Searcharxiv⌕ Search

arXiv subjects

R. Cardarelli

Publications and source records attributed to R. Cardarelli.

At least 37 records · Page 2Linked to original sources

A 50 ps resolution monolithic active pixel sensor without internal gain in SiGe BiCMOS technology

A monolithic pixelated silicon detector designed for high time resolution has been produced in the SG13G2 130 nm SiGe BiCMOS technology of IHP Mikroelektronik. This proof-of-concept chip contains hexagonal pixels of 65 μm and 130 μm side. The SiGe front-end electronics implemented provides an equivalent noise charge of 90 and 160 electrons for a pixel capacitance of 70 and 220 fF, respectively, and a total time walk of less than 1 ns. Lab measurements with a 90Sr source show a time resolution of the order of 50 ps. This result is competitive with silicon technologies that integrate an avalanche gain mechanism.

physics.ins-det↗

RPC performance vs FE electoronics and detector parameters

The first Resistive Plate Chambers detectors were developed for cosmic ray experiments, where low rate capability, good time resolution and low cost per unit of area were needed. These same features, except for the low rate capability, were required in the muon spectrometers of the collider experiments like LHC. For this purpose newRPCdetectors with increased rate capability were developed. The rate capability improvement has been achieved thanks to the transition from streamer to saturated avalanche regime, in which the average charge produced in the gas dicharge is smaller. The price to pay for this working mode switch is the transfer of the amplification from the detector to the FE electorinics. The High luminosity LHC and the future colliders will require even greater rate capability in the muon spectrometer compared to the current one. For this reason, further improving of the rate capability is required. The transition from the saturated avalanche to a low saturated avalanche regime moves in this direction and needs a new front end electronics with better signal to noise ratio, because the average induced charge on the electrode is even smaller. The front end electronics design is crucial for the RPC performances. In this paper we discuss the performances of the RPC detector changing the front end design and the detector parameters.

physics.ins-det↗

Development of gaseous particle detectors based on semiconductive plate electrodes

A new particle detector with sub-nanosecond time resolution capable of working in high-rate environment (rate capability of the order of $MHz/ cm^2$) is under developmnet. Semiconductive electrodes with resistivity $ρ$ up to $10^8 Ω\cdot cm$ have been used to improve the RPC [1] [2] rate capability. In this paper efficiency and time resolution of three different detector structures are presented.

physics.ins-det↗

Optimization of RPCs read-out panel with electromagnetic simulation

With the upgrade of the RPCs [1]-[2] and the increase of its performances, the study and the optimization of the read-out panel is necessary in order to maintain the signal integrity and to reduce the intrinsic crosstalk. Through Electromagnetic Simulation, performed with CST Studio Suite, new panels design are tested and their crosstalk property are studied. The behavior of different type of panel is shown, in particular a panel with the decoupling strip connected through their characteristic impedance to the ground plane is simulated.

physics.ins-det↗

Test beam measurement of the first prototype of the fast silicon pixel monolithic detector for the TT-PET project

The TT-PET collaboration is developing a PET scanner for small animals with 30 ps time-of-flight resolution and sub-millimetre 3D detection granularity. The sensitive element of the scanner is a monolithic silicon pixel detector based on state-of-the-art SiGe BiCMOS technology. The first ASIC prototype for the TT-PET was produced and tested in the laboratory and with minimum ionizing particles. The electronics exhibit an equivalent noise charge below 600 e- RMS and a pulse rise time of less than 2 ns, in accordance with the simulations. The pixels with a capacitance of 0.8 pF were measured to have a detection efficiency greater than 99% and, although in the absence of the post-processing, a time resolution of approximately 200 ps.

physics.ins-det↗

Improving the RPC rate capability

This paper has the purpose to study the rate capability of the Resistive Plate Chamber, RPC, starting from the basic physics of this detector. The effect of different working parameters determining the rate capability is analysed in detail, in order to optimize a new family of RPCs for applications to heavy irradiation environments and in particular to the LHC phase 2. A special emphasis is given to the improvement achievable by minimizing the avalanche charge delivered in the gas. The paper shows experimental results of Cosmic Ray tests, performed to study the avalanche features for different gas gap sizes, with particular attention to the overall delivered charge. For this purpose, the paper studies, in parallel to the prompt electronic signal, also the ionic signal which gives the main contribution to the delivered charge. Whenever possible the test results are interpreted on the base of the RPC detector physics and are intended to extend and reinforce our physical understanding of this detector.

