SearcharxivSearch

arXiv subjects

R. Chakraborty

Publications and source records attributed to R. Chakraborty.

15 recordsLinked to original sources

An improved direct limit on the muon electric dipole moment

A limit on the permanent electric dipole moment (EDM) of the positive muon is presented based on data from the Fermilab Muon g-2 Experiment taken between 2019 and 2020. The tracking detectors measure the average vertical decay angle of positrons from muon decays, enabling a search for an interaction between a possible muon EDM $d_\mu$ and the lab-frame magnetic field. The result, $d_\mu = (-0.35 \pm 0.19_{\mathrm{stat}} \pm 0.34_{\mathrm{sys}}) \times10^{-19}~e\cdot$cm, is consistent with zero and sets a new direct limit on the muon EDM of $|d_\mu|<1.10\times10^{-19}~e\cdot$cm at the 95 percent confidence level.

hep-ex

Final Report on the Measurement of the Positive Muon Anomalous Magnetic Moment at Fermilab to 127 ppb

This report details the final measurement of the muon magnetic anomaly, $a_{\mu}=(g_{\mu}-2)/2$, by the Muon $g-2$ experiment at Fermi National Accelerator Laboratory (FNAL), using positive muons collected from 2021 to 2023. The value of $a_{\mu}$ is determined from the ratio of the anomalous spin precession frequency to the shielded proton precession frequency in the muon storage ring magnetic field, combined with external constants known at the 22 ppb level. The new dataset, containing over $2.5$ times the statistics of our previous results, yields $a_{\mu}=116\,592\,0710(162)\times 10^{-12}$ (139 ppb), or $a_{\mu}=116\,592\,0705(148)\times 10^{-12}$ (127 ppb) when combined with our previous results. The new experimental world average, dominated by the measurements at FNAL, is $a_{\mu}^{\text{Exp}}=116\,592\,0715(145)\times 10^{-12}$ (124 ppb).

hep-ex

Measurement of the Positive Muon Anomalous Magnetic Moment to 127 ppb

A new measurement of the magnetic anomaly $a_μ$ of the positive muon is presented based on data taken from 2020 to 2023 by the Muon $g-2$ Experiment at Fermi National Accelerator Laboratory (FNAL). This dataset contains over 2.5 times the total statistics of our previous results. From the ratio of the precession frequencies for muons and protons in our storage ring magnetic field, together with precisely known ratios of fundamental constants, we determine $a_μ = 116\,592\,0710(162) \times 10^{-12}$ (139 ppb) for the new datasets, and $a_μ = 116\,592\,0705(148) \times 10^{-12}$ (127 ppb) when combined with our previous results. The new experimental world average, dominated by the measurements at FNAL, is $a_μ(\text{exp}) =116\,592\,0715(145) \times 10^{-12}$ (124 ppb). The measurements at FNAL have improved the precision on the world average by over a factor of four.

hep-ex

A compact frozen-spin trap for the search for the electric dipole moment of the muon

The electric dipole moments~(EDM) of fundamental particles inherently violate parity~(P) and time-reversal~(T) symmetries. By virtue of the CPT theorem in quantum field theory, the latter also implies the violation of the combined charge-conjugation and parity~(CP) symmetry. We aim to measure the EDM of the muon using the frozen-spin technique within a compact storage trap. This method exploits the high effective electric field, \$E \approx 165\$ MV/m, experienced in the rest frame of the muon with a momentum of about 23 MeV/c when it passes through a solenoidal magnetic field of \$|\vec{B}|=2.5\$ T. In this paper, we outline the fundamental considerations for a muon EDM search and present a conceptual design for a demonstration experiment to be conducted at secondary muon beamlines of the Paul Scherrer Institute in Switzerland. In Phase~I, with an anticipated data acquisition period of 200 days, the expected sensitivity to a muon EDM is 4E-21 ecm. In a subsequent phase, Phase~II, we propose to improve the sensitivity to 6E-23 ecm using a dedicated instrument installed on a different beamline that produces muons of momentum 125 MeV/c}.

