Searcharxiv⌕ Search

arXiv subjects

R. Guenette

Publications and source records attributed to R. Guenette.

At least 73 records · Page 4Linked to original sources

Measurement of ambient radon progeny decay rates and energy spectra in liquid argon using the MicroBooNE detector

We report measurements of radon progeny in liquid argon within the MicroBooNE time projection chamber (LArTPC). The presence of specific radon daughters in MicroBooNE's 85 metric tons of active liquid argon bulk is probed with newly developed charge-based low-energy reconstruction tools and analysis techniques to detect correlated $^{214}$Bi-$^{214}$Po radioactive decays. Special datasets taken during periods of active radon doping enable new demonstrations of the calorimetric capabilities of single-phase neutrino LArTPCs for $β$ and $α$ particles with electron-equivalent energies ranging from 0.1 to 3.0 MeV. By applying $^{214}$Bi-$^{214}$Po detection algorithms to data recorded over a 46-day period, no statistically significant presence of radioactive $^{214}$Bi is detected, and a limit on the activity is placed at $<0.35$ mBq/kg at the 95% confidence level. This bulk $^{214}$Bi radiopurity limit -- the first ever reported for a liquid argon detector incorporating liquid-phase purification -- is then further discussed in relation to the targeted upper limit of 1 mBq/kg on bulk $^{222}$Rn activity for the DUNE neutrino detector.

hep-ex↗

Search for heavy neutral leptons in electron-positron and neutral-pion final states with the MicroBooNE detector

We present the first search for heavy neutral leptons (HNL) decaying into $νe^+e^-$ or $νπ^0$ final states in a liquid-argon time projection chamber using data collected with the MicroBooNE detector. The data were recorded synchronously with the NuMI neutrino beam from Fermilab's Main Injector corresponding to a total exposure of $7.01 \times 10^{20}$ protons on target. We set upper limits at the $90\%$ confidence level on the mixing parameter $\lvert U_{μ4}\rvert^2$ in the mass ranges $10\le m_{\rm HNL}\le 150$ MeV for the $νe^+e^-$ channel and $150\le m_{\rm HNL}\le 245$ MeV for the $νπ^0$ channel, assuming $\lvert U_{e 4}\rvert^2 = \lvert U_{τ4}\rvert^2 = 0$. These limits represent the most stringent constraints in the mass range $35<m_{\rm HNL}<175$ MeV and the first constraints from a direct search for $νπ^0$ decays.

hep-ex↗

Design, characterization and installation of the NEXT-100 cathode and electroluminescence regions

NEXT-100 is currently being constructed at the Laboratorio Subterráneo de Canfranc in the Spanish Pyrenees and will search for neutrinoless double beta decay using a high-pressure gaseous time projection chamber (TPC) with 100 kg of xenon. Charge amplification is carried out via electroluminescence (EL) which is the process of accelerating electrons in a high electric field region causing secondary scintillation of the medium proportional to the initial charge. The NEXT-100 EL and cathode regions are made from tensioned hexagonal meshes of 1 m diameter. This paper describes the design, characterization, and installation of these parts for NEXT-100. Simulations of the electric field are performed to model the drift and amplification of ionization electrons produced in the detector under various EL region alignments and rotations. Measurements of the electrostatic breakdown voltage in air characterize performance under high voltage conditions and identify breakdown points. The electrostatic deflection of the mesh is quantified and fit to a first-principles mechanical model. Measurements were performed with both a standalone test EL region and with the NEXT-100 EL region before its installation in the detector. Finally, we describe the parts as installed in NEXT-100, following their deployment in Summer 2023.

physics.ins-det↗

Demonstration of Event Position Reconstruction based on Diffusion in the NEXT-White Detector

Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift distance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high- and low-energy events. Using point-like energy deposits from $^{83\mathrm{m}}$Kr calibration electron captures ($E\sim45$keV), the position of origin of low-energy events is determined to $2~$cm precision with bias $< 1$mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks (E$\geq$1.5MeV), yielding a precision of 3cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Q$_{ββ}$ in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation.

hep-ex↗

Demonstration of neutrinoless double beta decay searches in gaseous xenon with NEXT