physics.ins-det↗

Response of diamond detector sandwich to 14 MeV neutrons

In this paper we present the measurement of the response of 50 $μ$m thin diamond detectors to 14 MeV neutrons. Such neutrons are produced in fusion reactors and are of particular interest for ITER neutron diagnostics. Among semiconductor detectors diamond has properties most appropriate for harsh radiation and temperature conditions of a fusion reactor. However, 300-500 $μ$m thick diamond detectors suffer significant radiation damage already at neutron fluences of the order of $10^{14}$ n/cm$^2$. It is expected that a 50 $μ$m thick diamond will withstand a fluence of $>10^{16}$ n/cm$^2$. We tested two 50 $μ$m thick single crystal CVD diamonds, stacked to form a "sandwich" detector for coincidence measurements. The detector measured the conversion of 14 MeV neutrons, impinging on one diamond, into $α$ particles which were detected in the second diamond in coincidence with nuclear recoil. For $^{12}C(n,α)^{9}Be$ reaction the total energy deposited in the detector gives access to the initial neutron energy value. The measured 14 MeV neutron detection sensitivity through this reaction by a detector of effective area 3$\times$3 mm$^2$ was $5\times 10^{-7}$ counts cm$^2$/n. This value is in good agreement with Geant4 simulations. The intrinsic energy resolution of the detector was found to be 240 keV FWHM which adds only 10 % to ITER's 14 MeV neutron energy spread.

physics.ins-det↗

Study of the diffuse gamma-ray emission from the Galactic plane with ARGO-YBJ

The events recorded by ARGO-YBJ in more than five years of data collection have been analyzed to determine the diffuse gamma-ray emission in the Galactic plane at Galactic longitudes 25° < l < 100° and Galactic latitudes . The energy range covered by this analysis, from ~350 GeV to ~2 TeV, allows the connection of the region explored by Fermi with the multi-TeV measurements carried out by Milagro. Our analysis has been focused on two selected regions of the Galactic plane, i.e., 40° < l < 100° and 65° < l < 85° (the Cygnus region), where Milagro observed an excess with respect to the predictions of current models. Great care has been taken in order to mask the most intense gamma-ray sources, including the TeV counterpart of the Cygnus cocoon recently identified by ARGO-YBJ, and to remove residual contributions. The ARGO-YBJ results do not show any excess at sub-TeV energies corresponding to the excess found by Milagro, and are consistent with the predictions of the Fermi model for the diffuse Galactic emission. From the measured energy distribution we derive spectral indices and the differential flux at 1 TeV of the diffuse gamma-ray emission in the sky regions investigated.

astro-ph.IM↗

Neutron spectrometer for fast nuclear reactors

In this paper we describe the development and first tests of a neutron spectrometer designed for high flux environments, such as the ones found in fast nuclear reactors. The spectrometer is based on the conversion of neutrons impinging on $^6$Li into $α$ and $t$ whose total energy comprises the initial neutron energy and the reaction $Q$-value. The $^6$LiF layer is sandwiched between two CVD diamond detectors, which measure the two reaction products in coincidence. The spectrometer was calibrated at two neutron energies in well known thermal and 3 MeV neutron fluxes. The measured neutron detection efficiency varies from 4.2$\times 10^{-4}$ to 3.5$\times 10^{-8}$ for thermal and 3 MeV neutrons, respectively. These values are in agreement with Geant4 simulations and close to simple estimates based on the knowledge of the $^6$Li(n,$α$)$t$ cross section. The energy resolution of the spectrometer was found to be better than 100 keV when using 5 m cables between the detector and the preamplifiers.

physics.ins-det↗

Test of a prototype neutron spectrometer based on diamond detectors in a fast reactor

A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a $^6$Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energy resolution. A fast coincidence between two crystals is used to reject background. The detector was read out using two different electronic chains connected to it by a few meters of cable. The first chain was based on conventional charge-sensitive amplifiers, the other used a custom fast charge amplifier developed for this purpose. The prototype has been tested at various neutron sources and showed its practicability. In particular, the detector was calibrated in a TRIGA thermal reactor (LENA laboratory, University of Pavia) with neutron fluxes of $10^8$ n/cm$^2$s and at the 3 MeV D-D monochromatic neutron source named FNG (ENEA, Rome) with neutron fluxes of $10^6$ n/cm$^2$s. The neutron spectrum measurement was performed at the TAPIRO fast research reactor (ENEA, Casaccia) with fluxes of 10$^9$ n/cm$^2$s. The obtained spectra were compared to Monte Carlo simulations, modeling detector response with MCNP and Geant4.

