Searcharxiv⌕ Search

arXiv subjects

R. N. Hampp

Publications and source records attributed to R. N. Hampp.

2 recordsLinked to original sources

The Skin Detector System of the LZ Dark Matter Experiment

This paper presents the design, calibration, and performance of the Skin Detector component of the LUX-ZEPLIN (LZ) dark matter experiment. The Skin Detector consists of approximately 2 tonnes of liquid xenon instrumented with 131 photomultiplier tubes, surrounding the central time-projection chamber and functions as an active veto system for background rejection. Energy calibration with monoenergetic gamma sources established a position-dependent energy scale and determined prompt and delayed veto thresholds. Radon decays in the Skin can be identified with less than 15~mm spatial resolution, revealing stable convective flow patterns with measured velocities ranging from 2-4 mm/s that persisted throughout extended data-taking periods. The achieved Skin veto threshold meets or exceeds the design goal of 100~keV throughout the Skin volume. The prompt veto efficiency for gamma rays emitted following electron capture in $^{127}$Xe is found to be ($88 \pm 2$)\%, consistent with the simulated value of ($90.4 \pm 0.6$)\%. M-shell EC decays are used to validate the LZ detector sensitivity for low-mass dark matter during the first science run.

physics.ins-det↗

Search for dark matter particle interactions in an extended nuclear recoil energy window with the LUX-ZEPLIN (LZ) experiment

We report on a search for dark matter particles interacting with xenon nuclei in an exposure of 2.84 tonne-years with the LUX-ZEPLIN (LZ) experiment. An extended nuclear recoil energy window up to approximately 270 keV enables searches for effective field theory and inelastic models of dark matter where high-energy recoils account for a larger fraction of the predicted recoil spectrum compared to the nominal spin independent interaction. We observe one event with characteristics consistent with a nuclear recoil of $248\pm23\,\mathrm{(stat)}\pm23\,\mathrm{(sys)}$ keV, in a region where the known background expectation is low. A profile likelihood ratio test finds tension with the background-only hypothesis at a global significance of 2.6$σ$ when accounting for look-elsewhere effects, with a maximum local significance of 3.4$σ$ across the models tested. We describe the analysis and event of interest, the background model used in the statistical inference, and detail several of the rare background topologies considered.

hep-ex↗