SearcharxivSearch

arXiv subjects

R. Ferreira-Marques

Publications and source records attributed to R. Ferreira-Marques.

6 recordsLinked to original sources

Measurement and analysis of the Am-243 neutron capture cross section at the n_TOF facility at CERN

Background:The design of new nuclear reactors and transmutation devices requires to reduce the present neutron cross section uncertainties of minor actinides. Purpose: Reduce the $^{243}$Am(n,$γ$) cross section uncertainty. Method: The $^{243}$Am(n,$γ$) cross section has been measured at the n_TOF facility at CERN with a BaF$_{2}$ Total Absorption Calorimeter, in the energy range between 0.7 eV and 2.5 keV. Results: The $^{243}$Am(n,$γ$) cross section has been successfully measured in the mentioned energy range. The resolved resonance region has been extended from 250 eV up to 400 eV. In the unresolved resonance region our results are compatible with one of the two incompatible capture data sets available below 2.5 keV. The data available in EXFOR and in the literature has been used to perform a simple analysis above 2.5 keV. Conclusions: The results of this measurement contribute to reduce the $^{243}$Am(n,$γ$) cross section uncertainty and suggest that this cross section is underestimated up to 25% in the neutron energy range between 50 eV and a few keV in the present evaluated data libraries.

nucl-ex

Measurement of charged pions in 12C + 12C collisions at 1A GeV and 2A GeV with HADES

We present the results of a study of charged pion production in 12C + 12C collisions at incident beam energies of 1A GeV and 2A GeV using the HADES spectrometer at GSI. The main emphasis of the HADES program is on the dielectron signal from the early phase of the collision. Here, however, we discuss the data with respect to the emission of charged hadrons, specifically the production of pi+- mesons, which are related to neutral pions representing a dominant contribution to the dielectron yield. We have performed the first large-angular range measurement of the distribution of pi+- mesons for the 12C + 12C collision system covering a fairly large rapidity interval. The pion yields, transverse-mass and angular distributions are compared with calculations done within a transport model, as well as with existing data from other experiments. The anisotropy of pion production is systematically analyzed.

nucl-ex

Resistive plate chambers for time-of-flight measurements

The applications of Resistive Plate Chambers (RPCs) have recently been extended by the development of counters with time resolution below 100 ps sigma for minimum ionising particles. Applications to HEP experiments have already taken place and many further applications are under study. In this work we address the operating principles of such counters along with some present challenges, with emphasis on counter aging.

physics.ins-det

Perspectives for Positron Emission Tomography with RPCs

In this study we address the feasibility and main properties of a positron emission tomograph (PET) based on RPCs. The concept, making use of the converter-plate principle, takes advantage of the intrinsic layered structure of RPCs and its simple and economic construction. The extremely good time and position resolutions of RPCs also allow the TOF-PET imaging technique to be considered. Monte-Carlo simulations, supported by experimental data, are presented and the main advantages and drawbacks for applications of potential interest are discussed.

physics.ins-det

A Large Area Timing RPC

A large area Resistive Plate Chamber (RPC) with a total active surface of 160x10 cm2 was built and tested. The surface was segmented in two 5 cm wide strips readout on both ends with custom, very high frequency, front end electronics. A timing resolution between 50 and 75 ps sigma with an efficiency for Minimum Ionizing Particles (MIPs) larger than 95% was attained over the whole active area, in addition with a position resolution along the strips of 1.2 cm. Despite the large active area per electronic channel, the observed timing resolution is remarkably close to the one previously obtained (50 ps sigma) with much smaller chambers of about 10 cm2 area. These results open perspectives of extending the application of timing RPCs to large area arrays exposed to moderate particle multiplicities, where the low cost, good time resolution, insensitivity to the magnetic field and compact mechanics may be attractive when compared with the standard scintillator-based Time-of-Flight (TOF) technology.

physics.ins-det

Thin gap parallel mesh chamber: a sparkless high-rate detector

In this work we describe a parallel geometry gaseous detector constituted by a thin (0.6 mm) amplifying gap preceded by a drift region. The gap is delimited by a metal plate and by a wire mesh. The detector can count up to a rate of 10^7 Hz/mm2 at gain 1000 and retains at lower counting rates the high gains (close to 10^6) that are typical of parallel geometry detectors. Additionally it was found that in the thin amplifying gap the discharges seem to be self-quenched and that full sparks do not develop. This fact, together with the robustness of the electrode materials, makes this an extremely resilient high-rate detector.

physics.ins-det