Searcharxiv⌕ Search

arXiv subjects

R. Liu

Publications and source records attributed to R. Liu.

At least 37 records · Page 2Linked to original sources

The Lobster Eye Imager for Astronomy Onboard the SATech-01 Satellite

The Lobster Eye Imager for Astronomy (LEIA), a pathfinder of the Wide-field X-ray Telescope of the Einstein Probe (EP) mission, was successfully launched onboard the SATech-01 satellite of the Chinese Academy of Sciences on 27 July 2022. In this paper, we introduce the design and on-ground test results of the LEIA instrument. Using state-of-the-art Micro-Pore Optics (MPO), a wide field-of-view (FoV) of 346 square degrees (18.6 degrees * 18.6 degrees) of the X-ray imager is realized. An optical assembly composed of 36 MPO chips is used to focus incident X-ray photons, and four large-format complementary metal-oxide semiconductor (CMOS) sensors, each of 6 cm * 6 cm, are used as the focal plane detectors. The instrument has an angular resolution of 4 - 8 arcmin (in FWHM) for the central focal spot of the point spread function, and an effective area of 2 - 3 cm2 at 1 keV in essentially all the directions within the field of view. The detection passband is 0.5 - 4 keV in the soft X-rays and the sensitivity is 2 - 3 * 10-11 erg s-1 cm-2 (about 1 mini-Crab) at 1,000 second observation. The total weight of LEIA is 56 kg and the power is 85 W. The satellite, with a design lifetime of 2 years, operates in a Sun-synchronous orbit of 500 km with an orbital period of 95 minutes. LEIA is paving the way for future missions by verifying in flight the technologies of both novel focusing imaging optics and CMOS sensors for X-ray observation, and by optimizing the working setups of the instrumental parameters. In addition, LEIA is able to carry out scientific observations to find new transients and to monitor known sources in the soft X-ray band, albeit limited useful observing time available.

astro-ph.IM↗

Nuclear recoil response of liquid xenon and its impact on solar 8B neutrino and dark matter searches

Knowledge of the ionization and scintillation responses of liquid xenon (LXe) to nuclear recoils is crucial for LXe-based dark matter experiments. Current calibrations carry large uncertainties in the low-energy region below $\sim3$ keV$_nr$ where signals from dark matter particles of $<$10 GeV/c$^2$ masses are expected. The coherent elastic neutrino-nucleus scattering (CE$ν$NS) by solar $^8$B neutrinos also results in a continuum of nuclear recoil events below 3.0 keV$_{nr}$ (99\% of events), which further complicates low-mass dark matter searches in LXe experiments. In this paper, we describe a method to quantify the uncertainties of low-energy LXe responses using published calibration data, followed by case studies to evaluate the impact of yield uncertainties on ${^8}$B searches and low-mass dark matter sensitivity in a typical ton-scale LXe experiment. We conclude that naively omitting yield uncertainties leads to overly optimistic limits by factor $\sim2$ for a 6 GeV/c$^2$ WIMP mass. Future nuclear recoil light yield calibrations could allow experiments to recover this sensitivity and also improve the accuracy of solar ${^8}$B flux measurements.

hep-ex↗

A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of $^{100}$Mo-enriched Li$_2$MoO$_4$ crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70--90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained outstanding energy resolutions at the 356 keV line from a $^{133}$Ba source with one light detector achieving 0.71(5) keV FWHM, which is -- to our knowledge -- the best ever obtained when compared to $γ$ detectors of any technology in this energy range.

physics.ins-det↗

An Energy-dependent Electro-thermal Response Model of CUORE Cryogenic Calorimeter

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay ($0νββ$) in $^{130}\text{Te}$. CUORE uses a cryogenic array of 988 TeO$_2$ calorimeters operated at $\sim$10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. We demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.

