SearcharxivSearch

arXiv subjects

R. Herbst

Publications and source records attributed to R. Herbst.

At least 19 recordsLinked to original sources

The SPT-3G+ receiver design

We present the thermo-mechanical design of the cryostat and camera optics for SPT-3G+, a new receiver being developed for the South Pole Telescope (SPT). The receiver consists of 14 detector arrays of 90/150 GHz dichroic polarization-sensitive pixels, totaling 24,080 transition-edge sensor detectors. Each detector array lies at the end of an optics tube, each approximately 240 mm in diameter and 772 mm in length, which are arranged in a hexagonal close-packed configuration to achieve a 4 degree diameter field of view. Each optics tube contains four anti-reflection coated lenses fabricated from different materials (alumina, silicon, and nylon) that are designed to also provide infrared filtering that reduces the radiative loading on the cryogenic stages. The optics and detectors are cooled by a combination of a pulse tube cooler for the 40 K and 4 K stages, and a dilution refrigerator for the 1 K and 100 mK stages. Thermal modeling predicts the heat load to be less than 26 W and 1 W for the 40 K and 4 K stages, respectively. The 1,550 kg cryostat has a 1.1 meter diameter at the vacuum window, which is located near the telescope Gregorian focus, and 1.75 meters in height and length. Fabrication of the cryostat will begin in 2026, with installation on the SPT scheduled for the 2028-29 austral summer, ahead of the 2029 winter observing season.

astro-ph.IM

SPT-3G+: A Cosmic Microwave Background Experiment for the South Pole Telescope

SPT-3G+ is the next survey receiver planned to be installed in early 2029 on the 10-meter South Pole Telescope (SPT). This new receiver will feature 6,020 polarization-sensitive dichroic pixels with transition-edge sensors observing in frequency bands centered at 90 GHz and 150 GHz. The 24,080 detectors in the SPT-3G+ receiver will be cooled to 100 mK by a dilution refrigerator and read out using microwave SQUID multiplexing. The optical design of the receiver enables a 4 degree diameter field of view, which is broken up into 14 individual optics tubes each containing cryogenic alumina, silicon, and nylon lenses. These technology choices will allow the SPT-3G+ receiver to improve on the mapping speed of the currently operating SPT-3G receiver by nearly an order of magnitude. Once deployed, the SPT-3G+ receiver will observe for 6-years an area overlapping with the BICEP survey to achieve a combined (90 GHz and 150 GHz) CMB map depth of 0.5 uK-arcmin. Data from these observations will be used to create unprecedentedly deep CMB lensing maps, discover new galaxy clusters, and detect astrophysical transients. The lensing map produced by SPT-3G+ will be used to remove or "delens" foreground B modes, where large-scale structure gravitationally lenses the CMB and converts E modes into B-mode polarization, with the goal of revealing inflationary B modes. Together with data from the BICEP Array as part of the South Pole Observatory, SPT-3G+ data will be used to constrain the tensor-to-scalar ratio $r$ with a goal of achieving a measurement of $\sigma(r) = 0.001$

astro-ph.CO

Next generation direct RF sampling LLRF control and monitoring system for linear accelerators

The low-level RF (LLRF) systems for linear accelerating structures are typically based on heterodyne architectures. The linear accelerators normally have many RF stations and multiple RF inputs and outputs for each station, so the complexity and size of the LLRF system grows rapidly when scaling up. To meet the design goals of being compact and affordable for future accelerators, or upgrading existing ones, we have developed and characterized the next generation LLRF (NG-LLRF) platform based on the RF system-on-chip (RFSoC) for S-band and C-band accelerating structures. The integrated RF data converters in RFSoC sample and generate the RF signals directly without any analogue mixing circuits, which significantly simplified the architecture compared with the conventional LLRF systems. We have performed high-power tests for the NG-LLRF with the S-band accelerating structure in the Next Linear Collider Test Accelerator (NLCTA) test facility at SLAC National Accelerator Laboratory and a C-band structure prototyped for Cool Cooper Collider (CCC). The NG-LLRF platform demonstrated pulse-to-pulse fluctuation levels considerably better than the requirements of the targeted applications and high precision and flexibility in generating and measuring the RF pulses. In this paper, the characterization results of the platform with different system architectures will be summarized and a selection of high-power test results of the NG-LLRF will be presented and analyzed.

physics.acc-ph

A Compact Low-level RF Control System for Advanced Concept Compact Electron Linear Accelerator