hep-ex

Detailed Report on the Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm

We present details on a new measurement of the muon magnetic anomaly, $a_μ= (g_μ-2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$ GeV$/c$ polarized muons stored in a $7.1$-m-radius storage ring with a $1.45$ T uniform magnetic field. The value of $ a_μ$ is determined from the measured difference between the muon spin precession frequency and its cyclotron frequency. This difference is normalized to the strength of the magnetic field, measured using Nuclear Magnetic Resonance (NMR). The ratio is then corrected for small contributions from beam motion, beam dispersion, and transient magnetic fields. We measure $a_μ= 116 592 057 (25) \times 10^{-11}$ (0.21 ppm). This is the world's most precise measurement of this quantity and represents a factor of $2.2$ improvement over our previous result based on the 2018 dataset. In combination, the two datasets yield $a_μ(\text{FNAL}) = 116 592 055 (24) \times 10^{-11}$ (0.20 ppm). Combining this with the measurements from Brookhaven National Laboratory for both positive and negative muons, the new world average is $a_μ$(exp) $ = 116 592 059 (22) \times 10^{-11}$ (0.19 ppm).

hep-ex

Anomalous spin precession systematic effects in the search for a muon EDM using the frozen-spin technique

At the Paul Scherrer Institut (PSI), we are currently working on the development of a high-precision apparatus with the aim of searching for the muon electric dipole moment (EDM) with unprecedented sensitivity. The underpinning principle of this experiment is the frozen-spin technique, a method that suppresses the spin precession due to the anomalous magnetic moment, thereby enhancing the signal-to-noise ratio for EDM signals. This increased sensitivity facilitates measurements that would be difficult to achieve with conventional $g - 2$ muon storage rings. Given the availability of the $p = 125$ MeV/$c$ muon beam at PSI, the anticipated statistical sensitivity for the EDM after a year of data collection is $6\times 10^{-23}e\cdot$cm. To achieve this goal, it is imperative to meticulously analyse and mitigate any potential spurious effects that could mimic EDM signals. In this study, we present a quantitative methodology to evaluate the systematic effects that might arise in the context of employing the frozen-spin technique within a compact storage ring. Our approach entails the analytical derivation of equations governing the motion of the muon spin in the electromagnetic (EM) fields intrinsic to the experimental setup, validated through subsequent numerical simulations. We also illustrate a method to calculate the cumulative geometric (Berry's) phase. This work complements ongoing experimental efforts to detect a muon EDM at PSI and contributes to a broader understanding of spin-precession systematic effects.

hep-ex

Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm

We present a new measurement of the positive muon magnetic anomaly, $a_μ\equiv (g_μ- 2)/2$, from the Fermilab Muon $g\!-\!2$ Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, $\tildeω'^{}_p$, and of the anomalous precession frequency corrected for beam dynamics effects, $ω_a$. From the ratio $ω_a / \tildeω'^{}_p$, together with precisely determined external parameters, we determine $a_μ= 116\,592\,057(25) \times 10^{-11}$ (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain $a_μ\text{(FNAL)} = 116\,592\,055(24) \times 10^{-11}$ (0.20 ppm). The new experimental world average is $a_μ(\text{Exp}) = 116\,592\,059(22)\times 10^{-11}$ (0.19 ppm), which represents a factor of 2 improvement in precision.

hep-ex

Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab

The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_μ= (g^{}_μ-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7$^\circ$C. The measured field is weighted by the muon distribution resulting in $\tildeω'^{}_p$, the denominator in the ratio $ω^{}_a$/$\tildeω'^{}_p$ that together with known fundamental constants yields $a^{}_μ$. The reported uncertainty on $\tildeω'^{}_p$ for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, mapping, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb.

hep-ex

Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab

This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to $ω_a^m$ is 0.50 $\pm$ 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of $ω_a^m$.