physics.ins-det↗

Search for Neutrinoless $β^+EC$ Decay of $^{120}$Te with CUORE

CUORE is a large scale cryogenic experiment searching for neutrinoless double beta decay ($0νββ$) in $^{130}$Te. The CUORE detector is made of natural tellurium, providing the possibility of rare event searches on isotopes other than $^{130}$Te. In this work we describe a search for neutrinoless positron emitting electron capture ($0νβ^+EC$) decay in $^{120}$Te with a total TeO$_2$ exposure of 355.7 kg $\cdot$ yr, corresponding to 0.2405 kg $\cdot$ yr of $^{120}$Te. Albeit $0 νββ$ with two final state electrons represents the most promising channel, the emission of a positron and two 511-keV $γ$s make $0νβ^+EC$ decay signature extremely clear. To fully exploit the potential offered by the detector modularity we include events with different topology and perform a simultaneous fit of five selected signal signatures. Using blinded data we extract a median exclusion sensitivity of $3.4 \cdot 10^{22}$ yr at 90% Credibility Interval (C.I.). After unblinding we find no evidence of $0νβ^+EC$ signal and set a 90% C.I. Bayesian lower limit of $2.9 \cdot 10^{22}$ yr on $^{120}$Te half-life. This result improves by an order of magnitude the existing limit from the combined analysis of CUORE-0 and Cuoricino.

nucl-ex↗

Search for Majorana neutrinos exploiting millikelvin cryogenics with CUORE

The possibility that neutrinos may be their own antiparticles, unique among the known fundamental particles, arises from the symmetric theory of fermions proposed by Ettore Majorana in 1937. Given the profound consequences of such Majorana neutrinos, among which is a potential explanation for the matter-antimatter asymmetry of the universe via leptogenesis, the Majorana nature of neutrinos commands intense experimental scrutiny globally; one of the primary experimental probes is neutrinoless double beta ($0 νββ$) decay. Here we show results from the search for $0 νββ$ decay of $^{130}$Te, using the latest advanced cryogenic calorimeters with the CUORE experiment. CUORE, operating just 10 millikelvin above absolute zero, has pushed the state of the art on three frontiers: the sheer mass held at such ultra-low temperatures, operational longevity, and the low levels of ionising radiation emanating from the cryogenic infrastructure. We find no evidence for $0 νββ$ decay and set a lower bound of $T_{1/2}^{0 ν} > 2.2 \times 10^{25}$ years at a 90% credibility interval. We discuss potential applications of the advances made with CUORE to other fields such as direct dark matter, neutrino and nuclear physics searches and large-scale quantum computing, which can benefit from sustained operation of large payloads in a low-radioactivity, ultra-low temperature cryogenic environment.

nucl-ex↗

Toward CUPID-1T

Current experiments to search for broken lepton-number symmetry through the observation of neutrinoless double-beta decay ($0\mathrm{νββ}$) provide the most stringent limits on the Majorana nature of neutrinos and the effective Majorana neutrino mass ($m_{ββ}$). The next-generation experiments will focus on the sensitivity to the $0\mathrm{νββ}$ half-life of $\mathcal{O}(10^{27}$--$10^{28}$~years$)$ and $m_{ββ}\lesssim15$~meV, which would provide complete coverage of the so-called Inverted Ordering region of the neutrino mass parameter space. By taking advantage of recent technological breakthroughs, new, future calorimetric experiments at the 1-ton scale can increase the sensitivity by at least another order of magnitude, exploring the large fraction of the parameter space that corresponds to the Normal neutrino mass ordering. In case of a discovery, such experiments could provide important insights toward a new understanding of the mechanism of $0\mathrm{νββ}$. We present here a series of projects underway that will provide advancements in background reduction, cryogenic readout, and physics searches beyond $0\mathrm{νββ}$, all moving toward the next-to-next generation CUPID-1T detector.

