstrate that such interrogation techniques are of interest to enhance timekeeping performances of chip-scale atomic clocks.

physics.atom-ph

A simple imaging solution for chip-scale laser cooling

We demonstrate a simple stacked scheme that enables absorption imaging through a hole in the surface of a grating magneto-optical trap (GMOT) chip, placed immediately below a micro-fabricated vacuum cell. The imaging scheme is capable of overcoming the reduced optical access and surface scatter that is associated with this chip-scale platform, while further permitting both trapping and imaging of the atoms from a single incident laser beam. The through-hole imaging is used to characterise the impact of the reduced optical overlap volume of the GMOT in the chip-scale cell, with an outlook to an optimised atom number in low volume systems.

physics.atom-ph

Laser cooling in a chip-scale platform

Chip-scale atomic devices built around micro-fabricated alkali vapor cells are at the forefront of compact metrology and atomic sensors. We demonstrate a micro-fabricated vapor cell that is actively-pumped to ultra-high-vacuum (UHV) to achieve laser cooling. A grating magneto optical trap (GMOT) is incorporated with the 4 mm-thick Si/glass vacuum cell to demonstrate the feasibility of a fully-miniaturized laser cooling platform. A two-step optical excitation process in rubidium is used to overcome surface-scatter limitations to the GMOT imaging. The unambiguous miniaturization and form-customizability made available with micro-fabricated UHV cells provide a promising platform for future compact cold-atom sensors.

physics.atom-ph

Advanced light-shift compensation protocol in a continuous-wave microcell atomic clock

Light-shifts are known to be an important limitation to the mid- and long-term fractional frequency stability of different types of atomic clocks. In this article, we demonstrate the experimental implementation of an advanced anti-light shift interrogation protocol onto a continuous-wave (CW) microcell atomic clock based on coherent population trapping (CPT). The method, inspired by the Auto-Balanced Ramsey (ABR) spectroscopy technique demonstrated in pulsed atomic clocks, consists in the extraction of atomic-based information from two successive light-shifted clock frequencies obtained at two different laser power values. Two error signals, computed from the linear combination of signals acquired along a symmetric sequence, are managed in a dual-loop configuration to generate a clock frequency free from light-shift. Using this method, the sensitivity of the clock frequency to both laser power and microwave power variations can be reduced by more than an order of magnitude compared to normal operation. In the present experiment, the consideration of the non-linear light-shift dependence allowed to enhance light-shift mitigation. The implemented technique allows a clear improvement of the clock Allan deviation for time scales higher than 1000 s. This method could be applied in various kinds of atomic clocks such as CPT-based atomic clocks, double-resonance Rb clocks, or cell-stabilized lasers.

physics.atom-ph

Universal methods for suppressing the light shift in atomic clocks using power modulation

We show that the light shift in atomic clocks can be suppressed using time variation of the interrogation field intensity. By measuring the clock output at two intensity levels, error signals can be generated that simultaneously stabilize a local oscillator to an atomic transition and correct for the shift of this transition caused by the interrogating optical field. These methods are suitable for optical clocks using one- and two-photon transitions, as well as for microwave clocks based on coherent population trapping or direct interrogation. The proposed methods can be widely used both for high-precision scientific instruments and for a wide range of commercial clocks, including chip-scale atomic clocks.

physics.atom-ph

Reduction of light shifts in Ramsey spectroscopy with a combined error signal

Light-induced frequency shifts can be a key limiting contribution to the mid and long-term frequency instability in atomic clocks. In this letter, we demonstrate the experimental implementation of the combined error signal interrogation protocol to a cold-atom clock based on coherent population trapping (CPT) and Ramsey spectroscopy. The method uses a single error signal that results from the normalized combination of two error signals extracted from two Ramsey sequences of different dark periods. The single combined error signal is used to stabilize the atomic clock frequency. Compared to the standard Ramsey-CPT interrogation, this method reduces the clock frequency sensitivity to light-shift variations by more than one order of magnitude. This method can be applied in various kinds of Ramsey-based atomic clocks, sensors and instruments.

