SearcharxivSearch

arXiv subjects

R. Gouaty

Publications and source records attributed to R. Gouaty.

8 recordsLinked to original sources

Reconstruction of the gravitational wave signal $h(t)$ during the Virgo science runs and independent validation with a photon calibrator

The Virgo detector is a kilometer-scale interferometer for gravitational wave detection located near Pisa (Italy). About 13 months of data were accumulated during four science runs (VSR1, VSR2, VSR3 and VSR4) between May 2007 and September 2011, with increasing sensitivity. In this paper, the method used to reconstruct, in the range 10 Hz-10 kHz, the gravitational wave strain time series $h(t)$ from the detector signals is described. The standard consistency checks of the reconstruction are discussed and used to estimate the systematic uncertainties of the $h(t)$ signal as a function of frequency. Finally, an independent setup, the photon calibrator, is described and used to validate the reconstructed $h(t)$ signal and the associated uncertainties. The uncertainties of the $h(t)$ time series are estimated to be 8% in amplitude. The uncertainty of the phase of $h(t)$ is 50 mrad at 10 Hz with a frequency dependence following a delay of 8 $μ$s at high frequency. A bias lower than $4\,\mathrm{μs}$ and depending on the sky direction of the GW is also present.

gr-qc

Scientific Objectives of Einstein Telescope

The advanced interferometer network will herald a new era in observational astronomy. There is a very strong science case to go beyond the advanced detector network and build detectors that operate in a frequency range from 1 Hz-10 kHz, with sensitivity a factor ten better in amplitude. Such detectors will be able to probe a range of topics in nuclear physics, astronomy, cosmology and fundamental physics, providing insights into many unsolved problems in these areas.

gr-qc

Characterization of the Virgo Seismic Environment

The Virgo gravitational wave detector is an interferometer (ITF) with 3km arms located in Pisa, Italy. From July to October 2010, Virgo performed its third science run (VSR3) in coincidence with the LIGO detectors. Despite several techniques adopted to isolate the interferometer from the environment, seismic noise remains an important issue for Virgo. Vibrations produced by the detector infrastructure (such as air conditioning units, water chillers/heaters, pumps) are found to affect Virgo's sensitivity, with the main coupling mechanisms being through beam jitter and scattered light processes. The Advanced Virgo (AdV) design seeks to reduce ITF couplings to environmental noise by having most vibration-sensitive components suspended and in-vacuum, as well as muffle and relocate loud machines. During the months of June and July 2010, a Guralp-3TD seismometer was stationed at various locations around the Virgo site hosting major infrastructure machines. Seismic data were examined using spectral and coherence analysis with seismic probes close to the detector. The primary aim of this study was to identify noisy machines which seismically affect the ITF environment and thus require mitigation attention. Analyzed machines are located at various distances from the experimental halls, ranging from 10m to 100m. An attempt is made to measure the attenuation of emitted noise at the ITF and correlate it to the distance from the source and to seismic attenuation models in soil.

gr-qc

Calibration and sensitivity of the Virgo detector during its second science run

The Virgo detector is a kilometer-length interferometer for gravitational wave detection located near Pisa (Italy). During its second science run (VSR2) in 2009, six months of data were accumulated with a sensitivity close to its design. In this paper, the methods used to determine the parameters for sensitivity estimation and gravitational wave reconstruction are described. The main quantities to be calibrated are the frequency response of the mirror actuation and the sensing of the output power. Focus is also put on their absolute timing. The monitoring of the calibration data as well as the parameter estimation with independent techniques are discussed to provide an estimation of the calibration uncertainties. Finally, the estimation of the Virgo sensitivity in the frequency-domain is described and typical sensitivities measured during VSR2 are shown.

gr-qc

Virgo calibration and reconstruction of the gravitational wave strain during VSR1

Virgo is a kilometer-length interferometer for gravitational waves detection located near Pisa. Its first science run, VSR1, occured from May to October 2007. The aims of the calibration are to measure the detector sensitivity and to reconstruct the time series of the gravitational wave strain h(t). The absolute length calibration is based on an original non-linear reconstruction of the differential arm length variations in free swinging Michelson configurations. It uses the laser wavelength as length standard. This method is used to calibrate the frequency dependent response of the Virgo mirror actuators and derive the detector in-loop response and sensitivity within ~5%. The principle of the strain reconstruction is highlighted and the h(t) systematic errors are estimated. A photon calibrator is used to check the sign of h(t). The reconstructed h(t) during VSR1 is valid from 10 Hz up to 10 kHz with systematic errors estimated to 6% in amplitude. The phase error is estimated to be 70 mrad below 1.9 kHz and 6 micro-seconds above.

gr-qc

Detection Confidence Tests for Burst and Inspiral Candidate Events

The LIGO Scientific Collaboration (LSC) is developing and running analysis pipelines to search for gravitational-wave transients emitted by astrophysical events such as compact binary mergers or core-collapse supernovae. However, because of the non-Gaussian, non-stationary nature of the noise exhibited by the LIGO detectors, residual false alarms might be found at the end of the pipelines. A critical aspect of the search is then to assess our confidence for gravitational waves and to distinguish them from those false alarms. Both the 'Compact Binary Coalescence' and the 'Burst' working groups have been developing a detection checklist for the validation of candidate-events, consisting of a series of tests which aim to corroborate a detection or to eliminate a false alarm. These tests include for example data quality checks, analysis of the candidate appearance, parameter consistency studies and coherent analysis. In this paper, the general methodology used for candidate validation is presented. The method is illustrated with an example of simulated gravitational-wave signal and a false alarm.

gr-qc

The LSC Glitch Group : Monitoring Noise Transients during the fifth LIGO Science Run

The LIGO Scientific Collaboration (LSC) glitch group is part of the LIGO detector characterization effort. It consists of data analysts and detector experts who, during and after science runs, collaborate for a better understanding of noise transients in the detectors. Goals of the glitch group during the fifth LIGO science run (S5) included (1) offline assessment of the detector data quality, with focus on noise transients, (2) veto recommendations for astrophysical analysis and (3) feedback to the commissioning team on anomalies seen in gravitational wave and auxiliary data channels. Other activities included the study of auto-correlation of triggers from burst searches, stationarity of the detector noise and veto studies. The group identified causes for several noise transients that triggered false alarms in the gravitational wave searches; the times of such transients were identified and vetoed from the data generating the LSC astrophysical results.

gr-qc

Variable placement of templates technique in a 2D parameter space for binary inspiral searches

In the search for binary systems inspiral signal in interferometric gravitational waves detectors, one needs the generation and placement of a grid of templates. We present an original technique for the placement in the associated parameter space, that makes use of the variation of size of the isomatch ellipses in order to reduce the number of templates necessary to cover the parameter space. This technique avoids the potentially expensive computation of the metric at every point, at the cost of having a small number of ``holes'' in the coverage, representing a few percent of the surface of the parameter space, where the match is slightly lower than specified. A study of the covering efficiency, as well as a comparison with a very simple regular tiling using a single ellipse is made. Simulations show an improvement varying between 6% and 30% for the computing cost in this comparison.

gr-qc