Initial radiometric calibration of the High-Resolution EUV Imager ($\textrm{HRI}_\textrm{EUV}$) of the Extreme Ultraviolet Imager (EUI) instrument onboard Solar Orbiter

The $\textrm{HRI}_\textrm{EUV}$ telescope was calibrated on ground at the Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, using the Metrology Light Source (MLS) synchrotron in April 2017 during the calibration campaign of the Extreme Ultraviolet Imager (EUI) instrument onboard the Solar Orbiter mission. We use the pre-flight end-to-end calibration and component-level (mirror multilayer coatings, filters, detector) characterization results to establish the beginning-of-life performance of the $\textrm{HRI}_\textrm{EUV}$ telescope which shall serve as a reference for radiometric analysis and monitoring of the telescope in-flight degradation. Calibration activities at component level and end-to-end calibration of the instrument were performed at PTB/MLS synchrotron light source (Berlin, Germany) and the SOLEIL synchrotron. Each component optical property is measured and compared to its semi-empirical model. This pre-flight characterization is used to estimate the parameters of the semi-empirical models. The end-to-end response is measured and validated by comparison with calibration measurements, as well as with its main design performance requirements. The telescope spectral response semi-empirical model is validated by the pre-flight end-to-end ground calibration of the instrument. It is found that $\textrm{HRI}_\textrm{EUV}$ is a highly efficient solar EUV telescope with a peak efficiency superior to 1 e$^-$.ph$^{-1}$), low detector noise ($\approx$ 3 e- rms), low dark current at operating temperature, and a pixel saturation above 120 ke- in low-gain or combined image mode. The ground calibration also confirms a well-modeled spectral selectivity and rejection, and low stray light. The EUI instrument achieves state-of-the-art performance in terms of signal-to-noise and image spatial resolution.

astro-ph.SR

Diffraction limited optics for single atom manipulation

We present an optical system designed to capture and observe a single neutral atom in an optical dipole trap, created by focussing a laser beam using a large numerical aperture N.A.=0.5 aspheric lens. We experimentally evaluate the performance of the optical system and show that it is diffraction limited over a broad spectral range (~ 200 nm) with a large transverse field (+/- 25 microns). The optical tweezer created at the focal point of the lens is able to trap single atoms of 87Rb and to detect them individually with a large collection efficiency. We measure the oscillation frequency of the atom in the dipole trap, and use this value as an independent determination of the waist of the optical tweezer. Finally, we produce with the same lens two dipole traps separated by 2.2 microns and show that the imaging system can resolve the two atoms.

quant-ph