physics.ins-det↗

Search for GeV Gamma Ray Bursts with the ARGO-YBJ Detector: Summary of Eight Years of Observations

The search for Gamma Ray Burst (GRB) emission in the energy range 1-100 GeV in coincidence with the satellite detection has been carried out using the Astrophysical Radiation with Ground-based Observatory at YangBaJing (ARGO-YBJ) experiment. The high altitude location (4300 m a.s.l.), the large active surface ($\sim$ 6700 m$^2$ of Resistive Plate Chambers), the wide field of view ($\sim 2~$sr, limited only by the atmospheric absorption) and the high duty cycle ($>$ 86 %) make the ARGO-YBJ experiment particularly suitable to detect short and unexpected events like GRBs. With the scaler mode technique, i.e., counting all the particles hitting the detector with no measurement of the primary energy and arrival direction, the minimum threshold of $\sim$ 1 GeV can be reached, overlapping the direct measurements carried out by satellites. During the experiment lifetime, from December 17, 2004 to February 7, 2013, a total of 206 GRBs occurring within the ARGO-YBJ field of view (zenith angle $θ$ $\le$ 45$^{\circ}$) have been analyzed. This is the largest sample of GRBs investigated with a ground-based detector. Two lightcurve models have been assumed and since in both cases no significant excess has been found, the corresponding fluence upper limits in the 1-100 GeV energy region have been derived, with values as low as 10$^{-5}~$erg cm$^{-2}$. The analysis of a subset of 24 GRBs with known redshift has been used to constrain the fluence extrapolation to the GeV region together with possible cutoffs under different assumptions on the spectrum.

astro-ph.HE↗

The Knee of the Cosmic Hydrogen and Helium Spectrum below 1 PeV Measured by ARGO-YBJ and a Cherenkov Telescope of LHAASO

The measurement of cosmic ray energy spectra, in particular for individual species, is an essential approach in finding their origin. Locating the "knees" of the spectra is an important part of the approach and has yet to be achieved. Here we report a measurement of the mixed Hydrogen and Helium spectrum using the combination of the ARGO-YBJ experiment and of a prototype Cherenkov telescope for the LHAASO experiment. A knee feature at 640+/-87 TeV, with a clear steepening of the spectrum, is observed. This gives fundamental inputs to galactic cosmic ray acceleration models.

astro-ph.HE↗

Identification of the TeV Gamma-ray Source ARGO J2031+4157 with the Cygnus Cocoon

The extended TeV gamma-ray source ARGO J2031+4157 (or MGRO J2031+41) is positionally consistent with the Cygnus Cocoon discovered by $Fermi$-LAT at GeV energies in the Cygnus superbubble. Reanalyzing the ARGO-YBJ data collected from November 2007 to January 2013, the angular extension and energy spectrum of ARGO J2031+4157 are evaluated. After subtracting the contribution of the overlapping TeV sources, the ARGO-YBJ excess map is fitted with a two-dimensional Gaussian function in a square region of $10^{\circ}\times 10^{\circ}$, finding a source extension $σ_{ext}$= 1$^{\circ}$.8$\pm$0$^{\circ}$.5. The observed differential energy spectrum is $dN/dE =(2.5\pm0.4) \times 10^{-11}(E/1 TeV)^{-2.6\pm0.3}$ photons cm$^{-2}$ s$^{-1}$ TeV$^{-1}$, in the energy range 0.2-10 TeV. The angular extension is consistent with that of the Cygnus Cocoon as measured by $Fermi$-LAT, and the spectrum also shows a good connection with the one measured in the 1-100 GeV energy range. These features suggest to identify ARGO J2031+4157 as the counterpart of the Cygnus Cocoon at TeV energies. The Cygnus Cocoon, located in the star-forming region of Cygnus X, is interpreted as a cocoon of freshly accelerated cosmic rays related to the Cygnus superbubble. The spectral similarity with Supernova Remnants indicates that the particle acceleration inside a superbubble is similar to that in a SNR. The spectral measurements from 1 GeV to 10 TeV allows for the first time to determine the possible spectrum slope of the underlying particle distribution. A hadronic model is adopted to explain the spectral energy distribution.

astro-ph.HE↗

Energy Spectrum of Cosmic Protons and Helium Nuclei by a Hybrid Measurement at 4300 m a.s.l

