THGEM-based detectors for sampling elements in DHCAL: laboratory and beam evaluation

We report on the results of an extensive R&D program aimed at the evaluation of Thick-Gas Electron Multipliers (THGEM) as potential active elements for Digital Hadron Calorimetry (DHCAL). Results are presented on efficiency, pad multiplicity and discharge probability of a 10x10 cm2 prototype detector with 1 cm2 readout pads. The detector is comprised of single- or double-THGEM multipliers coupled to the pad electrode either directly or via a resistive anode. Investigations employing standard discrete electronics and the KPiX readout system have been carried out both under laboratory conditions and with muons and pions at the CERN RD51 test beam. For detectors having a charge-induction gap, it has been shown that even a ~6 mm thick single-THGEM detector reached detection efficiencies above 95%, with pad-hit multiplicity of 1.1-1.2 per event; discharge probabilities were of the order of 1e-6 - 1e-5 sparks/trigger, depending on the detector structure and gain. Preliminary beam tests with a WELL hole-structure, closed by a resistive anode, yielded discharge probabilities of <2e-6 for an efficiency of ~95%. Methods are presented to reduce charge-spread and pad multiplicity with resistive anodes. The new method showed good prospects for further evaluation of very thin THGEM-based detectors as potential active elements for DHCAL, with competitive performances, simplicity and robustness. Further developments are in course.

physics.ins-det

An Optical Readout TPC (O-TPC) for Studies in Nuclear Astrophysics With Gamma-Ray Beams at HIgS

We report on the construction, tests, calibrations and commissioning of an Optical Readout Time Projection Chamber (O-TPC) detector operating with a CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure the cross sections of several key nuclear reactions involved in stellar evolution. In particular, a study of the rate of formation of oxygen and carbon during the process of helium burning will be performed by exposing the chamber gas to intense nearly mono-energetic gamma-ray beams at the High Intensity Gamma Source (HIgS) facility. The O-TPC has a sensitive target-drift volume of 30x30x21 cm^3. Ionization electrons drift towards a double parallel grid avalanche multiplier, yielding charge multiplication and light emission. Avalanche induced photons from N2 emission are collected, intensified and recorded with a Charge Coupled Device (CCD) camera, providing two-dimensional track images. The event's time projection (third coordinate) and the deposited energy are recorded by photomultipliers and by the TPC charge-signal, respectively. A dedicated VME-based data acquisition system and associated data analysis tools were developed to record and analyze these data. The O-TPC has been tested and calibrated with 3.183 MeV alpha-particles emitted by a 148Gd source placed within its volume with a measured energy resolution of 3.0%. Tracks of alpha and 12C particles from the dissociation of 16O and of three alpha-particles from the dissociation of 12C have been measured during initial in-beam test experiments performed at the HIgS facility at Duke University. The full detection system and its performance are described and the results of the preliminary in-beam test experiments are reported.

physics.ins-det

The Thick-COBRA: a New Gaseous Electron Multiplier for Radiation Detectors

The operation principle and preliminary results of a novel gas-avalanche patterned hole electron multiplier, the Thick-COBRA (THCOBRA), are presented. This micro-hole structure is derived from the THGEM and MHSP. Sub-millimeter diameter holes are mechanically drilled in a thin G10 plate, Cu-clad on both faces; on one of the faces the Cu is etched to produce additional anode strips winding between circular cathode strips. Primary avalanches occurring within the holes are followed by additional ones at the anode-strips vicinity. Gains in excess of 5*104 were reached with 22.1 x-rays in Ar, Ne and Ar-10%CH4, with 12.2 % FWHM energy resolution in Ar-10%CH4. Higher gains were measured with single photoelectrons. This robust multiplier may have numerous potential applications.

