SearcharxivSearch

arXiv subjects

R. Ichimiya

Publications and source records attributed to R. Ichimiya.

2 recordsLinked to original sources

Software-based discharge suppressor using an EPICS data acquisition system as a rapid prototype at the LIPAc beam extraction system

Internal continuous discharge can rapidly damage high-current ion sources and their extraction systems composed of several electrodes at high voltage. To prevent this continuous discharge inside the extraction system, a rapid prototype using an Experimental Physics and Industrial Control System (EPICS) software system for data acquisition has been implemented. During commissioning of the 140 mA deuterium electron cyclotron resonance ion source of the Linear IFMIF Prototype Accelerator (LIPAc), discharges were often observed during plasma tuning of the ion source and beam optics tuning of the extraction system. If such continuous discharge can be avoided, discharge-related damage such as melting electrode edges and holes in the boron nitride disk in the ion source can be minimized and thus an efficient machine operation can be achieved. A veto signal is output to the machine protection system, which is then in charge of the RF power shutdown of the ion source for a pre-determined time. The average reaction time of this system has been measured and is about 10 ms from discharge detection to RF power shutdown of the ion source with a 50 Hz sampling frequency. This is hundreds of times slower than hardware-based implementation. However, it prevents almost all continuous discharges at the LIPAc ion source and extraction system, and is still much faster than an operator's reaction time.

physics.acc-ph

Radiation Damage Study for PHENIX Silicon Stripixel Sensors

Silicon stripixel sensors which were developed at BNL will be installed as part of the RHIC-PHENIX silicon vertex tracker (VTX). RHIC II operations provide luminosity up to 2x10^32 /cm2/s so the silicon stripixel sensors will be exposed to a significant amount of radiation. The most problematic radiation effect for VTX is the increase of leakage current, which degrades the signal to noise ratio and may saturate the readout electronics. We studied the radiation damage using the same diodes as CERN-RD48. First, the proportionality between the irradiation fluence and the increase of leakage current of CERN-RD48 was reproduced. Then beam experiments with stripixel sensor were done in which leakage current was found to increase in the same way as that of thereference diode. A stripixel sensor was also irradiated at the PHENIX interaction region (IR) during the 2006 run. We found the same relation between the integrated luminosity and determined fluence from increase of leakage current. The expected fluence is 3-6x10^12 Neq/cm2 (1 MeV neutron equivalent) in RHIC II operations for 10 years. Due to this expected exposure, setting the operating temperature in PHENIX to T< 0 deg. C to suppress leakage current is needed to avoid saturation of preamplifiers.

nucl-ex