The NEXT experiment aims at the sensitive search of the neutrinoless double beta decay in $^{136}$Xe, using high-pressure gas electroluminescent time projection chambers. The NEXT-White detector is the first radiopure demonstrator of this technology, operated in the Laboratorio Subterráneo de Canfranc. Achieving an energy resolution of 1% FWHM at 2.6 MeV and further background rejection by means of the topology of the reconstructed tracks, NEXT-White has been exploited beyond its original goals in order to perform a neutrinoless double beta decay search. The analysis considers the combination of 271.6 days of $^{136}$Xe-enriched data and 208.9 days of $^{136}$Xe-depleted data. A detailed background modeling and measurement has been developed, ensuring the time stability of the radiogenic and cosmogenic contributions across both data samples. Limits to the neutrinoless mode are obtained in two alternative analyses: a background-model-dependent approach and a novel direct background-subtraction technique, offering results with small dependence on the background model assumptions. With a fiducial mass of only 3.50$\pm$0.01 kg of $^{136}$Xe-enriched xenon, 90% C.L. lower limits to the neutrinoless double beta decay are found in the T$_{1/2}^{0ν}>5.5\times10^{23}-1.3\times10^{24}$ yr range, depending on the method. The presented techniques stand as a proof-of-concept for the searches to be implemented with larger NEXT detectors.

nucl-ex↗

First demonstration of $\mathcal{O}(1\,\text{ns})$ timing resolution in the MicroBooNE liquid argon time projection chamber

MicroBooNE is a neutrino experiment located in the Booster Neutrino Beamline (BNB) at Fermilab, which collected data from 2015 to 2021. MicroBooNE's liquid argon time projection chamber (LArTPC) is accompanied by a photon detection system consisting of 32 photomultiplier tubes used to measure the argon scintillation light and determine the timing of neutrino interactions. Analysis techniques combining light signals and reconstructed tracks are applied to achieve a neutrino interaction time resolution of $\mathcal{O}(1\,\text{ns})$. The result obtained allows MicroBooNE to access the ns neutrino pulse structure of the BNB for the first time. The timing resolution achieved will enable significant enhancement of cosmic background rejection for all neutrino analyses. Furthermore, the ns timing resolution opens new avenues to search for long-lived-particles such as heavy neutral leptons in MicroBooNE, as well as in future large LArTPC experiments, namely the SBN program and DUNE.

hep-ex↗

A Method To Characterize Metalenses For Light Collection Applications

Metalenses and metasurfaces are promising emerging technologies that could improve light collection in light collection detectors, concentrating light on small area photodetectors such as silicon photomultipliers. Here we present a detailed method to characterize metalenses to assess their efficiency at concentrating monochromatic light coming from a wide range of incidence angles, not taking into account their imaging quality.

physics.app-ph↗

NEXT-CRAB-0: A High Pressure Gaseous Xenon Time Projection Chamber with a Direct VUV Camera Based Readout

The search for neutrinoless double beta decay ($0νββ$) remains one of the most compelling experimental avenues for the discovery in the neutrino sector. Electroluminescent gas-phase time projection chambers are well suited to $0νββ$ searches due to their intrinsically precise energy resolution and topological event identification capabilities. Scalability to ton- and multi-ton masses requires readout of large-area electroluminescent regions with fine spatial resolution, low radiogenic backgrounds, and a scalable data acquisition system. This paper presents a detector prototype that records event topology in an electroluminescent xenon gas TPC via VUV image-intensified cameras. This enables an extendable readout of large tracking planes with commercial devices that reside almost entirely outside of the active medium.Following further development in intermediate scale demonstrators, this technique may represent a novel and enlargeable method for topological event imaging in $0νββ$.

physics.ins-det↗

First measurement of quasi-elastic $Λ$ baryon production in muon anti-neutrino interactions in the MicroBooNE detector

We present the first measurement of the cross section of Cabibbo-suppressed $Λ$ baryon production, using data collected with the MicroBooNE detector when exposed to the neutrinos from the Main Injector beam at the Fermi National Accelerator Laboratory. The data analyzed correspond to $2.2 \times 10^{20}$ protons on target of neutrino mode running and $4.9 \times 10^{20}$ protons on target of anti-neutrino mode running. An automated selection is combined with hand scanning, with the former identifying five candidate $Λ$ production events when the signal was unblinded, consistent with the GENIE prediction of $5.3 \pm 1.1$ events. Several scanners were employed, selecting between three and five events, compared with a prediction from a blinded Monte Carlo simulation study of $3.7 \pm 1.0$ events. Restricting the phase space to only include $Λ$ baryons that decay above MicroBooNE's detection thresholds, we obtain a flux averaged cross section of $2.0^{+2.2}_{-1.7} \times 10^{-40}$ cm$^2/$Ar, where statistical and systematic uncertainties are combined.

hep-ex↗

A Compact Dication Source for Ba$^{2+}$ Tagging and Heavy Metal Ion Sensor Development

We present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cobalt samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean $\mathrm{Ba^{2+}}$ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb$^{2+}$ and Cd$^{2+}$ also demonstrated for this purpose.