physics.atom-ph

Ramsey Spectroscopy with Displaced Frequency Jumps

Sophisticated Ramsey-based interrogation protocols using composite laser pulse sequences have been recently proposed to provide next-generation high-precision atomic clocks with a near perfect elimination of frequency shifts induced during the atom-probing field interaction. We propose here a simple alternative approach to the auto-balanced Ramsey (ABR) interrogation protocol and demonstrate its application to a cold-atom microwave clock based on coherent population trapping. The main originality of the method, based on two consecutive Ramsey sequences with different dark periods, is to sample the central Ramsey fringes with frequency-jumps finely-adjusted by an additional frequency-displacement concomitant parameter, scaling as the inverse of the dark-period. The advantage of this displaced frequency-jumps Ramsey (DFJR) method is that the local oscillator frequency is used as a single physical variable to control both servo loops of the sequence, simplifying its implementation and avoiding noise associated with controlling the LO phase. Compared to the usual Ramsey-CPT technique, the DFJR scheme reduces the sensitivity of the clock frequency to variations of the CPT sideband ratio and to the one-photon laser detuning by more than an order of magnitude. This simple method could be applied in a wide variety of Ramsey-spectroscopy based applications including frequency metrology with CPT-based and optical atomic clocks, mass spectrometry, and precision spectroscopy.

physics.atom-ph

Advanced noise reduction techniques for ultra-low phase noise optical-to-microwave division with femtosecond fiber combs

We report what we believe to be the lowest phase noise optical-to-microwave frequency division using fiber-based femtosecond optical frequency combs: a residual phase noise of -120dBc/Hz at 1 Hz offset from a 11.55GHz carrier frequency. We furthermore report a detailed investigation into the fundamental noise sources which afflicts the division process itself. Two frequency combs with quasi-identical configurations are referenced to a common ultrastable cavity laser source. To identify each of the limiting effects we implement an ultra-low noise carrier-suppression measurement system, which circumvents the detection and amplification noise of more conventional techniques. This technique now allows the suppression of these unwanted sources of noise to very low levels. In the Fourier frequency range of ~200 Hz to 100 kHz, a fed-forward technique based on a voltage-controlled phase shifter delivers a further noise reduction of 10 dB. For lower Fourier frequencies, optical power stabilization is implemented in order to reduce the relative intensity noise which causes unwanted phase noise through power to phase conversion in the detector. We implement and compare two possible control schemes based on an acousto-optical modulator and comb pump current. We also present wideband measurements on the relative intensity noise of the fiber comb.

physics.optics

Sub-100 attoseconds optics-to-microwave synchronization

We use two fiber-based femtosecond frequency combs and a low-noise carrier suppression phase detection system to characterize the optical to microwave synchronization achievable with such frequency divider systems. By applying specific noise reduction strategies, a residual phase noise as low as -120 dBc/Hz at 1 Hz offset frequency from a 11.55 GHz carrier is measured. The fractional frequency instability from a single optical-to-frequency divider is 1.1E-16 at 1 s averaging down to below 2E-19 after only 1000 s. The corresponding rms time deviation is lower than 100 attoseconds up to 1000 s averaging duration.

physics.optics

Ultra-Low Noise Microwave Extraction from Fiber-Based Optical Frequency Comb

In this letter, we report on all-optical fiber approach to the generation of ultra-low noise microwave signals. We make use of two erbium fiber mode-locked lasers phase locked to a common ultra-stable laser source to generate an 11.55 GHz signal with an unprecedented relative phase noise of -111 dBc/Hz at 1 Hz from the carrier.The residual frequency instability of the microwave signals derived from the two optical frequency combs is below 2.3 10^(-16) at 1s and about 4 10^(-19) at 6.5 10^(4)s (in 5 Hz bandwidth, three days continuous operation).

physics.optics