SearcharxivSearch

arXiv subjects

R. Carney

Publications and source records attributed to R. Carney.

4 recordsLinked to original sources

A compact beta particle momentum detector

We present the design, development, and first calibration results of a compact beta electron detector for the Quantum Invisible Particle Sensor (QuIPS) experiment. The QuIPS electron detector is designed to reconstruct the full momentum vector of $\beta$ particles emitted from radioisotope-doped optically levitated nanospheres in ultra-high vacuum (UHV), enabling a measurement of the neutrino momentum and a search for heavy sterile neutrinos. The detector comprises two thinned CMOS detectors for directional tracking and a plastic scintillator read out by silicon photomultipliers (SiPMs) for calorimetry. The entire assembly must operate inside an existing optical trapping vacuum chamber at pressures below $10^{-7}$ mbar, imposing stringent constraints on material selection, power dissipation, outgassing, and compactness. We demonstrate sensitivity to $\beta$-decay electrons with energies as low as 100 keV and a detection efficiency of 35% above 500 keV, the primary window of interest for a heavy sterile neutrino search. The CMOS tracker resolves the momentum direction at the mrad scale and reconstructs the $\beta$ emission vertex with sub-mm precision, while the scintillator-SiPM system achieves an energy resolution of 5% at 1 MeV.

physics.ins-det

Development of hafnium-based transition edge sensor bolometers for cosmic microwave background polarimetry experiments

Next generation cosmic microwave background (CMB) polarimetry experiments aim to deploy order 500,000 detectors, requiring repeatable and reliable fabrication process with stable and uniform transition edge sensor (TES) bolometer performance. We present a hafnium (Hf)-based TES bolometer for CMB experiments. We employ a novel heated sputter deposition of the Hf films enabling us to finely tune the critical temperature (Tc) between 140 mK - 210 mK. We found elevated deposition temperatures result in films with lower stress, larger crystal sizes, and a smaller relative abundance of the m-plane to c-plane $\alpha$ phase, all contributing to the empirical linear dependence of critical temperature on deposition temperature. Crucially, the heated sputter deposition simultaneously ensures that the critical temperature does not drift despite exposure to heat throughout ongoing fab processes (sometimes reaching 350C) as long as the initial deposition temperature is not exceeded. Tcs lower than 170 mK require deposition temperature greater than 400C, far in excess of typical temperatures the wafer may experience. This ample thermal budget allows us to relax the stringent thermal management that conventional aluminum manganese (AlMn) TES bolometers require, for which temperatures as low as 200C - 250C are used to anneal the AlMn in an effort to adjust the Tc. Hf additionally exhibits an intrinsic steep superconducting transition (we measure $\alpha >$ 200) and a corresponding high loop gain (exceeding $\mathcal{L}>10$ deep in the transition). We precisely design the normal resistance of the TES to range between 10 milli-Ohm and 1 Ohm through an interdigitated geometry, making these TES bolometers compatible with both TDM, FDM, and $\mu$-mux readout systems. We report on bolometer parameters including critical temperature, normal resistance, saturation power, time constant, and loop gain.

physics.ins-det

LEGEND-1000 Preconceptual Design Report

We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless $\beta \beta$ Decay. This international experiment is designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the $^{76}$Ge isotope operated in a liquid argon active shield at a deep underground laboratory. By combining the lowest background levels with the best energy resolution in the field, LEGEND-1000 will perform a quasi-background-free search and can make an unambiguous discovery of neutrinoless double-beta decay with just a handful of counts at the decay $Q$ value. The experiment is designed to probe this decay with a 99.7%-CL discovery sensitivity in the $^{76}$Ge half-life of $1.3\times10^{28}$ years, corresponding to an effective Majorana mass upper limit in the range of 9-21 meV, to cover the inverted-ordering neutrino mass scale with 10 yr of live time.

physics.ins-det

Production and Integration of the ATLAS Insertable B-Layer

During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and integrated luminosities realised following the shutdown. Because of the extreme radiation and collision rate environment, several new radiation-tolerant sensor and electronic technologies were utilised for this layer. This paper reports on the IBL construction and integration prior to its operation in the ATLAS detector.

physics.ins-det