Searcharxiv⌕ Search

arXiv subjects

R. Breier

Publications and source records attributed to R. Breier.

32 records · Page 2Linked to original sources

Observation of a low energy nuclear recoil peak in the neutron calibration data of the CRESST-III Experiment

New-generation direct searches for low mass dark matter feature detection thresholds at energies well below 100 eV, much lower than the energies of commonly used X-ray calibration sources. This requires new calibration sources with sub-keV energies. When searching for nuclear recoil signals, the calibration source should ideally cause mono-energetic nuclear recoils in the relevant energy range. Recently, a new calibration method based on the radiative neutron capture on $^{182}$W with subsequent de-excitation via single $γ$-emission leading to a nuclear recoil peak at 112 eV was proposed. The CRESST-III dark matter search operated several CaWO$_{4}$-based detector modules with detection thresholds below 100 eV in the past years. We report the observation of a peak around the expected energy of 112 eV in the data of three different detector modules recorded while irradiated with neutrons from different AmBe calibration sources. We compare the properties of the observed peaks with Geant-4 simulations and assess the prospects of using this for the energy calibration of CRESST-III detectors.

physics.ins-det↗

Results on sub-GeV Dark Matter from a 10 eV Threshold CRESST-III Silicon Detector

We present limits on the spin-independent interaction cross section of dark matter particles with silicon nuclei, derived from data taken with a cryogenic calorimeter with 0.35 g target mass operated in the CRESST-III experiment. A baseline nuclear recoil energy resolution of $(1.36\pm 0.05)$ eV$_{\text{nr}}$, currently the lowest reported for macroscopic particle detectors, and a corresponding energy threshold of $(10.0\pm 0.2)$ eV$_{\text{nr}}$ have been achieved, improving the sensitivity to light dark matter particles with masses below 160 MeV/c$^2$ by a factor of up to 20 compared to previous results. We characterize the observed low energy excess, and we exclude noise triggers and radioactive contaminations on the crystal surfaces as dominant contributions.

astro-ph.CO↗

Secular Equilibrium Assessment in a $\mathrm{CaWO}_4$ Target Crystal from the Dark Matter Experiment CRESST using Bayesian Likelihood Normalisation

CRESST is a leading direct detection sub-$\mathrm{GeVc}^{-2}$ dark matter experiment. During its second phase, cryogenic bolometers were used to detect nuclear recoils off the $\mathrm{CaWO}_4$ target crystal nuclei. The previously established electromagnetic background model relies on secular equilibrium (SE) assumptions. In this work, a validation of SE is attempted by comparing two likelihood-based normalisation results using a recently developed spectral template normalisation method based on Bayesian likelihood. We find deviations from SE; further investigations are necessary to determine their origin.

physics.ins-det↗

Towards an automated data cleaning with deep learning in CRESST

The CRESST experiment employs cryogenic calorimeters for the sensitive measurement of nuclear recoils induced by dark matter particles. The recorded signals need to undergo a careful cleaning process to avoid wrongly reconstructed recoil energies caused by pile-up and read-out artefacts. We frame this process as a time series classification task and propose to automate it with neural networks. With a data set of over one million labeled records from 68 detectors, recorded between 2013 and 2019 by CRESST, we test the capability of four commonly used neural network architectures to learn the data cleaning task. Our best performing model achieves a balanced accuracy of 0.932 on our test set. We show on an exemplary detector that about half of the wrongly predicted events are in fact wrongly labeled events, and a large share of the remaining ones have a context-dependent ground truth. We furthermore evaluate the recall and selectivity of our classifiers with simulated data. The results confirm that the trained classifiers are well suited for the data cleaning task.

physics.ins-det↗

Latest observations on the low energy excess in CRESST-III

The CRESST experiment observes an unexplained excess of events at low energies. In the current CRESST-III data-taking campaign we are operating detector modules with different designs to narrow down the possible explanations. In this work, we show first observations of the ongoing measurement, focusing on the comparison of time, energy and temperature dependence of the excess in several detectors. These exclude dark matter, radioactive backgrounds and intrinsic sources related to the crystal bulk as a major contribution.

