Searcharxiv⌕ Search

arXiv subjects

R. Mitteau

Publications and source records attributed to R. Mitteau.

4 recordsLinked to original sources

WEST advanced wall protection achievements toward long pulse operation

Long pulse operation in magnetic fusion devices requires well controlled plasma power exhaust to the divertor \& wall, and avoidance of wall hot spots that could evolve in wall damage. At WEST, 10 major plasma facing components are monitored using 10 series of temperature/power indicators, based on multiple diagnostic systems, among which the infrared viewing system is especially relevant. These indicators span from the most basic ones (temperatures, power and energy from deterministic models) to advanced processes using artificial intelligence acquired through machine learning. Some advanced processes do operate in real time, and feedback on power actuators through the plasma control system, providing active control toward remaining within the safe operational domain. Other advanced processes intervene as forensic tools post discharge to identify possible dangerous situations regarding the power loading to the wall, so that the discharge run plan is adjusted to avoid running into aggravating wall events. No critical wall power event happened during the campaigns C9 to C11 (2024-2025), totalling about 13h of plasma, that would have affected the campaign plan. While it cannot be demonstrated that the active \& intelligent wall protection enabled the new plasma duration record of 1337 seconds, the wall protection system as a whole plausibly contributed to obtaining these record durations by preventing wall hot spots to become critical during the campaigns.

physics.plasm-ph↗

Heat flux deposition on plasma-facing components using a convective model with ripple and Shafranov shift

A heat flux deposition code is a very useful tool for the design of plasma-facing components. The classical cosine model representative of the convective parallel heat flux was coded within the standard finite element code of the CEA Castem 2000. Two perturbations to the idealised magnetic surfaces were taken into account: the Shafranov shift and the ripple of the toroidal magnetic field. The calculation scheme -- named Tokaflu -- was confronted to previous computations on bottom modular limiters and to experiments on the inner first wall. The code was used to optimise the shape of future plasma-facing components in Tore Supra designed for the CIEL project, namely the toroidal pumped limiter and its neutralisers. Developments are under way to include the shadowing of the components, other power deposition schemes and possibly later plasma sections other than circular.

physics.plasm-ph↗

Non destructive testing of actively cooled plasma facing components by means of thermal transient excitation and infrared imaging

SATIR is a new test-bed installed at Tore Supra to perform non destructive examination of actively cooled plasma facing components. Hot and cold water flow successively in the cooling tube of the component and the surface temperature is recorded with an infrared camera. Defects are detected by a slower temperature response above unbrazed areas. The connection between temperature differences and defect sizes is the main difficulty. It is established by tests of standard defects and thermal transient calculations of defective geometries. SATIR has been in use for two years and has proved to be very valuable to test industrial components as well as prototypes.

physics.plasm-ph↗

A geometrical approach to evaluating the heat flux peaking factor on first wall components

In magnetic fusion experiments, a simple technique to evaluate the heat flux on first wall components is a key to controlled plasma surface interaction. The heat flux can be characterized by the peaking factor which is the ratio of the peak heat flux to the average heat flux. The peaking factor can be calculated exactly using simple derivations and standard software tools. This analysis is applied to an Iter class experiment for plasma wall contact during start up phases at 15 MW, in idealised, realistic and misaligned situations. Even though the peaking factors are usually above 10, the peak heat load on the wall remains moderate at a few MW/m${}^2$.

physics.plasm-ph↗