SearcharxivSearch

arXiv subjects

R. K. Manchanda

Publications and source records attributed to R. K. Manchanda.

16 recordsLinked to original sources

Improved background model for the Large Area X-ray Proportional Counter (LAXPC) instrument on-board AstroSat

We present an improved background model for the Large Area X-ray Proportional Counter (LAXPC) detectors on-board AstroSat. Because of the large collecting area and high pressure, the LAXPC instrument has a large background count rate, which varies during the orbit. Apart from the variation with latitude and longitude during the orbit there is a prominent quasi-diurnal variation which has not been modelled earlier. Using over 5 years of background observations, we determined the period of the quasi-diurnal variation to be 84495 s and using this period, it is possible to account for the variation and also identify time intervals where the fit is not good. These lead to a significant improvement in the background model. The quasi-diurnal variation can be ascribed to the changes in charged particle flux in the near Earth orbit.

astro-ph.IM

LAXPC instrument onboard AstroSat: Five exciting years of new scientific results specially on X-ray Binaries

With its large effective area at hard X-rays, high time resolution and having co-aligned other instruments, AstroSat/LAXPC was designed to usher in a new era in rapid variability studies and wide spectral band measurements of the X-ray binaries. Over the last five years, the instrument has successfully achieved to a significant extent these Science goals. In the coming years, it is poised to make more important discoveries. This paper highlights the primary achievements of AstroSat/LAXPC in unraveling the behavior of black hole and neutron star systems and discusses the exciting possibility of the instrument's contribution to future science.

astro-ph.HE

Large Area X-ray Proportional Counter (LAXPC) in Orbit Performance : Calibration, background, analysis software

The Large Area X-ray Proportional Counter (LAXPC) instrument on-board AstroSat has three nominally identical detectors for timing and spectral studies in the energy range of 3--80 keV. The performance of these detectors during the five years after the launch of AstroSat is described. Currently, only one of the detector is working nominally. The variation in pressure, energy resolution, gain and background with time are discussed. The capabilities and limitations of the instrument are described. A brief account of available analysis software is also provided.

astro-ph.IM

LAXPC / AstroSat Study of ~ 1 and ~ 2 mHz Quasi-periodic Oscillations in the Be/X-ray Binary 4U 0115+63 During its 2015 Outburst

The Be X-ray Binary 4U 0115+63 was observed by Large Area X-ray Proportional Counter (LAXPC) instrument on AstroSat on 2015 October 24 during the peak of a giant Type II outburst. Prominent intensity oscillations at ~ 1 and ~ 2 mHz frequency were detected during the outburst. Nuclear Spectroscopic Telescope Array (NuSTAR) observations made during the same outburst also show mHz quasi periodic oscillations (QPOs). Details of the oscillations and their characteristics deduced from LAXPC/AstroSat and NuSTAR observations are reported in this paper. Analysis of the archival Rossi X-ray Timing Explorer (RXTE)/Proportional Counter Array (PCA) data during 2001-11 also show presence of mHz QPOs during some of the outbursts and details of these QPOs are also reported. Possible models to explain the origin of the mHz oscillations are examined. Similar QPOs, albeit at higher frequencies, have been reported from other neutron star and black hole sources and both may have a common origin. Current models to explain the instability in the inner accretion disk causing the intense oscillations are discussed.

astro-ph.HE

Effects of thermonuclear X-ray bursts on non-burst emissions in the soft state of 4U 1728--34

It has recently been shown that the persistent emission of a neutron star low-mass X-ray binary (LMXB) evolves during a thermonuclear (type-I) X-ray burst. The reason of this evolution, however, is not securely known. This uncertainty can introduce significant systematics in the neutron star radius measurement using burst spectra, particularly if an unknown but significant fraction of the burst emission, which is reprocessed, contributes to the changes in the persistent emission during the burst. Here, by analyzing individual burst data of AstroSat/LAXPC from the neutron star LMXB 4U 1728--34 in the soft state, we show that the burst emission is not significantly reprocessed by a corona covering the neutron star. Rather, our analysis suggests that the burst emission enhances the accretion disk emission, possibly by increasing the accretion rate via disk. This enhanced disk emission, which is Comptonized by a corona covering the disk, can explain an increased persistent emission observed during the burst. This finding provides an understanding of persistent emission components, and their interaction with the thermonuclear burst emission. Furthermore, since burst photons are not significantly reprocessed, non-burst and burst emissions can be reliably separated, which is required to reduce systematic uncertainties in the stellar radius measurement.

astro-ph.HE

X-ray timing analysis of Cyg X-3 using AstroSat/LAXPC: Detection of milli-hertz quasi-periodic oscillations during the flaring hard X-ray state