astro-ph.CO↗

Testing spin-dependent dark matter interactions with lithium aluminate targets in CRESST-III

In the past decades, numerous experiments have emerged to unveil the nature of dark matter, one of the most discussed open questions in modern particle physics. Among them, the CRESST experiment, located at the Laboratori Nazionali del Gran Sasso, operates scintillating crystals as cryogenic phonon detectors. In this work, we present first results from the operation of two detector modules which both have 10.46 g LiAlO$_2$ targets in CRESST-III. The lithium contents in the crystal are $^6$Li, with an odd number of protons and neutrons, and $^7$Li, with an odd number of protons. By considering both isotopes of lithium and $^{27}$Al, we set the currently strongest cross section upper limits on spin-dependent interaction of dark matter with protons and neutrons for the mass region between 0.25 and 1.5 GeV/c$^2$.

astro-ph.CO↗

EXCESS workshop: Descriptions of rising low-energy spectra

Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.

astro-ph.IM↗

Probing spin-dependent dark matter interactions with $^6$Li

CRESST is one of the most prominent direct detection experiments for dark matter particles with sub-GeV/c$^2$ mass. One of the advantages of the CRESST experiment is the possibility to include a large variety of nuclides in the target material used to probe dark matter interactions. In this work, we discuss in particular the interactions of dark matter particles with protons and neutrons of $^{6}$Li. This is now possible thanks to new calculations on nuclear matrix elements of this specific isotope of Li. To show the potential of using this particular nuclide for probing dark matter interactions, we used the data collected previously by a CRESST prototype based on LiAlO$_2$ and operated in an above ground test-facility at Max-Planck-Institut für Physik in Munich, Germany. In particular, the inclusion of $^{6}$Li in the limit calculation drastically improves the result obtained for spin-dependent interactions with neutrons in the whole mass range. The improvement is significant, greater than two order of magnitude for dark matter masses below 1 GeV/c$^2$, compared to the limit previously published with the same data.

physics.ins-det↗

Measurement of the distribution of $^{207}$Bi depositions on calibration sources for SuperNEMO

The SuperNEMO experiment will search for neutrinoless double-beta decay ($0νββ$), and study the Standard-Model double-beta decay process ($2νββ$). The SuperNEMO technology can measure the energy of each of the electrons produced in a double-beta ($ββ$) decay, and can reconstruct the topology of their individual tracks. The study of the double-beta decay spectrum requires very accurate energy calibration to be carried out periodically. The SuperNEMO Demonstrator Module will be calibrated using 42 calibration sources, each consisting of a droplet of $^{207}$Bi within a frame assembly. The quality of these sources, which depends upon the entire $^{207}$Bi droplet being contained within the frame, is key for correctly calibrating SuperNEMO's energy response. In this paper, we present a novel method for precisely measuring the exact geometry of the deposition of $^{207}$Bi droplets within the frames, using Timepix pixel detectors. We studied 49 different sources and selected 42 high-quality sources with the most central source positioning.

physics.ins-det↗

Cryogenic characterization of a LiAlO$_{2}$ crystal and new results on spin-dependent dark matter interactions with ordinary matter

In this work, a first cryogenic characterization of a scintillating LiAlO$_{2}$ single crystal is presented. The results achieved show that this material holds great potential as a target for direct dark matter search experiments. Three different detector modules obtained from one crystal grown at the Leibniz-Institut für Kristallzüchtung (IKZ) have been tested to study different properties at cryogenic temperatures. Firstly, two 2.8 g twin crystals were used to build different detector modules which were operated in an above-ground laboratory at the Max Planck Institute for Physics (MPP) in Munich, Germany. The first detector module was used to study the scintillation properties of LiAlO$_{2}$ at cryogenic temperatures. The second achieved an energy threshold of (213.02$\pm$1.48) eV which allows setting a competitive limit on the spin-dependent dark matter particle-proton scattering cross section for dark matter particle masses between 350 MeV/c$^{2}$ and 1.50 GeV/c$^{2}$. Secondly, a detector module with a 373 g LiAlO$_{2}$ crystal as the main absorber was tested in an underground facility at the Laboratori Nazionali del Gran Sasso (LNGS): from this measurement it was possible to determine the radiopurity of the crystal and study the feasibility of using this material as a neutron flux monitor for low-background experiments.