physics.ins-det

Further evaluation of a THGEM UV-photon detector for RICH - comparison with MWPC

The operation of single-, double- and triple-THGEM UV-detectors with reflective CsI photocathodes (CsI-THGEM) in Ne/CH4 and Ne/CF4 mixtures was investigated in view of their potential applications in RICH. The studies were carried out with UV, x-rays and {\beta}-electrons and focused on the maximum achievable gain, discharge probability, cathode excitation effects and long-term gain stability. Comparative studies under similar conditions were made in CH4, CF4 and Ne/CF4, with a MWPC coupled to a reflective CsI photocathode (CsI-MWPC). It was found that at counting rates <= 10 Hz/mm^2 the maximum achievable gain of CsI-THGEMs is determined by the Raether limit; at counting rates > 10 Hz/mm^2 it dropped with rate. In all cases investigated the attainable CsI-THGEM gain was significantly higher than that of the CsI-MWPC, under similar conditions. Furthermore, the CsI-THGEM UV-detector suffered fewer cathode-excitation induced effects as compared to CsI-MWPC and had better stability at high counting rates.

physics.ins-det

Towards THGEM UV-photon detectors for RICH: on single-photon detection efficiency in Ne/CH4 and Ne/CF4

The article deals with the detection efficiency of UV-photon detectors consisting of Thick Gas Electron Multipliers (THGEM) coated with CsI photocathode, operated in atmospheric Ne/CH4 and Ne/CF4 mixtures. We report on the photoelectron extraction efficiency from the photocathode into these gas mixtures, and on the photoelectron collection efficiency into the THGEM holes. Full collection efficiency was reached in all gases investigated, in some cases at relatively low multiplication. High total detector gains for UV photons, in excess of 10^5, were reached at relatively low operation voltages with a single THGEM element. We discuss the photon detection efficiency in the context of possible application to RICH.

physics.ins-det

THGEM operation in Ne and Ne/CH4

The operation of Thick Gaseous Electron Multipliers (THGEM) in Ne and Ne/CH4 mixtures, features high multiplication factors at relatively low operation potentials, in both single- and double-THGEM configurations. We present some systematic data measured with UV-photons and soft x-rays, in various Ne mixtures. It includes gain dependence on hole diameter and gas purity, photoelectron extraction efficiency from CsI photocathodes into the gas, long-term gain stability and pulse rise-time. Position resolution of a 100x100 mm^2 X-rays imaging detector is presented. Possible applications are discussed.

physics.ins-det

Development of high-gain gaseous photomultipliers for the visible spectral range

We summarize the development of visible-sensitive gaseous photomultipliers, combining a semitransparent bi-alkali photocathode with a state-of-the-art cascaded electron multiplier. The latter has high photoelectron collection efficiency and a record ion blocking capability. We describe in details the system and methods of photocathode production and characterization, their coupling with the electron multiplier and the gaseous-photomultiplier operation and characterization in a continuous mode. We present results on the properties of laboratory-produced K$_2$CsSb, Cs$_3$Sb and Na$_2$KSb photocathodes and report on their stability and QE in gas; K$_2$CsSb photocathodes yielded QE values in Ar/CH$_4$(95/5) above 30% at wavelengths of 360-400 nm. The novel gaseous photomultiplier yielded stable operation at gains of 10$^5$, in continuous operation mode, in 700 Torr of this gas; its sensitivity to single photons was demonstrated. Other properties are described. The successful detection of visible light with this gas-photomultiplier pave ways towards further development of large-area sealed imaging detectors, of flat geometry, insensitive to magnetic fields, which might have significant impact on light detection in numerous fields.

physics.ins-det

Ion-induced secondary electron emission from K-Cs-Sb, Na-K-Sb and Cs-Sb photocathodes and its relevance to the operation of gaseous avalanche photomultipliers

The operation of visible-sensitive gaseous- and, to some extent, vacuum-photomultipliers is critically affected by secondary electrons originating from ion impact on the photocathode. A simple method for indirect measurement of the effective ion-induced secondary-electron emission (IISEE) coefficient from the photocathode into a gas medium, $γ_+^{eff}$ was developed. The experimental results with visible-sensitive K-Cs-Sb, Na-K-Sb and Cs-Sb photocathodes, yielded $γ_+^{eff}$ - values between 0.02 and 0.03 in Ar/CH$_{4}$ (95/5) at 700 mbar; these are in good agreement with theoretical calculations. The corresponding vacuum IISEE coefficients, $γ_+$, were estimated, based on a theoretical model, to be 0.47, 0.49 and 0.47 for K-Cs-Sb, Na-K-Sb and Cs-Sb photocathodes, respectively. The ratio of gas $γ_+^{eff}$ and vacuum $γ_+$ IISEE coefficients, calculated to be $\sim$0.06, is the fraction of secondary electrons surmounted the backscattering in the gas media.

