Searcharxiv⌕ Search

arXiv subjects

R. Ciuryło

Publications and source records attributed to R. Ciuryło.

13 recordsLinked to original sources

Spectrometry of Captured Highly Charged Ions Produced Following Antiproton Annihilations

We report a proof-of-principle study demonstrating the first capture and time-of-flight spectrometry of highly charged ions (HCIs) produced following antiproton annihilations in a Penning-Malmberg trap. A multi-step nested-trap technique was developed using the \aegis\ experiment to identify annihilation-linked captured ions. The trapping and spectrometry of helium and argon ions demonstrates the approach. This work establishes a foundation for the in-trap synthesis of radioactive HCIs and the study of cold nuclear annihilation fragments, with the long-term goal of enabling a sensitive tool for probing the outer nuclear periphery.

nucl-ex↗

New beyond-Voigt line-shape profile recommended for the HITRAN database

Parameters associated with the collisional perturbation of spectral lines are essential for modeling the absorption of electromagnetic radiation in gas media. The HITRAN molecular spectroscopic database provides these parameters, although originally they were associated only with the Voigt profile parameterization. However, in the HITRAN2016 and HITRAN2020 editions, Voigt, speed-dependent Voigt and Hartmann-Tran (HT) profiles have been incorporated, thanks to the new relational structure of the database. The HT profile was introduced in HITRAN in 2016 as a recommended profile for the most accurate spectral interpretations and modeling. It was parameterized with a four-temperature-range temperature dependence. Since then, however, some features of the HT profile have been revealed that are problematic from a practical perspective. These are: the singular behavior of the temperature dependencies of the velocity-changing parameters when the shift parameter crosses zero and the difficulty in evaluating the former for mixtures. In this article, we summarize efforts to eliminate the above-mentioned problems that led us to recommend using the quadratic speed-dependent hard-collision (qSDHC) profile with double-power-law (DPL) temperature dependencies. We refer to this profile as a modified Hartmann-Tran (mHT) profile. The computational cost of evaluating it is the same as for the HT profile. We give a detailed description of the mHT profile (also including line mixing) and discuss the representation of its parameters, together with their DPL temperature parametrization adopted in the HITRAN database. We discuss an efficient algorithm for evaluating this profile and provide corresponding computer codes in several programming languages: Fortran, Python, MATLAB, Wolfram Mathematica, and LabVIEW. We also discuss the associated update of the HITRAN Application Programming Interface (HAPI).

physics.atom-ph↗

TALOS (Total Automation of LabVIEW Operations for Science): A framework for autonomous control systems for complex experiments

Modern physics experiments are frequently very complex, relying on multiple simultaneous events to happen in order to obtain the desired result. The experiment control system plays a central role in orchestrating the measurement setup: However, its development is often treated as secondary with respect to the hardware, its importance becoming evident only during the operational phase. Therefore, the AEgIS (Antimatter Experiment: Gravity, Interferometry, Spectroscopy) collaboration has created a framework for easily coding control systems, specifically targeting atomic, quantum, and antimatter experiments. This framework, called Total Automation of LabVIEW Operations for Science (TALOS), unifies all the machines of the experiment in a single entity, thus enabling complex high-level decisions to be taken, and it is constituted by separate modules, called MicroServices, that run concurrently and asynchronously. This enhances the stability and reproducibility of the system while allowing for continuous integration and testing while the control system is running. The system demonstrated high stability and reproducibility, running completely unsupervised during the night and weekends of the data-taking campaigns. The results demonstrate the suitability of TALOS to manage an entire physics experiment in full autonomy: being open-source, experiments other than the AEgIS experiment can benefit from it.