physics.ins-det↗

Reflectance and fluorescence characteristics of PTFE coated with TPB at visible, UV, and VUV as a function of thickness

Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. In noble element systems, it is often coated with tetraphenyl butadiene (TPB) to allow detection of vacuum ultraviolet scintillation light. In this work this dependence is investigated for PTFE coated with TPB in air for light of wavelengths of 200~nm, 260~nm, and 450~nm. The results show that TPB-coated PTFE has a reflectance of approximately 92\% for thicknesses ranging from 5~mm to 10~mm at 450~nm, with negligible variation as a function of thickness within this range. A cross-check of these results using an argon chamber supports the conclusion that the change in thickness from 5~mm to 10~mm does not affect significantly the light response at 128~nm. Our results indicate that pieces of TPB-coated PTFE thinner than the typical 10~mm can be used in particle physics detectors without compromising the light signal.

physics.ins-det↗

Measurement of neutral current single $π^0$ production on argon with the MicroBooNE detector

We report the first measurement of $π^0$ production in neutral current (NC) interactions on argon with average neutrino energy of $\lesssim1$~GeV. We use data from the MicroBooNE detector's 85-tonne active volume liquid argon time projection chamber situated in Fermilab's Booster Neutrino Beam and exposed to $5.89\times10^{20}$ protons on target for this measurement. Measurements of NC $π^0$ events are reported for two exclusive event topologies without charged pions. Those include a topology with two photons from the decay of the $π^0$ and one proton and a topology with two photons and zero protons. Flux-averaged cross-sections for each exclusive topology and for their semi-inclusive combination are extracted (efficiency-correcting for two-plus proton final states), and the results are compared to predictions from the \textsc{genie}, \textsc{neut}, and \textsc{NuWro} neutrino event generators. We measure cross sections of $1.243\pm0.185$ (syst) $\pm0.076$ (stat), $0.444\pm0.098\pm0.047$, and $0.624\pm0.131\pm0.075$ $[10^{-38}\textrm{cm}^2/\textrm{Ar}]$ for the semi-inclusive NC$π^0$, exclusive NC$π^0$+1p, and exclusive NC$π^0$+0p processes, respectively.

hep-ex↗

Search for long-lived heavy neutral leptons and Higgs portal scalars decaying in the MicroBooNE detector

We present a search for long-lived Higgs portal scalars (HPS) and heavy neutral leptons (HNL) decaying in the MicroBooNE liquid-argon time projection chamber. The measurement is performed using data collected synchronously with the NuMI neutrino beam from Fermilab's Main Injector with a total exposure corresponding to $7.01 \times 10^{20}$ protons on target. We set upper limits at the $90\%$ confidence level on the mixing parameter $\lvert U_{μ4}\rvert^2$ ranging from $\lvert U_{μ4}\rvert^2<12.9\times 10^{-8}$ for Majorana HNLs with a mass of $m_{\rm HNL}=246$ MeV to $\lvert U_{μ4}\rvert^2<0.92 \times 10^{-8}$ for $m_{\rm HNL}=385$ MeV, assuming $\lvert U_{e 4}\rvert^2 = \lvert U_{τ4}\rvert^2 = 0$ and HNL decays into $μ^\pmπ^\mp$ pairs. These limits on $\lvert U_{μ4}\rvert^2$ represent an order of magnitude improvement in sensitivity compared to the previous MicroBooNE result. We also constrain the scalar-Higgs mixing angle $θ$ by searching for HPS decays into $μ^+μ^-$ final states, excluding a contour in the parameter space with lower bounds of $θ^2<31.3 \times 10^{-9}$ for $m_{\rm HPS}=212$ GeV and $θ^2<1.09 \times 10^{-9}$ for $m_{\rm HPS}=275$ GeV. These are the first constraints on the scalar-Higgs mixing angle $θ$ from a dedicated experimental search in this mass range.

hep-ex↗

First constraints on light sterile neutrino oscillations from combined appearance and disappearance searches with the MicroBooNE detector

We present a search for eV-scale sterile neutrino oscillations in the MicroBooNE liquid argon detector, simultaneously considering all possible appearance and disappearance effects within the $3+1$ active-to-sterile neutrino oscillation framework. We analyze the neutrino candidate events for the recent measurements of charged-current $ν_e$ and $ν_μ$ interactions in the MicroBooNE detector, using data corresponding to an exposure of 6.37$\times$10$^{20}$ protons on target from the Fermilab booster neutrino beam. We observe no evidence of light sterile neutrino oscillations and derive exclusion contours at the $95\%$ confidence level in the plane of the mass-squared splitting $Δm^2_{41}$ and the sterile neutrino mixing angles $θ_{μe}$ and $θ_{ee}$, excluding part of the parameter space allowed by experimental anomalies. Cancellation of $ν_e$ appearance and $ν_e$ disappearance effects due to the full $3+1$ treatment of the analysis leads to a degeneracy when determining the oscillation parameters, which is discussed in this paper and will be addressed by future analyses.

