Searcharxiv⌕ Search

arXiv subjects

R. I. P. Sedmik

Publications and source records attributed to R. I. P. Sedmik.

3 recordsLinked to original sources

qBounce: First Measurement of the Neutron Electric Charge with a Ramsey-type GRS Experiment

The qBounce collaboration built over the last years a new Ramsey-type Gravitational Resonance Spectroscopy (GRS) experiment. After commissioning between 2016 and 2018, the setup was able to measure the Ramsey transitions with GRS for the first time. Here we present a search of the hypothetical charge of the neutron as an application of GRS to study nonstandard model interactions. This article will describe the measuring principle and the setup in detail.

hep-ex↗

UGR tests with atomic clocks and atom interferometers

Atomic interference experiments test the universality of the coupling between matter-energy and gravity at different spacetime points, thus being in principle able to probe possible violations of the universality of the gravitational redshift (UGR). In this contribution, we introduce a UGR violation model and then discuss UGR tests performed by atomic clocks and atom interferometers on the same footing. We present a large class of atom-interferometric geometries which are sensitive to violations of UGR.

gr-qc↗

The Casimir pressure between metallic plates out of thermal equilibrium: Proposed test for the relaxation properties of free electrons

We propose a test on the role of relaxation properties of conduction electrons in the Casimir pressure between two parallel metal-coated plates kept at different temperatures. It is shown that for sufficiently thick metallic coatings the Casimir pressure and pressure gradient are determined by the mean of the equilibrium contributions calculated at temperatures of the two plates and by the term independent on separation. Numerical computations of the nonequilibrium pressures are performed for two parallel Au plates of finite thickness as a function of separation and temperature of one of the plates using the plasma and Drude models for extrapolation of the optical data of Au to low frequencies. The obtained results essentially depend on the extrapolation used. Modifications of the CANNEX setup, originally developed to measure the Casimir pressure and pressure gradient in thermal equilibrium, are suggested, which allow different temperatures of one of the plates. Computations of the nonequilibrium pressure and pressure gradient are performed for a realistic experimental configuration. According to our results, even with only a 10~K difference in temperature between the plates, the experiment could discriminate between different theoretical predictions for the total pressure and its gradient, as well as for the contributions to them due to nonequilibrium, at high confidence.

quant-ph↗