SearcharxivSearch

arXiv subjects

R. Kauffman

Publications and source records attributed to R. Kauffman.

4 recordsLinked to original sources

Absolute Calibration of a Time-Resolved High Resolution X-ray Spectrometer for the National Ignition Facility (invited)

A high resolution, Diagnostic Instrument Manipulator (DIM)-based x-ray Bragg crystal spectrometer has been calibrated for and deployed at the National Ignition Facility (NIF) to diagnose plasma conditions in ignition capsules near stagnation times. The spectrometer has two conical crystals in the Hall geometry focusing rays from the Kr He$\alpha$, Ly$\alpha$, and He$\beta$ complexes onto a streak camera, with the physics objectives of measuring time-resolved electron density and temperature through observing Stark broadening and the relative intensities of dielectronic satellites. A third von H\'amos crystal that time-integrates the Kr He$\alpha$, He$\beta$ and intervening energy range provides in-situ calibration for the streak camera signals. The spectrometer has been absolutely calibrated using a microfocus x-ray source, an array of CCD and single-photon-counting detectors, and multiple K- and L-absorption edge filters at the Princeton Plasma Physics Laboratory (PPPL) x-ray laboratory. Measurements of the integrated reflectivity, energy range, and energy resolution for each crystal are discussed. These calibration data provide absolute x-ray signal levels for NIF measurements, enabling precise filter selection and comparisons to simulations.

physics.plasm-ph

Hot Spot Evolution Measured by High-Resolution X-Ray Spectroscopy at the National Ignition Facility

Evolution of the hot spot plasma conditions was measured using high-resolution x-ray spectroscopy at the National Ignition Facility (NIF). The capsules were filled with DD gas with trace levels of Kr, and had either a high-density-carbon (HDC) ablator or a tungsten (W)-doped HDC ablator. Time-resolved measurement of the Kr He$\beta$ spectra, absolutely calibrated by a simultaneous time-integrated measurement, allows inference of the electron density and temperature through observing Stark broadening and the relative intensities of dielectronic satellites. By matching the calculated hot spot emission using a collisional-radiative code to experimental observations, the hot spot size and areal density are determined. These advanced spectroscopy techniques further reveal the effect of W dopant in the ablator on the hot spot parameters for their improved implosion performance.

physics.plasm-ph

PRODUCTION OF DRELL--YAN PAIRS IN HIGH ENERGY NUCLEON--NUCLEON COLLISIONS

We compute cross sections for the Drell-Yan process in N--N collisions at next-to-leading order in $α_s$. The mass, rapidity, transverse momentum, and angular dependence of these cross sections are presented. An estimate of higher order corrections is obtained from next-to-next-to-leading order calculation of the mass distribution. We compare the results with some of the existing data to show the quality of the agreement between calculations and data. We present predictions for energies which will become available at the RHIC and LHC colliders. Uncertainties in these predictions due to choices of scale, scheme and parton distribution are discussed.

hep-ph

QCD Corrections to Higgs Boson Production: Non- Leading Terms in the Heavy Quark Limit

We compute analytic results for the QCD corrections to Higgs boson production via gluon fusion in hadronic collisions in the limit in which the top quark is much heavier than the Higgs boson. The first non-leading corrections of $Ø(α_s^3 \mh^2/m_t^2)$ are given and numerical results presented for both LHC and SSC energies. We confirm earlier numerical results showing that the dominant corrections have the same mass dependence as the Born cross section.

hep-ph