physics.ins-det↗

Real-time antiproton annihilation vertexing with sub-micron resolution

The primary goal of the AEgIS experiment is to precisely measure the free fall of antihydrogen within Earth's gravitational field. To this end, a cold ~50K antihydrogen beam has to pass through two grids forming a moiré deflectometer before annihilating onto a position-sensitive detector, which shall determine the vertical position of the annihilation vertex relative to the grids with micrometric accuracy. Here we introduce a vertexing detector based on a modified mobile camera sensor and experimentally demonstrate that it can measure the position of antiproton annihilations with an accuracy of $0.62^{+0.40}_{-0.22}μm$, which represents a 35-fold improvement over the previous state-of-the-art for real-time antiproton vertexing. Importantly, these antiproton detection methods are directly applicable to antihydrogen. Moreover, the sensitivity to light of the sensor enables the in-situ calibration of the moiré deflectometer, significantly reducing systematic errors. This sensor emerges as a breakthrough technology for achieving the \aegis scientific goals and has been selected as the basis for the development of a large-area detector for conducting antihydrogen gravity measurements.

physics.ins-det↗

Positronium laser cooling via the $1^3S$-$2^3P$ transition with a broadband laser pulse

We report on laser cooling of a large fraction of positronium (Ps) in free-flight by strongly saturating the $1^3S$-$2^3P$ transition with a broadband, long-pulsed 243 nm alexandrite laser. The ground state Ps cloud is produced in a magnetic and electric field-free environment. We observe two different laser-induced effects. The first effect is an increase in the number of atoms in the ground state after the time Ps has spent in the long-lived $3^3P$ states. The second effect is the one-dimensional Doppler cooling of Ps, reducing the cloud's temperature from 380(20) K to 170(20) K. We demonstrate a 58(9) % increase in the coldest fraction of the Ps ensemble.

physics.atom-ph↗

Sub-promille measurements and calculations of CO (3--0) overtone line intensities

Intensities of lines in the near-infrared second overtone band (3--0) of $^{12}$C$^{16}$O are measured and calculated to an unprecedented degree of precision and accuracy. Agreement between theory and experiment to better than 1 $\permil$ is demonstrated by results from two laboratories involving two independent absorption- and dispersion-based cavity-enhanced techniques. Similarly, independent Fourier transform spectroscopy measurements of stronger lines in this band yield mutual agreement and consistency with theory at the 1 $\permil$ level. This set of highly accurate intensities can provide an intrinsic reference for reducing biases in future measurements of spectroscopic peak areas.

physics.chem-ph↗

Dual-comb cavity ring-down spectroscopy

Cavity ring-down spectroscopy is a ubiquitous optical method used to study light-matter interactions with high resolution, sensitivity and accuracy. However, it has never been performed with the multiplexing advantages of direct frequency comb spectroscopy without sacrificing orders of magnitude of resolution. We present dual-comb cavity ring-down spectroscopy (DC-CRDS) based on the parallel heterodyne detection of ring-down signals with a local oscillator comb to yield absorption and dispersion spectra. These spectra are obtained from widths and positions of cavity modes. We present two approaches which leverage the dynamic cavity response to coherently or randomly driven changes in the amplitude or frequency of the probe field. Both techniques yield accurate spectra of methane - an important greenhouse gas and breath biomarker. The high sensitivity and accuracy of broadband DC-CRDS, shows promise for applications like studies of the structure and dynamics of large molecules, multispecies trace gas detection and isotopic composition.

physics.optics↗

Ultra-high finesse cavity-enhanced spectroscopy for accurate tests of quantum electrodynamics for molecules

We report the most accurate measurement of the position of the weak quadrupole S(2) 2-0 line in D$_2$. The spectra were collected with a frequency-stabilized cavity ring-down spectrometer (FS-CRDS) with an ultra-high finesse optical cavity ($\mathcal{F}$ = 637 000) and operating in the frequency-agile, rapid scanning spectroscopy (FARS) mode. Despite working in the Doppler-limited regime, we reached 40 kHz of statistical uncertainty and 161 kHz of absolute accuracy, achieving the highest accuracy for homonuclear isotopologues of molecular hydrogen. The accuracy of our measurement corresponds to the fifth significant digit of the leading term in QED correction. We observe 2.3$σ$ discrepancy with the recent theoretical value.