The energy spectrum of cosmic Hydrogen and Helium nuclei has been measured, below the so-called "knee", by using a hybrid experiment with a wide field-of-view Cherenkov telescope and the Resistive Plate Chamber (RPC) array of the ARGO-YBJ experiment at 4300 m above sea level. The Hydrogen and Helium nuclei have been well separated from other cosmic ray components by using a multi-parameter technique. A highly uniform energy resolution of about 25% is achieved throughout the whole energy range (100 TeV - 700 TeV). The observed energy spectrum is compatible with a single power law with index gamma=-2.63+/-0.06.

astro-ph.HE↗

TeV gamma-ray survey of the Northern sky using the ARGO-YBJ detector

The ARGO-YBJ detector is an extensive air shower array that has been used to monitor the northern $γ$-ray sky at energies above 0.3 TeV from 2007 November to 2013 January. In this paper, we present the results of a sky survey in the declination band from $-10^{\circ}$ to $70^{\circ}$, using data recorded over the past five years. With an integrated sensitivity ranging from 0.24 to $\sim$1 Crab units depending on the declination, six sources have been detected with a statistical significance greater than 5 standard deviations. Several excesses are also reported as potential $γ$-ray emitters. The features of each source are presented and discussed. Additionally, $95\%$ confidence level upper limits of the flux from the investigated sky region are shown. Specific upper limits for 663 GeV $γ$-ray AGNs inside the ARGO-YBJ field of view are reported. The effect of the absorption of $γ$-rays due to the interaction with extragalactic background light is estimated.

astro-ph.HE↗

Observation of TeV gamma-rays from the unidentified source HESS J1841-055 with the ARGO-YBJ experiment

We report the observation of a very high energy γ-ray source, whose position is coincident with HESS J1841-055. This source has been observed for 4.5 years by the ARGO-YBJ experiment from November 2007 to July 2012. Its emission is detected with a statistical significance of 5.3 standard deviations. Parameterizing the source shape with a two-dimensional Gaussian function we estimate an extension σ=(0.40(+0.32,-0.22}) degree, consistent with the HESS measurement. The observed energy spectrum is dN/dE =(9.0-+1.6) x 10^{-13}(E/5 TeV)^{-2.32-+0.23} photons cm^{-2} s^{-1} TeV^{-1}, in the energy range 0.9-50 TeV. The integral γ-ray flux above 1 TeV is 1.3-+0.4 Crab units, which is 3.2-+1.0 times the flux derived by HESS. The differences in the flux determination between HESS and ARGO-YBJ, and possible counterparts at other wavelengths are discussed.

astro-ph.HE↗

Studies on fast triggering and high precision tracking with Resistive Plate Chambers

We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with readout strips with 1.27 mm pitch. This is the first beam test of RPCs with fine-pitch readout strips that explores simultaneously precision tracking and triggering capabilities. RPC signals were acquired with precision timing and charge integrating readout electronics at both ends of the strips. The time resolution was measured to be better than 600 ps and the average spatial resolution was found to be 220 um using charge information and 287 um using timing information. The dual-ended readout allows the determination of the average and the difference of the signal arrival times. The average time was found to be independent of the incident particle position along the strip and is useful for triggering purposes. The time difference yielded a determination of the hit position with a precision of 7.5 mm along the strip. These results demonstrate the feasibility using RPCs for fast and high-resolution triggering and tracking.

physics.ins-det↗

Long-term Monitoring on Mrk 501 for Its VHE gamma Emission and a Flare in October 2011

As one of the brightest active blazars in both X-ray and very high energy $γ$-ray bands, Mrk 501 is very useful for physics associated with jets from AGNs. The ARGO-YBJ experiment is monitoring it for $γ$-rays above 0.3 TeV since November 2007. Starting from October 2011 the largest flare since 2005 is observed, which lasts to about April 2012. In this paper, a detailed analysis is reported. During the brightest $γ$-rays flaring episodes from October 17 to November 22, 2011, an excess of the event rate over 6 $σ$ is detected by ARGO-YBJ in the direction of Mrk 501, corresponding to an increase of the $γ$-ray flux above 1 TeV by a factor of 6.6$\pm$2.2 from its steady emission. In particular, the $γ$-ray flux above 8 TeV is detected with a significance better than 4 $σ$. Based on time-dependent synchrotron self-Compton (SSC) processes, the broad-band energy spectrum is interpreted as the emission from an electron energy distribution parameterized with a single power-law function with an exponential cutoff at its high energy end. The average spectral energy distribution for the steady emission is well described by this simple one-zone SSC model. However, the detection of $γ$-rays above 8 TeV during the flare challenges this model due to the hardness of the spectra. Correlations between X-rays and $γ$-rays are also investigated.

astro-ph.HE↗