nucl-ex↗

Optimization of the first CUPID detector module

CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the simultaneous heat and light detection allows us to reject the dominant background of $α$ particles, as proven by the CUPID-0 and CUPID-Mo demonstrators. In this work we present the results of the first test of the CUPID baseline module. In particular, we propose a new optimized detector structure and light sensors design to enhance the engineering and the light collection, respectively. We characterized the heat detectors, achieving an energy resolution of (5.9 $\pm$ 0.2) keV FWHM at the $Q$-value of $^{100}$Mo (about 3034 keV). We studied the light collection of the baseline CUPID design with respect to an alternative configuration which features gravity-assisted light detectors' mounting. In both cases we obtained an improvement in the light collection with respect to past measures and we validated the particle identification capability of the detector, which ensures an $α$ particle rejection higher than 99.9%, fully satisfying the requirements for CUPID.

physics.ins-det↗

Joint Waveform and Filter Designs for STAP-SLP-based MIMO-DFRC Systems

Dual-function radar-communication (DFRC), which can simultaneously perform both radar and communication functionalities using the same hardware platform, spectral resource and transmit waveform, is a promising technique for realizing integrated sensing and communication (ISAC). Spacetime adaptive processing (STAP) in multi-antenna radar systems is the primary tool for detecting moving targets in the presence of strong clutter. The idea of joint spatial-temporal optimization in STAP-based radar systems is consistent with the concept of symbol-level precoding (SLP) for multi-input multi-output (MIMO) communications, which optimizes the transmit waveform for each of the transmitted symbols. In this paper, we combine STAP and SLP and propose a novel STAP-SLP-based DFRC system that enjoys the advantages of both techniques. The radar output signal-to-interference-plus-noise ratio (SINR) is maximized by jointly optimizing the transmit waveform and receive filter, while satisfying the communication quality-of-service (QoS) constraint and various waveform constraints including constant-modulus, similarity and peak-to-average power ratio (PAPR). An efficient algorithm framework based on majorization-minimization (MM) and nonlinear equality constrained alternative direction method of multipliers (neADMM) methods is proposed to solve these complicated non-convex optimization problems. Simulation results verify the effectiveness of the proposed STAP-SLP-based MIMO-DRFC scheme and the associate algorithms.

eess.SP↗

Revealing a charge-density-wave gap in the predicted weak topological insulator HoSbTe

HoSbTe was predicted to be a weak topological insulator, whose spin-orbit coupling (SOC) gaps are reported to be as large as hundreds of meV. Utilizing infrared spectroscopy, we find that the compound is of metallic nature from 350 K down to 10 K. Particularly, both of its itinerant carrier density and scattering rate are demonstrated to decrease with temperature cooling, which is responsible for the appearance of a broad hump feature in the temperature dependent resistivity around 200 K. More importantly, we reveal the appearance of a charge density wave (CDW) gap in addition to the SOC related gap. The energy scale of the CDW gap is identified to be 364 meV at 10 K, which shift to 252 meV at 350 K. The coexistence of CDW and SOC gaps in the same compound paves a new avenue to explore more intriguing physics.

cond-mat.str-el↗

Joint Symbol-Level Precoding and Reflecting Designs for IRS-Enhanced MU-MISO Systems

Intelligent reflecting surfaces (IRSs) have emerged as a revolutionary solution to enhance wireless communications by changing propagation environment in a cost-effective and hardware-efficient fashion. In addition, symbol-level precoding (SLP) has attracted considerable attention recently due to its advantages in converting multiuser interference (MUI) into useful signal energy. Therefore, it is of interest to investigate the employment of IRS in symbol-level precoding systems to exploit MUI in a more effective way by manipulating the multiuser channels. In this paper, we focus on joint symbol-level precoding and reflecting designs in IRS-enhanced multiuser multiple-input single-output (MU-MISO) systems. Both power minimization and quality-of-service (QoS) balancing problems are considered. In order to solve the joint optimization problems, we develop an efficient iterative algorithm to decompose them into separate symbol-level precoding and block-level reflecting design problems. An efficient gradient-projection-based algorithm is utilized to design the symbol-level precoding and a Riemannian conjugate gradient (RCG)-based algorithm is employed to solve the reflecting design problem. Simulation results demonstrate the significant performance improvement introduced by the IRS and illustrate the effectiveness of our proposed algorithms.