physics.acc-ph

Measurement of the anomalous precession frequency of the muon in the Fermilab Muon g-2 experiment

The Muon g-2 Experiment at Fermi National Accelerator Laboratory (FNAL) has measured the muon anomalous precession frequency $ω_a$ to an uncertainty of 434 parts per billion (ppb), statistical, and 56 ppb, systematic, with data collected in four storage ring configurations during its first physics run in 2018. When combined with a precision measurement of the magnetic field of the experiment's muon storage ring, the precession frequency measurement determines a muon magnetic anomaly of $a_μ({\rm FNAL}) = 116\,592\,040(54) \times 10^{-11}$ (0.46 ppm). This article describes the multiple techniques employed in the reconstruction, analysis and fitting of the data to measure the precession frequency. It also presents the averaging of the results from the eleven separate determinations of ω_a, and the systematic uncertainties on the result.

hep-ex

Measurement of the Positive Muon Anomalous Magnetic Moment to 0.46 ppm

We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_μ\equiv (g_μ-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of high-energy positrons from muon decays directly encodes the difference frequency $ω_a$ between the spin-precession and cyclotron frequencies for polarized muons in a magnetic storage ring. The storage ring magnetic field is measured using nuclear magnetic resonance probes calibrated in terms of the equivalent proton spin precession frequency ${\tildeω'^{}_p}$ in a spherical water sample at 34.7$^{\circ}$C. The ratio $ω_a / {\tildeω'^{}_p}$, together with known fundamental constants, determines $a_μ({\rm FNAL}) = 116\,592\,040(54)\times 10^{-11}$ (0.46\,ppm). The result is 3.3 standard deviations greater than the standard model prediction and is in excellent agreement with the previous Brookhaven National Laboratory (BNL) E821 measurement. After combination with previous measurements of both $μ^+$ and $μ^-$, the new experimental average of $a_μ({\rm Exp}) = 116\,592\,061(41)\times 10^{-11}$ (0.35\,ppm) increases the tension between experiment and theory to 4.2 standard deviations

hep-ex

Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914

In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector's gravitational-wave response. The gravitational-wave response model is determined by the detector's opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz.

gr-qc

Numerical modeling of collisional dynamics of Sr in an optical dipole trap

We describe a model of inelastic and elastic collisional dynamics of atoms in an optical dipole trap that utilizes numerical evaluation of statistical mechanical quantities and numerical solution of equations for the evolution of number and temperature of trapped atoms. It can be used for traps that possess little spatial symmetry and when the ratio of trap depth to sample temperature is relatively small. We compare simulation results with experiments on $^{88}$Sr and $^{84}$Sr, which have well-characterized collisional properties.

physics.atom-ph

Inelastic and elastic collision rates for triplet states of ultracold strontium

We report measurement of the inelastic and elastic collision rates for ^{88}Sr atoms in the (5s5p)^3P_0 state in a crossed-beam optical dipole trap. This is the first measurement of ultracold collision properties of a ^3P_0 level in an alkaline-earth atom or atom with similar electronic structure. Since the (5s5p)^3P_0 state is the lowest level of the triplet manifold, large loss rates indicate the importance of principle-quantum-number-changing collisions at short range. We also provide an estimate of the collisional loss rates for the (5s5p){^3P_2} state.

physics.atom-ph

Quantum Entanglement, Cognition & The Processes of Inference

Church's hypothesis and Godel's theorem may provide constraints on mental processes.As a relief quantum entanglement may lead to a definite proposal as regards the nature of reality and how much of it we are able to know and how do we know it.We deal with these questions and have devised a Gedanken Experiment showing the redundancy of principle of reality. We thereby propose a model describing the processes of making conclusions from a given set of premises though without the reference of neurobiological processes at present. We argue thereafter that the physical laws of nature may not be universal as it seems, being dependent on some physical processes namely computation and the states of neural cognitive states which may be governed yet by some other rule.

physics.gen-ph