physics.ins-det↗

Search for Periodic Modulations of the Rate of Double-Beta Decay of $^{100}$Mo in the NEMO-3 Detector

Double-beta decays of $^{100}$Mo from the 6.0195-year exposure of a 6.914 kg high-purity sample were recorded by the NEMO-3 experiment that searched for neutrinoless double-beta decays. These ultra-rare transitions to $^{100}$Ru have a half-life of approximately $7\times10^{18}$ years, and have been used to conduct the first ever search for periodic variations of this decay mode. The Lomb-Scargle periodogram technique, and its error-weighted extension, were employed to look for periodic modulations of the half-life. Monte Carlo modeling was used to study the modulation sensitivity of the data over a broad range of amplitudes and frequencies. Data show no evidence of modulations with amplitude greater than 2.5% in the frequency range of $0.33225\,{\rm y^{-1}}$ to $365.25\,{\rm y^{-1}}$.

nucl-ex↗

Search for the double-beta decay of 82Se to the excited states of 82Kr with NEMO-3

The double-beta decay of 82Se to the 0+1 excited state of 82Kr has been studied with the NEMO-3 detector using 0.93 kg of enriched 82Se measured for 4.75 y, corresponding to an exposure of 4.42 kg y. A dedicated analysis to reconstruct the gamma-rays has been performed to search for events in the 2e2g channel. No evidence of a 2nbb decay to the 0+1 state has been observed and a limit of T2n 1/2(82Se; 0+gs -> 0+1) > 1.3 1021 y at 90% CL has been set. Concerning the 0nbb decay to the 0+1 state, a limit for this decay has been obtained with T0n 1/2(82Se; 0+g s -> 0+1) > 2.3 1022 y at 90% CL, independently from the 2nbb decay process. These results are obtained for the first time with a tracko-calo detector, reconstructing every particle in the final state.

physics.ins-det↗

Geant4-based electromagnetic background model for the CRESST dark matter experiment

The CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) dark matter search experiment aims for the detection of dark matter particles via elastic scattering off nuclei in $\mathrm{CaWO_4}$ crystals. To understand the CRESST electromagnetic background due to the bulk contamination in the employed materials, a model based on Monte Carlo simulations was developed using the Geant4 simulation toolkit. The results of the simulation are applied to the TUM40 detector module of CRESST-II phase 2. We are able to explain up to $(68 \pm 16)\,\mathrm{\%}$ of the electromagnetic background in the energy range between $1\,\mathrm{keV}$ and $40\,\mathrm{keV}$.

astro-ph.IM↗

The Large Enriched Germanium Experiment for Neutrinoless Double Beta Decay (LEGEND)

The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely low backgrounds, at the level of $\sim$0.1 count /(FWHM$\cdot$t$\cdot$yr) in the region of the signal. The current generation $^{76}$Ge experiments GERDA and the MAJORANA DEMONSTRATOR utilizing high purity Germanium detectors with an intrinsic energy resolution of 0.12%, have achieved the lowest backgrounds by over an order of magnitude in the 0$νββ$ signal region of all 0$νββ$ experiments. Building on this success, the LEGEND collaboration has been formed to pursue a tonne-scale $^{76}$Ge experiment. The collaboration aims to develop a phased 0$νββ$ experimental program with discovery potential at a half-life approaching or at $10^{28}$ years, using existing resources as appropriate to expedite physics results.

physics.ins-det↗