A compact low-level RF (LLRF) control system based on RF system-on-chip (RFSoC) technology has been designed for the Advanced Concept Compact Electron Linear-accelerator (ACCEL) program, which has challenging requirements in both RF performance and size, weight and power consumption (SWaP). The compact LLRF solution employs the direct RF sampling technique of RFSoC, which samples the RF signals directly without any analogue up and down conversion. Compared with the conventional heterodyne based architecture used for LLRF system of linear accelerator (LINAC), the elimination of analogue mixers can significantly reduce the size and weight of the system, especially with LINAC requires a larger number of RF channels. Based on the requirements of ACCEL, a prototype LLRF platform has been developed, and the control schemes have been proposed. The prototype LLRF system demonstrated magnitude and phase fluctuation levels below 1% and 1 degree, on the flat top of a 2 microseconds RF pulse. The LLRF control schemes proposed for ACCEL are implemented with a prototype hardware platform. This paper will introduce the new compact LLRF solution and summarize a selection of experimental test results of the prototype itself and with the accelerating structure cavities designed for ACCEL.

physics.acc-ph

High-Power Test of a C-band Linear Accelerating Structure with an RFSoC-based LLRF System

Normal conducting linear particle accelerators consist of multiple rf stations with accelerating structure cavities. Low-level rf (LLRF) systems are employed to set the phase and amplitude of the field in the accelerating structure, and to compensate the pulse-to-pulse fluctuation of the rf field in the accelerating structures with a feedback loop. The LLRF systems are typically implemented with analogue rf mixers, heterodyne based architectures and discrete data converters. There are multiple rf signals from each of rf station, so the number of rf channels required increases rapidly with multiple rf stations. With many rf channels, the footprint, component cost and system complexity of the LLRF hardware increase significantly. To meet the design goals to be compact and affordable for future accelerators, we have designed the next generation LLRF (NG-LLRF) with higher integration level based on RFSoC technology. The NG-LLRF system samples rf signals directly and performs the rf mixing digitally. The NG-LLRF has been characterized in a loopback mode to evaluate the performance of the system and tested with a standing-wave accelerating structure, a prototype for the Cool Copper Collider (C3) with peak rf power up to 16.45 MW. The loopback test demonstrated amplitude fluctuation below 0.15% and phase fluctuation below 0.15 degree, which are considerably better than the requirements of C3. The rf signals from the different stages of accelerating structure at different power levels are measured by the NG-LLRF, which will be critical references for the control algorithm designs. The NG-LLRF also offers flexibility in waveform modulation, so we have used rf pulses with various modulation schemes which could be useful for controlling some of rf stations in accelerators. In this paper, the high-power test results at different stages of the test setup will be summarized, analyzed and discussed.

physics.acc-ph

Performance Evaluation of an RFSoC Operating in a 1.25 Tesla Magnetic Field

The Belle II experiment at the SuperKEKB collider is preparing for an upgrade after 2027-2028 to handle higher luminosity and increased background rates. A Radio Frequency System-on-Chip (RFSoC) has been identified as a potential candidate for a common front-end upgrade for subsystems requiring high-speed waveform digitization. The RFSoC's ADC and DAC channels were tested across various magnetic field strengths and a few different field orientations. Power consumption and boot memory functionality were also assessed. Results indicate stable operation with negligible performance degradation, suggesting the RFSoC's viability for high-speed digitization tasks in high magnetic field environments.

physics.ins-det

Direct RF Sampling based LLRF Control System for C-band Linear Accelerator

Low Level RF (LLRF) control systems of linear accelerators (LINACs) are typically implemented with heterodyne based architectures, which have complex analog RF mixers for up and down conversion. The Gen 3 Radio Frequency System-on-Chip (RFSoC) device from AMD Xilinx integrates data converters with maximum RF frequency of 6~GHz. This enables direct RF sampling of C-band LLRF signal typically operated at 5.712 GHz without any analogue mixers, which can significantly simplify the system architecture. The data converters sample RF signals in higher order Nyquist zones and then up or down convert digitally by the integrated data path in RFSoC. The closed-loop feedback control firmware implemented in FPGA integrated in RFSoC can process the base-band signal from the ADC data path and calculate the updated phase and amplitude to be up-mixed by the DAC data path. We have developed a C-band LLRF control RFSoC platform with direct RF sampling, which targets Cool Copper Collider (C3) and other C or S band LINAC research and development projects. In this paper, the architecture of the platform will be described. We have optimized the configuration of the data converter and characterized performance of them with RF pulses. The test results for some of the key performance parameters for the LLRF platform with our custom solid-state amplifier, such as phase and amplitude stability, will be discussed in this paper.