eess.SP↗

Simulations of Events for the LUX-ZEPLIN (LZ) Dark Matter Experiment

The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1--2)$\times10^{-12}$\,pb at a WIMP mass of 40 GeV/$c^2$. This paper describes the simulations framework that, along with radioactivity measurements, was used to support this projection, and also to provide mock data for validating reconstruction and analysis software. Of particular note are the event generators, which allow us to model the background radiation, and the detector response physics used in the production of raw signals, which can be converted into digitized waveforms similar to data from the operational detector. Inclusion of the detector response allows us to process simulated data using the same analysis routines as developed to process the experimental data.

physics.ins-det↗

Projected sensitivity of the LUX-ZEPLIN experiment to the $0νββ$ decay of $^{136}$Xe

The LUX-ZEPLIN (LZ) experiment will enable a neutrinoless double beta decay search in parallel to the main science goal of discovering dark matter particle interactions. We report the expected LZ sensitivity to $^{136}$Xe neutrinoless double beta decay, taking advantage of the significant ($>$600 kg) $^{136}$Xe mass contained within the active volume of LZ without isotopic enrichment. After 1000 live-days, the median exclusion sensitivity to the half-life of $^{136}$Xe is projected to be 1.06$\times$10$^{26}$ years (90% confidence level), similar to existing constraints. We also report the expected sensitivity of a possible subsequent dedicated exposure using 90% enrichment with $^{136}$Xe at 1.06$\times$10$^{27}$ years.

nucl-ex↗

Measurement of the Gamma Ray Background in the Davis Cavern at the Sanford Underground Research Facility

Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from $γ$-rays emitted by $^{40}$K and the $^{238}$U and $^{232}$Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located within the Davis campus at the Sanford Underground Research Facility, Lead, South Dakota, at the 4,850-foot level. In order to characterise the cavern background, in-situ $γ$-ray measurements were taken with a sodium iodide detector in various locations and with lead shielding. The integral count rates (0--3300~keV) varied from 596~Hz to 1355~Hz for unshielded measurements, corresponding to a total flux in the cavern of $1.9\pm0.4$~$γ~$cm$^{-2}$s$^{-1}$. The resulting activity in the walls of the cavern can be characterised as $220\pm60$~Bq/kg of $^{40}$K, $29\pm15$~Bq/kg of $^{238}$U, and $13\pm3$~Bq/kg of $^{232}$Th.

physics.ins-det↗

T0 Fan-out for Back-n White Neutron Facility at CSNS

the main physics goal for Back-n white neutron facility at China Spallation Neutron Source (CSNS) is to measure nuclear data. The energy of neutrons is one of the most important parameters for measuring nuclear data. Method of time of flight (TOF) is used to obtain the energy of neutrons. The time when proton bunches hit the thick tungsten target is considered as the start point of TOF. T0 signal, generated from the CSNS accelerator, represents this start time. Besides, the T0 signal is also used as the gate control signal that triggers the readout electronics. Obviously, the timing precision of T0 directly affects the measurement precision of TOF and controls the running or readout electronics. In this paper, the T0 fan-out for Back-n white neutron facility at CSNS is proposed. The T0 signal travelling from the CSNS accelerator is fanned out to the two underground experiment stations respectively over long cables. To guarantee the timing precision, T0 signal is conditioned with good signal edge. Furthermore, techniques of signal pre-emphasizing and equalizing are used to improve signal quality after T0 being transmitted over long cables with about 100 m length. Experiments show that the T0 fan-out works well, the T0 signal transmitted over 100 m remains a good time resolution with a standard deviation of 25 ps. It absolutely meets the required accuracy of the measurement of TOF.