physics.atom-ph↗

Cavity buildup dispersion spectroscopy

Measurements of ultrahigh-fidelity absorption spectra can help validate quantum theory, engineer ultracold chemistry, and remotely sense atmospheres. Recent achievements in cavity-enhanced spectroscopy using either frequency-based dispersion or time-based absorption approaches have set new records for accuracy with uncertainties at the sub-per-mil level. However, laser scanning5 or susceptibility to nonlinearities limits their ultimate performance. Here we present cavity buildup dispersion spectroscopy (CBDS) in which the dispersive frequency shift of a cavity resonance is encoded in the cavity's transient response to a phase-locked non-resonant laser excitation. Beating between optical frequencies during buildup exactly localizes detuning from mode center, and thus enables single-shot dispersion measurements. CBDS yields an accuracy limited by the chosen frequency standard, a speed limited by the cavity round-trip time, and is currently 50 times less susceptible to detection nonlinearity compared to intensity-based methods. The universality of CBDS shows promise for improving fundamental research into a variety of light-matter interactions.

physics.optics↗

Photoionization cross sections of the 5S${}_{1/2}$ and 5P${}_{3/2}$ states of Rb in simultaneous magneto-optical trapping of Rb and Hg

We report the measurement of the photoionization cross sections of the 5S${}_{1/2}$ and 5P${}_{3/2}$ states of ${}^{87}$Rb in a two-species Hg and Rb magneto-optical trap (MOT) by the cooling laser for Hg. The photoionization cross sections of Rb in the 5S${}_{1/2}$ and 5P${}_{3/2}$ states at 253.7~nm are determined to be $1^{+4.3}_{-1}\times10^{-20}~\text{cm}^2$ and $4.63(30)\times 10^{-18}\text{cm}^2$, respectively. To measure the 5S${}_{1/2}$ and 5P${}_{3/2}$ states fractions in the MOT we detected photoionization rate of the 5P${}_{3/2}$ state by an additional 401.5~nm laser. The photoionization cross section of Rb in the 5P${}_{3/2}$ state at 401.5~nm is determined to be $\text{1.18(10)}\times10^{-17}~\text{cm}^2$.

physics.atom-ph↗

First observation with global network of optical atomic clocks aimed for a dark matter detection

We report on the first earth-scale quantum sensor network based on optical atomic clocks aimed at dark matter (DM) detection. Exploiting differences in the susceptibilities to the fine-structure constant of essential parts of an optical atomic clock, i.e. the cold atoms and the optical reference cavity, we can perform sensitive searches for dark matter signatures without the need of real-time comparisons of the clocks. We report a two orders of magnitude improvement in constraints on transient variations of the fine-structure constant, which considerably improves the detection limit for the standard model (SM) - DM coupling. We use Yb and Sr optical atomic clocks at four laboratories on three continents to search for both topological defect (TD) and massive scalar field candidates. No signal consistent with a dark-matter coupling is identified, leading to significantly improved constraints on the DM-SM couplings.

physics.atom-ph↗

Fibre-optic delivery of time and frequency to VLBI station

The quality of Very Long Baseline Interferometry (VLBI) radio observations predominantly relies on precise and ultra-stable time and frequency (T&F) standards, usually hydrogen masers (HM), maintained locally at each VLBI station. Here, we present an operational solution in which the VLBI observations are routinely carried out without use of a local HM, but using remote synchronization via a stabilized, long-distance fibre-optic link. The T&F reference signals, traceable to international atomic timescale (TAI), are delivered to the VLBI station from a dedicated timekeeping laboratory. Moreover, we describe a proof-of-concept experiment where the VLBI station is synchronized to a remote strontium optical lattice clock during the observation.

astro-ph.IM↗

Strontium optical lattice clocks for practical realization of the metre and secondary representation of the second

We present a system of two independent strontium optical lattice standards probed with a single shared ultra-narrow laser. The absolute frequency of the clocks can be verified by the use of Er:fiber optical frequency comb with the GPS-disciplined Rb frequency standard. We report hertz-level spectroscopy of the clock line and measurements of frequency stability of the two strontium optical lattice clocks.

physics.atom-ph↗