physics.acc-ph

Searching for Prompt and Long-Lived Dark Photons in Electro-Produced $e^+e^-$ Pairs with the Heavy Photon Search Experiment at JLab

The Heavy Photon Search experiment (HPS) at the Thomas Jefferson National Accelerator Facility searches for electro-produced dark photons. We report results from the 2016 Engineering Run consisting of 10608/nb of data for both the prompt and displaced vertex searches. A search for a prompt resonance in the $e^+e^-$ invariant mass distribution between 39 and 179 MeV showed no evidence of dark photons above the large QED background, limiting the coupling of ε^2 {\geq} 10^-5, in agreement with previous searches. The search for displaced vertices showed no evidence of excess signal over background in the masses between 60 and 150 MeV, but had insufficient luminosity to limit canonical heavy photon production. This is the first displaced vertex search result published by HPS. HPS has taken high-luminosity data runs in 2019 and 2021 that will explore new dark photon phase space.

hep-ex

Solid State Detectors and Tracking for Snowmass

Tracking detectors are of vital importance for collider-based high energy physics (HEP) experiments. The primary purpose of tracking detectors is the precise reconstruction of charged particle trajectories and the reconstruction of secondary vertices. The performance requirements from the community posed by the future collider experiments require an evolution of tracking systems, necessitating the development of new techniques, materials and technologies in order to fully exploit their physics potential. In this article we summarize the discussions and conclusions of the 2022 Snowmass Instrumentation Frontier subgroup on Solid State and Tracking Detectors (Snowmass IF03).

physics.ins-det

Conceptual Design of the Modular Detector and Readout System for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background Stage 4 (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60 percent of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over a wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4's science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 square meters of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing.

astro-ph.IM

Enabling Capabilities for Infrastructure and Workforce in Electronics and ASICs

The impressive progress in data rate capabilities, pattern recognition, and spatial resolution of current detectors in experimental particle physics has been possible thanks to the availability of sophisticated analog processors combined with complex digital signal processors implemented in custom made front end ASICs. The demands in terms of performance and increasingly smaller feature sizes are significant. In order to meet these instrumentation challenges, we need to educate and retain a skilled work force, as well as aggregate design tools and acquired knowledge. We propose a multifaceted initiative to ensure that these needs are met.

physics.ins-det

The EXO-200 detector, part II: Auxiliary Systems

The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.

physics.ins-det

A Microwave SQUID Multiplexer Optimized for Bolometric Applications

A microwave SQUID multiplexer ($μ$MUX) has been optimized for coupling to large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design in a 1820-channel multiplexer configuration for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4-5 GHz. The median white-noise level is 45 pA/$\sqrt{\textrm{Hz}}$, evaluated at 2 Hz, with a 1/f knee $\leq$ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is $\leq$ 0.3%.

astro-ph.IM

Design and performance of a 35-ton liquid argon time projection chamber as a prototype for future very large detectors

Liquid argon time projection chamber technology is an attractive choice for large neutrino detectors, as it provides a high-resolution active target and it is expected to be scalable to very large masses. Consequently, it has been chosen as the technology for the first module of the DUNE far detector. However, the fiducial mass required for "far detectors" of the next generation of neutrino oscillation experiments far exceeds what has been demonstrated so far. Scaling to this larger mass, as well as the requirement for underground construction places a number of additional constraints on the design. A prototype 35-ton cryostat was built at Fermi National Acccelerator Laboratory to test the functionality of the components foreseen to be used in a very large far detector. The Phase I run, completed in early 2014, demonstrated that liquid argon could be maintained at sufficient purity in a membrane cryostat. A time projection chamber was installed for the Phase II run, which collected data in February and March of 2016. The Phase II run was a test of the modular anode plane assemblies with wrapped wires, cold readout electronics, and integrated photon detection systems. While the details of the design do not match exactly those chosen for the DUNE far detector, the 35-ton TPC prototype is a demonstration of the functionality of the basic components. Measurements are performed using the Phase II data to extract signal and noise characteristics and to align the detector components. A measurement of the electron lifetime is presented, and a novel technique for measuring a track's position based on pulse properties is described.

