SearcharxivSearch

arXiv subjects

R. H. Menk

Publications and source records attributed to R. H. Menk.

8 recordsLinked to original sources

Development & first Performance evaluation of multi-element monolithic HPGe detector for X-ray spectroscopy

The first operational prototype of a high-purity Germanium (HPGe) detector developed within the European LEAPS-INNOV project is presented in this work. This prototype features a monolithic, multi-element sensor optimized for high-resolution X-ray spectroscopy in the hard X-ray regime, capable of handling high count rates (20-250 kcps/mm2) across a broad energy range (5-100 keV). We discuss here a complete laboratory-based characterization of the detector's performance, as well as an on-beam evaluation at the BM05 beamline of the ESRF synchrotron facility, using monochromatic X-rays in the 20-50 keV energy range. We provide a detailed performance assessment that also includes a phenomenological defect-depth estimation model.

physics.ins-det

Laboratory and Synchrotron Validation of $\mu$-XRF for Sulfur Mapping in CTMP Paper Samples

The transition toward renewable, fiber-based packaging requires an improved understanding of chemical modifications in high-yield pulps such as chemithermomechanical pulp (CTMP). Sulfonation uniformity is essential for the energy-efficient production of high-strength CTMP pulp. However, laboratory methods only measure total sulfur and cannot illustrate its distribution at the fiber level, which can be visualized using $\mu$-XRF. In this work, we present a laboratory $\mu$-XRF system developed at Mid Sweden University and assess its capability to detect light elements in CTMP paper handsheets. A 32 $\times$ 32 point grid scan (1.6-1.6 mm$^2$ field of view, 50 $\mu$m step, 300 s/point) successfully resolved sulfur K$\alpha$ (2.31 keV) and calcium K$\alpha$ (3.69 keV) fluorescence without helium flushing. Comparative measurements at the Elettra synchrotron confirmed consistency of sulfur peak position and spatial distribution, with higher spectral resolution and signal-to-noise ratio. Histogram analysis using Wasserstein distance metrics demonstrated close agreement between datasets despite differing acquisition conditions. These results demonstrate that laboratory XRF can reproducibly detect and map sulfur in CTMP fibers under ambient conditions, providing a practical tool to complement synchrotron studies and supporting the development of energy-efficient, fiber-based packaging materials.

physics.ins-det

Next Generation Multi-element monolithic Germanium detectors for Spectroscopy: First integration at ESRF facility

The XAFS-DET work package of the European LEAPS-INNOV project is developing a high-purity Germanium detectors for synchrotron applications requiring spectroscopic-grade response. The detectors integrate three key features: (1) newly designed monolithic Germanium sensors optimised to mitigate charge-sharing events, (2) an improved cooling and mechanical design structure supported by thermal simulations, and (3) complete electronic chain featuring a low-noise CMOS technology-based preamplifier. enabling high X-ray count rate capability over a broad energy range (5-100 keV). This paper discusses the first integration and characterization of one of the two multi-element Ge detectors at the European Synchrotron Radiation Facility (ESRF). The integration phase included validating high-throughput front-End electronics, integrating them with the Ge sensor, and operating them at liquid nitrogen temperature, in addition to the experimental characterization, which consists of electronics noise study and spectroscopic performance evaluation.

physics.ins-det

Progress in the Development of Multi-Element Monolithic Germanium Detectors in LEAPS-INNOV Project: Insights from Detector Performance Simulation

This study presents a detailed simulation-based analysis of the detection limits of multi-element monolithic Germanium (Ge) detectors to cadmium traces in environmental soil samples. Using the capabilities of the Geant4 Monte Carlo toolkit in combination with the Solid State Detector Package, we evaluated the detection limit variation with the sample-to-detector distances and photon flux. These simulations were conducted to mimic realistic conditions, with a photon flux measured by the SAMBA beamline at the SOLEIL synchrotron facility. Our findings for the detection limit for trace amounts of pollutants in low concentrations like cadmium in the soil provide valuable insights for optimizing experimental setups in environmental monitoring and synchrotron-based applications, where precise detection of trace elements is critical.

physics.ins-det

Monte Carlo Simulation of X-rays Multiple Refractive Scattering from Fine Structure Objects imaged with the DEI Technique

In this work we present a novel 3D Monte Carlo photon transport program for simulation of multiple refractive scattering based on the refractive properties of X-rays in highly scattering media, like lung tissue. Multiple scattering reduces not only the quality of the image, but contains also information on the internal structure of the object. This information can be exploited utilizing image modalities such as Diffraction Enhanced Imaging (DEI). To study the effect of multiple scattering a Monte Carlo program was developed that simulates multiple refractive scattering of X-ray photons on monodisperse PMMA (poly-methyl-methacrylate) microspheres representing alveoli in lung tissue. Eventually, the results of the Monte Carlo program were compared to the measurements taken at the SYRMEP beamline at Elettra (Trieste, Italy) on special phantoms showing a good agreement between both data.

physics.med-ph

On image reconstruction with the two-dimensional interpolating resistive readout structure of the Virtual-Pixel detector

The two-dimensional interpolating readout concept of the Virtual-Pixel detector (ViP detector) goes along with an enormous reduction of electronic channels compared to pure pixel devices. However, the special concept of the readout structure demands for adequate position reconstruction methods. Theoretical considerations reflecting the choice and the combination of linear algorithms with emphasis on correct position reconstruction and spatial resolution are presented. A subsequent two-dimensional coordinate transformation further improves the image response of the system. Measured images show how far the theoretical predictions of the simulations can be verified and to what extent they can be used to improve the position reconstruction.

physics.ins-det

Gas gain and signal length measurements with a triple-GEM at different pressures of Ar-, Kr- and Xe-based gas mixtures

We investigate the gas gain behaviour of a triple-GEM configuration in gas mixtures of argon, krypton and xenon with ten and thirty percent of carbon dioxide at pressures between 1 and 3 bar. Since the signal widths affect the dead time behaviour of the detector we present signal length measurements to evaluate the use of the triple-GEM in time-resolved X-ray imaging.

physics.ins-det

Investigation of the performance of an optimised MicroCAT, a GEM and their combination by simulations and current measurements

A MicroCAT (Micro Compteur A Trous) structure which is used for avalanche charge multiplication in gas filled radiation detectors has been optimised with respect to maximum electron transparency and minimum ion feedback. We report on the charge transfer behaviour and the achievable gas gain of this device. A three-dimensional electron and ion transfer simulation is compared to results derived from electric current measurements. Similarly, we present studies of the charge transfer behaviour of a GEM (Gas Electron Multiplier) by current measurements and simulations. Finally, we investigate the combination of the MicroCAT and the GEM by measurements with respect to the performance at different voltage settings, gas mixtures and gas pressures.

physics.ins-det