physics.ins-det↗

Electronics of Time-of-flight Measurement for Back-n at CSNS

Back-n is a white neutron experimental facility at China Spallation Neutron Source (CSNS). The time structure of the primary proton beam make it fully applicable to use TOF (time-of-flight) method for neutron energy measuring. We implement the electronics of TOF measurement on the general-purpose readout electronics designed for all of the seven detectors in Back-n. The electronics is based on PXIe (Peripheral Component Interconnect Express eXtensions for Instrumentation) platform, which is composed of FDM (Field Digitizer Modules), TCM (Trigger and Clock Module), and SCM (Signal Conditioning Module). T0 signal synchronous to the CSNS accelerator represents the neutron emission from the target. It is the start of time stamp. The trigger and clock module (TCM) receives, synchronizes and distributes the T0 signal to each FDM based on the PXIe backplane bus. Meantime, detector signals after being conditioned are fed into FDMs for waveform digitizing. First sample point of the signal is the stop of time stamp. According to the start, stop time stamp and the time of signal over threshold, the total TOF can be obtained. FPGA-based (Field Programmable Gate Array) TDC is implemented on TCM to accurately acquire the time interval between the asynchronous T0 signal and the global synchronous clock phase. There is also an FPGA-based TDC on FDM to accurately acquire the time interval between T0 arriving at FDM and the first sample point of the detector signal, the over threshold time of signal is obtained offline. This method for TOF measurement is efficient and not needed for additional modules. Test result shows the accuracy of TOF is sub-nanosecond and can meet the requirement for Back-n at CSNS.

physics.ins-det↗

Optical and electronic properties of sub-surface conducting layers in diamond created by MeV B-implantation at elevated temperatures

Boron implantation with in-situ dynamic annealing is used to produce highly conductive sub-surface layers in type IIa (100) diamond plates for the search of a superconducting phase transition. Here we demonstrate that high-fluence MeV ion-implantation, at elevated temperatures avoids graphitization and can be used to achieve doping densities of 6 at.%. In order to quantify the diamond crystal damage associated with implantation Raman spectroscopy was performed, demonstrating high temperature annealing recovers the lattice. Additionally, low-temperature electronic transport measurements show evidence of charge carrier densities close to the metal-insulator-transition. After electronic characterization, secondary ion mass spectrometry was performed to map out the ion profile of the implanted plates. The analysis shows close agreement with the simulated ion-profile assuming scaling factors that take into account an average change in diamond density due to device fabrication. Finally, the data show that boron diffusion is negligible during the high temperature annealing process.

cond-mat.mtrl-sci↗

A summary of the Planck constant measurements using a watt balance with a superconducting solenoid at NIST

Researchers at the National Institute of Standards and Technology have been using a watt balance, NIST-3, to measure the Planck constant $h$ for over ten years. Two recently published values disagree by more than one standard uncertainty. The motivation for the present manuscript is twofold. First, we correct the latest published number to take into account a recently discovered systematic error in mass dissemination at the Bureau International des Poids et Mesures (BIPM). Second, we provide guidance on how to combine the two numbers into one final result. In order to adequately reflect the discrepancy, we added an additional systematic uncertainty to the published uncertainty budgets. The final value of $h$ measured with NIST-3 is $h = 6.626\,069\,36(37)\times 10^{-34}\,\mbox{J\,s}$. This result is $77(57) \times 10^{-9}$ fractionally higher than $h_{\mathrm{90}}$. Each number in parentheses gives the value of the standard uncertainty in the last two digits of the respective value and $h_{\mathrm{90}}$ is the conventional value of the Planck constant given by $h_{\mathrm{90}}\equiv 4 /( K_{\mathrm{J-90}}^2 R_{\mathrm{K-90}})$, where $K_{\mathrm{J-90}}$ and $R_{\mathrm{K-90}}$ denote the conventional values of the Josephson and von Klitzing constants, respectively.

physics.ins-det↗