Searcharxiv⌕ Search

arXiv subjects

R. Michael Verkouteren

Publications and source records attributed to R. Michael Verkouteren.

2 recordsLinked to original sources

Primary activity measurement of an Am-241 solution using microgram inkjet gravimetry and decay energy spectrometry

We demonstrate a method for radionuclide assay that is spectroscopic with 100 % counting efficiency for alpha decay. Advancing both cryogenic decay energy spectrometry (DES) and drop-on-demand inkjet metrology, a solution of Am-241 was assayed for massic activity (of order 100 kBq/g) with a relative combined standard uncertainty less than 1 %. We implement live-timed counting, spectroscopic analysis, validation by liquid scintillation (LS) counting, and confirmation of quantitative solution transfer. Experimental DES spectra are well modeled with a Monte Carlo simulation. The model was further used to simulate Pu-238 and Pu-240 impurities, calculate detection limits, and demonstrate the potential for tracer-free multi-nuclide analysis, which will be valuable for new cancer therapeutics based on decay chains, Standard Reference Materials (SRMs) containing impurities, and more widely in nuclear energy, environmental monitoring, security, and forensics.

physics.ins-det↗

Sub-picoliter Traceability of Microdroplet Gravimetry and Microscopy

Gravimetry typically lacks the resolution to measure single microdroplets, whereas microscopy is often inaccurate beyond the resolution limit. To address these issues, we advance and integrate these complementary methods, introducing simultaneous measurements of the same microdroplets, comprehensive calibrations that are independently traceable to the International System of Units (SI), and Monte-Carlo evaluations of volumetric uncertainty. We achieve sub-picoliter agreement of measurements of microdroplets in flight with volumes of approximately 70 pL, with ensemble gravimetry and optical microscopy both yielding 95% coverage intervals of +/- 0.6 pL, or relative uncertainties of +/- 0.9%, and root-mean-square deviations of mean values between the two methods of 0.2 pL or 0.3%. These uncertainties match previous gravimetry results and improve upon previous microscopy results by an order of magnitude. Gravimetry precision depends on the continuity of droplet formation, whereas microscopy accuracy requires that optical diffraction from an edge reference matches that from a microdroplet. Applying our microscopy method, we jet and image water microdroplets suspending fluorescent nanoplastics, count nanoplastic particles after deposition and evaporation, and transfer volumetric traceability to number concentration. We expect that our methods will impact diverse fields involving dimensional metrology and volumetric analysis of microdroplets, including inkjet microfabrication, disease transmission, and industrial sprays.

physics.app-ph↗