We present here results from the X-ray timing and spectral analysis of the X-ray binary Cyg X-3 using observations from Large Area X-ray Proportional Counter (LAXPC) on-board AstroSat. Consecutive lightcurves observed over a period of one year show the binary orbital period of 17253.56 +/- 0.19 sec. Another low-amplitude, slow periodicity of the order of 35.8 +/- 1.4 days is observed which may be due to the orbital precession as suggested earlier by Molteni et al. (1980). During the rising binary phase, power density spectra from different observations during flaring hard X-ray state show quasi-periodic oscillations (QPOs) at ~5-8 mHz, ~12-14 mHz, ~18-24 mHz frequencies at the minimum confidence of 99%. However, during the consecutive binary decay phase, no QPO is detected up to 2-sigma significance. Energy-dependent time-lag spectra show soft lag (soft photons lag hard photons) at the mHz QPO frequency and the fractional rms of the QPO increases with the photon energy. During the binary motion, the observation of mHz QPOs during the rising phase of the flaring hard state may be linked to the increase in the supply of the accreting material in the disk and corona via stellar wind from the companion star. During the decay phase, the compact source moves in the outer wind region causing the decrease in the supply of material for accretion. This may cause weakening of the mHz QPOs below the detection limit. This is also consistent with the preliminary analysis of the orbital phase-resolved energy spectra presented in this paper.

astro-ph.HE

Calibration of the Large Area X-ray Proportional Counter (LAXPC) instrument on-board AstroSat

We present the calibration and background model for the Large Area X-ray Proportional Counter (LAXPC) detectors on-board AstroSat. LAXPC instrument has three nominally identical detectors to achieve large collecting area. These detectors are independent of each other and in the event analysis mode, they record the arrival time and energy of each photon that is detected. The detectors have a time-resolution of 10 $μ$s and a dead-time of about 42 $μ$s. This makes LAXPC ideal for timing studies. The energy resolution and peak channel to energy mapping were obtained from calibration on ground using radioactive sources coupled with GEANT4 simulations of the detectors. The response matrix was further refined from observations of the Crab X-ray source after launch. At around 20 keV the energy resolution of detector is about 10--15\%, while the combined effective area of the 3 detectors is about 6000 cm$^2$.

astro-ph.IM

Large Area X-ray Proportional Counter (LAXPC) Instrument on AstroSat and Some Preliminary Results from its performance in the orbit

Large Area X-ray Propositional Counter (LAXPC) instrument on AstroSat is aimed at providing high time resolution X-ray observations in 3 to 80 keV energy band with moderate energy resolution. To achieve large collecting area, a cluster of three co-aligned identical LAXPC detectors, is used to realize an effective area in access of about 6000 cm2 at 15 keV. The large detection volume of the LAXPC detectors, filled with xenon gas at about 2 atmosphere pressure, results in detection efficiency greater than 50%, above 30 keV. In this article, we present salient features of the LAXPC detectors, their testing and characterization in the laboratory prior to launch and calibration in the orbit. Some preliminary results on timing and spectral characteristics of a few X-ray binaries and other type of sources, are briefly discussed to demonstrate that the LAXPC instrument is performing as planned in the orbit.

astro-ph.IM

Large Area X-ray Proportional Counter (LAXPC) Instrument on AstroSat

Large Area X-ray Proportional Counter (LAXPC) is one of the major AstroSat payloads. LAXPC instrument will provide high time resolution X-ray observations in 3 to 80 keV energy band with moderate energy resolution. A cluster of three co-aligned identical LAXPC detectors is used in AstroSat to provide large collection area of more than 6000 cm2 . The large detection volume (15 cm depth) filled with xenon gas at about 2 atmosphere pressure, results in detection efficiency greater than 50%, above 30 keV. With its broad energy range and fine time resolution (10 microsecond), LAXPC instrument is well suited for timing and spectral studies of a wide variety of known and transient X-ray sources in the sky. We have done extensive calibration of all LAXPC detectors using radioactive sources as well as GEANT4 simulation of LAXPC detectors. We describe in brief some of the results obtained during the payload verification phase along with LXAPC capabilities.

astro-ph.IM

Performance of Large Area X-ray Proportional Counters in a Balloon Experiment

ASTROSAT is India's first satellite fully devoted to astronomical observations covering a wide spectral band from optical to hard X-rays by a complement of 4 co-aligned instruments and a Scanning Sky X-ray Monitor. One of the instruments is Large Area X-ray Proportional Counter with 3 identical detectors. In order to assess the performance of this instrument, a balloon experiment with two prototype Large Area X-ray Proportional Counters (LAXPC) was carried out on 2008 April 14. The design of these LAXPCs was similar to those on the ASTROSAT except that their field of view (FOV) was 3$^{\circ}$ $\times$ 3$^{\circ}$ versus FOV of 1$^{\circ}$ $\times$ 1$^{\circ}$ for the LAXPCs on the ASTROSAT. The LAXPCs are aimed at the timing and spectral studies of X-ray sources in 3-80 keV region. In the balloon experiment, the LAXPC, associated electronics and support systems were mounted on an oriented platform which could be pre-programmed to track any source in the sky. A brief description of the LAXPC design, laboratory tests, calibration and the detector characteristics is presented here. The details of the experiment and background counting rates of the 2 LAXPCs at the float altitude of about 41 km are presented in different energy bands. The bright black hole X-ray binary Cygnus X-1 (Cyg X-1) was observed in the experiment for $\sim$ 3 hours. Details of Cyg X-1 observations, count rates measured from it in different energy intervals and the intensity variations of Cyg X-1 detected during the observations are presented and briefly discussed.

