SearcharxivSearch

arXiv subjects

R. Frühwirth

Publications and source records attributed to R. Frühwirth.

3 recordsLinked to original sources

Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data

A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six standard deviations, and the best measurement of its branching fraction so far. Furthermore, evidence for the $B^0\toμ^+μ^-$ decay is obtained with a statistical significance of three standard deviations. The branching fraction measurements are statistically compatible with SM predictions and impose stringent constraints on several theories beyond the SM.

hep-ex

Demonstrator of the Belle II Online Tracking and Pixel Data Reduction on the High Level Trigger System

The future Belle II experiment will employ a computer-farm based data reduction system for the readout of its innermost detector, a DEPFET-technology based silicon detector with pixel readout. A large fraction of the background hits can be rejected by defining a set of Regions Of Interest (ROI) on the pixel detector sensors and then recording just the data from the pixels inside the ROI. The ROIs are defined on an event by event basis by extrapolating back onto the PXD the charged tracks detected in the outer trackers (a 4 layer double-sided silicon strip detector surrounded by a wire chamber). The tracks are reconstructed in real time on the High Level Trigger (HLT). The pixel detector is then read out based on the ROI information. A demonstrator of this architecture was under beam test earlier this year in DESY (Hamburg, Germany). The demonstrator was operated in an electron beam whose momentum was in the 2-6 GeV/c range with a typical trigger rate of a few kHz in a magnetic field of strength up to 1 T. The demonstrator consists of one pixel sensor and 4 silicon strip sensors arranged in a 5 layers configuration mimicking the Belle II vertex detector. The detector readout was a scaled down version of the full Belle II DAQ + HLT chain. The demonstrator was used to detect the particles, reconstruct in real time the trajectories, identify the ROIs on the PXD plane and record the PXD data within. We describe the requirements and the architecture of the final system together with the results obtained with the demonstrator.

physics.ins-det

Reconstruction of electrons with the Gaussian-sum filter in the CMS tracker at LHC

The bremsstrahlung energy loss distribution of electrons propagating in matter is highly non Gaussian. Because the Kalman filter relies solely on Gaussian probability density functions, it might not be an optimal reconstruction algorithm for electron tracks. A Gaussian-sum filter (GSF) algorithm for electron track reconstruction in the CMS tracker has therefore been developed. The basic idea is to model the bremsstrahlung energy loss distribution by a Gaussian mixture rather than a single Gaussian. It is shown that the GSF is able to improve the momentum resolution of electrons compared to the standard Kalman filter. The momentum resolution and the quality of the estimated error are studied with various types of mixture models of the energy loss distribution.

physics.data-an