hep-ex↗

Observation of Radon Mitigation in MicroBooNE by a Liquid Argon Filtration System

The MicroBooNE liquid argon time projection chamber (LArTPC) maintains a high level of liquid argon purity through the use of a filtration system that removes electronegative contaminants in continuously-circulated liquid, recondensed boil off, and externally supplied argon gas. We use the MicroBooNE LArTPC to reconstruct MeV-scale radiological decays. Using this technique we measure the liquid argon filtration system's efficacy at removing radon. This is studied by placing a 500 kBq $^{222}$Rn source upstream of the filters and searching for a time-dependent increase in the number of radiological decays in the LArTPC. In the context of two models for radon mitigation via a liquid argon filtration system, a slowing mechanism and a trapping mechanism, MicroBooNE data supports a radon reduction factor of greater than 99.999% or 97%, respectively. Furthermore, a radiological survey of the filters found that the copper-based filter material was the primary medium that removed the $^{222}$Rn. This is the first observation of radon mitigation in liquid argon with a large-scale copper-based filter and could offer a radon mitigation solution for future large LArTPCs.

physics.ins-det↗

Enhanced low-energy supernova burst detection in large liquid argon time projection chambers enabled by Q-Pix

The detection of neutrinos from core-collapse supernovae may reveal important process features as well as neutrino properties. The detection of supernova neutrinos is one of the main science drivers for future kiloton-scale neutrino detectors based on liquid argon. Here we show that for such detectors the intrinsically 3D readout in Q-Pix offers numerous advantages relative to a wire-based readout, such as higher reconstruction efficiency, lower energy threshold, considerably lower data rates, and potential pointing information.

hep-ex↗

Differential cross section measurement of charged current $ν_{e}$ interactions without final-state pions in MicroBooNE

In this letter we present the first measurements of an exclusive electron neutrino cross section with the MicroBooNE experiment using data from the Booster Neutrino Beamline at Fermilab. These measurements are made for a selection of charged-current electron neutrinos without final-state pions. Differential cross sections are extracted in energy and angle with respect to the beam for the electron and the leading proton. The differential cross section as a function of proton energy is measured using events with protons both above and below the visibility threshold. This is done by including a separate selection of electron neutrino events without reconstructed proton candidates in addition to those with proton candidates. Results are compared to the predictions from several modern generators, and we find the data agrees well with these models. The data shows best agreement, as quantified by $p$-value, with the generators that predict a lower overall cross section, such as GENIE v3 and NuWro.

hep-ex↗

Search for an anomalous excess of charged-current quasi-elastic $ν_e$ interactions with the MicroBooNE experiment using Deep-Learning-based reconstruction

We present a measurement of the $ν_e$-interaction rate in the MicroBooNE detector that addresses the observed MiniBooNE anomalous low-energy excess (LEE). The approach taken isolates neutrino interactions consistent with the kinematics of charged-current quasi-elastic (CCQE) events. The topology of such signal events has a final state with 1 electron, 1 proton, and 0 mesons ($1e1p$). Multiple novel techniques are employed to identify a $1e1p$ final state, including particle identification that use two methods of deep-learning-based image identification, and event isolation using a boosted decision-tree ensemble trained to recognize two-body scattering kinematics. This analysis selects 25 $ν_e$-candidate events in the reconstructed neutrino energy range of 200--1200\,MeV, while $29.0 \pm 1.9_\text{(sys)} \pm 5.4_\text{(stat)}$ are predicted when using $ν_μ$ CCQE interactions as a constraint. We use a simplified model to translate the MiniBooNE LEE observation into a prediction for a $ν_e$ signal in MicroBooNE. A $Δχ^2$ test statistic, based on the combined Neyman--Pearson $χ^2$ formalism, is used to define frequentist confidence intervals for the LEE signal strength. Using this technique, in the case of no LEE signal, we expect this analysis to exclude a normalization factor of 0.75 (0.98) times the median MiniBooNE LEE signal strength at 90\% ($2σ$) confidence level, while the MicroBooNE data yield an exclusion of 0.25 (0.38) times the median MiniBooNE LEE signal strength at 90\% ($2σ$) confidence

hep-ex↗