physics.ins-det

Performance of ePix10K, a high dynamic range, gain auto-ranging pixel detector for FELs

ePix10K is a hybrid pixel detector developed at SLAC for demanding free-electron laser (FEL) applications, providing an ultrahigh dynamic range (245 eV to 88 MeV) through gain auto-ranging. It has three gain modes (high, medium and low) and two auto-ranging modes (high-to-low and medium-to-low). The first ePix10K cameras are built around modules consisting of a sensor flip-chip bonded to 4 ASICs, resulting in 352x384 pixels of 100 $μ$m x 100 $μ$m each. We present results from extensive testing of three ePix10K cameras with FEL beams at LCLS, resulting in a measured noise floor of 245 eV rms, or 67 e$^-$ equivalent noise charge (ENC), and a range of 11000 photons at 8 keV. We demonstrate the linearity of the response in various gain combinations: fixed high, fixed medium, fixed low, auto-ranging high to low, and auto-ranging medium-to-low, while maintaining a low noise (well within the counting statistics), a very low cross-talk, perfect saturation response at fluxes up to 900 times the maximum range, and acquisition rates of up to 480 Hz. Finally, we present examples of high dynamic range x-ray imaging spanning more than 4 orders of magnitude dynamic range (from a single photon to 11000 photons/pixel/pulse at 8 keV). Achieving this high performance with only one auto-ranging switch leads to relatively simple calibration and reconstruction procedures. The low noise levels allow usage with long integration times at non-FEL sources. ePix10K cameras leverage the advantages of hybrid pixel detectors with high production yield and good availability, minimize development complexity through sharing the hardware, software and DAQ development with all other versions of ePix cameras, while providing an upgrade path to 5 kHz, 25 kHz and 100 kHz in three steps over the next few years, matching the LCLS-II requirements.

physics.ins-det

Search for a Dark Photon in Electro-Produced $e^{+}e^{-}$ Pairs with the Heavy Photon Search Experiment at JLab

The Heavy Photon Search experiment took its first data in a 2015 engineering run using a 1.056 GeV, 50 nA electron beam provided by CEBAF at the Thomas Jefferson National Accelerator Facility, searching for an electro-produced dark photon. Using 1.7 days (1170 nb$^{-1}$) of data, a search for a resonance in the $e^{+}e^{-}$ invariant mass distribution between 19 and 81 MeV/c$^2$ showed no evidence of dark photon decays above the large QED background, confirming earlier searches and demonstrating the full functionality of the experiment. Upper limits on the square of the coupling of the dark photon to the Standard Model photon are set at the level of 6$\times10^{-6}$. In addition, a search for displaced dark photon decays did not rule out any territory but resulted in a reliable analysis procedure that will probe hitherto unexplored parameter space with future, higher luminosity runs.

hep-ex

Search for a Dark Photon in Electro-Produced $e^{+}e^{-}$ Pairs with the Heavy Photon Search Experiment at JLab

The Heavy Photon Search experiment took its first data in a 2015 engineering run at the Thomas Jefferson National Accelerator Facility, searching for a prompt, electro-produced dark photon with a mass between 19 and 81 MeV/$c^2$. A search for a resonance in the $e^{+}e^{-}$ invariant mass distribution, using 1.7 days (1170 nb$^{-1}$) of data, showed no evidence of dark photon decays above the large QED background, confirming earlier searches and demonstrating the full functionality of the experiment. Upper limits on the square of the coupling of the dark photon to the Standard Model photon are set at the level of 6$\times10^{-6}$. Future runs with higher luminosity will explore new territory.

hep-ex

THGEM-based detectors for sampling elements in DHCAL: laboratory and beam evaluation

We report on the results of an extensive R&D program aimed at the evaluation of Thick-Gas Electron Multipliers (THGEM) as potential active elements for Digital Hadron Calorimetry (DHCAL). Results are presented on efficiency, pad multiplicity and discharge probability of a 10x10 cm2 prototype detector with 1 cm2 readout pads. The detector is comprised of single- or double-THGEM multipliers coupled to the pad electrode either directly or via a resistive anode. Investigations employing standard discrete electronics and the KPiX readout system have been carried out both under laboratory conditions and with muons and pions at the CERN RD51 test beam. For detectors having a charge-induction gap, it has been shown that even a ~6 mm thick single-THGEM detector reached detection efficiencies above 95%, with pad-hit multiplicity of 1.1-1.2 per event; discharge probabilities were of the order of 1e-6 - 1e-5 sparks/trigger, depending on the detector structure and gain. Preliminary beam tests with a WELL hole-structure, closed by a resistive anode, yielded discharge probabilities of <2e-6 for an efficiency of ~95%. Methods are presented to reduce charge-spread and pad multiplicity with resistive anodes. The new method showed good prospects for further evaluation of very thin THGEM-based detectors as potential active elements for DHCAL, with competitive performances, simplicity and robustness. Further developments are in course.

physics.ins-det