physics.ins-det

High-gain DC-mode operated Gaseous Photomultipliers for the visible spectral range

We shortly describe recent progress in photon detectors combining bi-alkali photocathodes and cascaded patterned gas-avalanche electron multipliers. It permitted the development and the first feasibility demonstration of high-gain gaseous photomultipliers sensitive in the visible spectral range, operated in DC mode with single-photon sensitivity.

physics.ins-det

High pressure operation of the Photon-Assisted Cascaded Electron Multiplier

We present the operation of the recently introduced Photon Assisted Cascaded Electron Multiplier (PACEM) in xenon at high pressure. The PACEM is a multi step electron multiplier where the VUV scintillation produced in the electron avalanches is used for signal propagation: the VUV scintillation produced in the first element of the cascade induces the emission of photoelectrons from a CsI photocathode placed on the top-surface of the second element. These photoelectrons are further multiplied, via charge avalanche. A metallic mesh electrode placed between the first and the second elements of the cascade completely blocks the charge transfer between them. Optical gains of 103 were achieved in xenon at atmospheric pressure, dropping to 25 at 3.3 bar, for applied voltages of 700 and 1100 V, respectively. Taking into account the subsequent charge multiplication, total gains are higher than those obtained with a triple GEM and double THGEM.

physics.ins-det

Advances in Gaseous Photomultipliers

We review latest progress in gaseous photomultipliers (GPM) combining solid photocathodes and various types of novel electron multipliers. Cascaded gaseous electron multipliers (GEM) coated with CsI photocathodes can efficiently replace UVsensitive wire chambers for single-photon recording in Cherenkov and other detectors. Other hole-multipliers with patterned electrodes (Micro-Hole and Strip Plates) and improved ion-blocking properties are discussed; these permit reducing considerably photon- and ion-induced secondary effects. Photon detectors with other electron-multiplier techniques are briefly described, among them GPMs based on Micromegas, capillary-plates, Thick-GEMs and resistive Thick GEMs. The two latter techniques, robust and economically produced, are particularly suited for large-area GPM applications, e.g. in RICH. Cascaded hole-multipliers with very high ion-blocking performance permitted the development and the first demonstration of DC-operated visible-sensitive gaseous photomultipliers with bialkali photocathodes and single-photon sensitivity. Recent progress is described in GPMs operated at cryogenic temperatures for rare-event noble-liquid detectors and medical imaging.

physics.ins-det

A concise review on THGEM detectors

We briefly review the concept and properties of the Thick GEM (THGEM); it is a robust, high-gain gaseous electron multiplier, manufactured economically by standard printed-circuit drilling and etching technology. Its operation and structure resemble that of GEMs but with 5 to 20-fold expanded dimensions. The millimeter-scale hole-size results in good electron transport and in large avalanche-multiplication factors, e.g. reaching 10^7 in double-THGEM cascaded single-photoelectron detectors. The multiplier's material, parameters and shape can be application-tailored; it can operate practically in any counting gas, including noble gases, over a pressure range spanning from 1 mbar to several bars; its operation at cryogenic (LAr) conditions was recently demonstrated. The high gain, sub-millimeter spatial resolution, high counting-rate capability, good timing properties and the possibility of industrial production capability of large-area robust detectors, pave ways towards a broad spectrum of potential applications; some are discussed here in brief.

physics.ins-det

Efficient ion blocking in gaseous detectors and its application to gas-avalanche photomultipliers sensitive in the visible-light range

A novel concept for ion blocking in gas-avalanche detectors was developed, comprising cascaded micro-hole electron multipliers with patterned electrodes for ion defocusing. This leads to ion blocking at the 10^{-4} level, in DC mode, in operation conditions adequate for TPCs and for gaseous photomultipliers. The concept was validated in a cascaded visible-sensitive gas avalanche photomultiplier operating at atmospheric pressure of Ar/CH_{4} (95/5) with a bi-alkali photocathode. While in previous works high gain, in excess of 10^{5}, was reached only in a pulse-gated cascaded-GEM gaseous photomultiplier, the present device yielded, for the first time, similar gain in DC mode. We describe shortly the physical processes involved in the charge transport within gaseous photomultipliers and the ion blocking method. We present results of ion backflow fraction and of electron multiplication in cascaded patterned-electrode gaseous photomultiplier with K-Cs-Sb, Na-K-Sb and Cs-Sb visible-sensitive photocathodes, operated in DC mode.