astro-ph.IM

A Multicoloured View of 2S 0114+650

We report the results of radio and X-ray observations of the high mass X-ray binary 2S 0114+650, made with the Giant Meterwave Radio Telescope and the Rossi X-ray Timing Explorer respectively. No emission was detected at radio wavelengths. The neutral hydrogen column density was found to vary over the orbital period, while no variability over the the super-orbital period was observed. We discuss the causes of the observed relationships and the implications for the underlying mechanisms.

astro-ph

Low Frequency Radio Observations of GRS1915+105 with GMRT

We present the first detailed low frequency radio measurements of the galactic microquasar GRS1915+105 with GMRT. Simultaneous observations were carried out at 610 and 244 MHz. Our data does not show any signature of spectral turn over even at low radio frequency of 244 MHz. We propose that while the radio emission at high radio frequencies could predominantly come from compact jets, the emission at lower frequency originates in the lobes at the end of the jet which acts like a reservoir of low energy electrons.

astro-ph

GMRT observations of the field of INTEGRAL X-ray sources- I

The INTEGRAL observatory has discovered a variety of hard X-ray sources in the Galactic plane since its launch. Using GMRT, we have made repeated observations of these sources to search for the radio counterparts of seventeen of them at low frequencies. The source positions were taken from the various ATEL and IAUC reporting their discovery. Possible radio counterparts for seven of these sources namely, IGR J06074+2205, IGR J15479-4529, IGR J16479-4514, IGR J17091-3624, IGR J18027-1455, IGR J18539+0727 and IGR J21247+5058 were detected within 3$σ$ of the position uncertainty derived from the INTEGRAL observations. The offset in the radio position was calculated using the positions mentioned in the ATEL. We have also analyzed the available NVSS images for a few of these fields at 1.4 GHz along with our observations. In this paper we present the radio images and the best fit positions for the positive detections. The X-ray variability for few of the sources within the time scales of 100 s to 1 ks as seen in the RXTE/PCA light curves suggests their Galactic origin and possible binary nature. We discuss briefly the characteristics of these sources from the available information at different wave bands.

astro-ph

Low frequency radio monitoring of Cygnus X-1 and Cygnus X-3

We present results of monitoring observations of the micro-quasars CygnusX-1 and Cygnus X-3 at 0.61 and 1.28 GHz. The observations were performed with Giant Meter-wave Radio Telescope, GMRT, between 2003 June and 2005 January. Variable, unresolved sources were found in both cases. Cyg X-1 was detected in about half of the observations, with a median flux density about 7 mJy at each frequency. The results show clearly that there is a break in the spectrum above 1.28 GHz. The variations in Cyg X-1 may be due to refractive interstellar scintillation. Cyg X-3 was detected in each observation, and varied by a factor of 4. For this source, models of the scintillation suggest a very long timescale (of the order of 40 yr at 1.28 GHz), and therefore we believe that the variations are intrinsic to the source.

astro-ph

A double peaked pulse profile observed in GX 1+4

The hard X-ray pulsar GX 1+4 was observed several times in the last few years with a pair of balloon-borne Xenon filled Multi-cell Proportional Counters (XMPC). In a balloon flight made on 22 March 1995, the source was detected in a bright state, the average observed source count rate being $8.0\pm0.2/s$ per detector. X-ray pulsations with a period of $121.9\pm0.1$ s were detected in the source with a broad double peak pulse feature. When observed in December 1993 with the same instrument, the pulse profile of GX 1+4 showed a single peak. This change in the pulse profile to a double pulse structure in about 15 months indicates either activation of the opposite pole of the neutron star if the magnetic field is asymmetric or possibly a change in the beam pattern, from a pencil beam to a fan beam. Assuming a fan beam configuration, the pulse profile is used to find the inclinations of the magnetic axis and the viewing axis with the spin axis. The derived angles support the GINGA observations of a dip in the pulse profile which was resolved to have a local maximum in one of the observations and was explained with resonance scattering of cyclotron line energy photons by the accretion column (Makishima et al., \markcite{maki1988}, Dotani et al., \markcite{dotani1989}.). Compared to our previous observation of the same source with the same telescope (Rao et al., \markcite{rao1994}) a period change rate of $0.72 \pm 0.40 s/yr$ is obtained which is the lowest rate of change of period for this source since its discovery. Average pulse fraction in the hard X-ray range is low (30%), consistent with its anti correlation with luminosity as reported by us earlier (Rao et al., \markcite{rao1994}) and the observed spectrum is very hard (power law photon index $1.67\pm0.12$).

astro-ph