physics.ins-det

Investigations of a THGEM-based imaging detector

We present the results of our recent studies on a Thick Gas Electron Multiplier (THGEM)-based imaging detector prototype. It consists of two 100x100 mm^2 THGEM electrodes in cascade, coupled to a resistive anode. The event location is recorded with a 2D double-sided readout electrode equipped with discrete delay-lines and dedicated electronics. The THGEM electrodes, produced by standard printed-circuit board and mechanical drilling techniques, a 0.4 mm thick with 0.5 mm diameter holes spaced by 1 mm. Localization resolutions of about 0.7 mm (FWHM) were measured with soft x-rays, in a detector operated with atmospheric-pressure Ar/CH4; good linearity and homogeneity were achieved. We describe the imaging-detector layout, the resistive-anode 2D readout system and the imaging properties. The THGEM has numerous potential applications that require large-area imaging detectors, with high-rate capability, single-electron sensitivity and moderate (sub-mm) localization resolution.

physics.ins-det

Operation of a Thick Gas Electron Multiplier (THGEM) in Ar, Xe and Ar-Xe

We present the results of our recent studies of a Thick Gaseous Electron Multiplier (THGEM)-based detector, operated in Ar, Xe and Ar:Xe (95:5) at various gas pressures. Avalanche-multiplication properties and energy resolution were investigated with soft x-rays for different detector configurations and parameters. Gains above 10E4 were reached in a double-THGEM detector, at atmospheric pressure, in all gases, in almost all the tested conditions; in Ar:Xe (95:5) similar gains were reached at pressures up to 2 bar. The energy resolution dependence on the gas, pressure, hole geometry and electric fields was studied in detail, yielding in some configurations values below 20% FWHM with 5.9 keV x-rays.

physics.ins-det

Further progress in ion back-flow reduction with patterned gaseous hole-multipliers

A new idea on electrostatic deviation and capture of back-drifting avalanche-ions in cascaded gaseous hole-multipliers is presented. It involves a flipped reversed-bias Micro-Hole & Strip Plate (F-R-MHSP) element, the strips of which are facing the drift region of the multiplier. The ions, originating from successive multiplication stages, are efficiently deviated and captured by such electrode. Experimental results are provided comparing the ion-blocking capability of the F-R-MHSP to that of the reversed-bias Micro-Hole & Strip Plate (R-MHSP) and the Gas Electron Multiplier (GEM). Best ion-blocking results in cascaded hole-multipliers were reached with a detector having the F-R-MHSP as the first multiplication element. A three-element F-R-MHSP/GEM/MHSP cascaded multiplier operated in atmospheric-pressure Ar/CH4 (95/5), at total gain of ~10^{5}, yielded ion back-flow fractions of 3*10^{-4} and 1.5*10^{-4}, at drift fields of 0.5 and 0.2 kV/cm, respectively. We describe the F-R-MHSP concept and the relevance of the obtained ion back-flow fractions to various applications; further ideas are also discussed.

physics.ins-det

Advances in ion back-flow reduction in cascaded gaseous electron multipliers incorporating R-MHSP elements

A new concept is presented for the reduction of ion back-flow in GEM-based cascaded gaseous electron multipliers, by incorporating Micro-Hole & Strip Plate (MHSP) elements operating in reversed-bias mode (R-MHSP). About an order of magnitude reduction in ion back-flow is achieved by diverting back-drifting ions from their original path. A R-MHSP/2GEM/MHSP cascaded multiplier operated at total gain of ~1.5*10^5 yielded ion back-flow fractions of 0.0015 and 0.0004, at drift fields of 0.5 and 0.1 kV/cm, respectively. A 2R-MHSP/MHSP cascaded multiplier operated at a total gain of ~10^5, yielded an ion back-flow fraction of 0.003. We discuss the concept for trapping back-flowing ions in these cascaded multipliers and the relevance to gaseous photomultiplier and TPC applications; directions for further future developments are outlined.

physics.ins-det