3 recordsLinked to original sources

Evaluation of spatiotemporal tungsten density profiles using Unresolved Transition Arrays in the Large Helical Device

Tungsten spectroscopic studies have been conducted in the Large Helical Device with a pellet injection technique. Spatiotemporal profiles of tungsten density were evaluated using a space-resolved spectrometer, for plasmas with an electron temperature of below 1 keV and electron density of $10^{19}-10^{20}$ $m^{-3}$. Slice & Stack, a method for reconstructing emissivity, was applied to a line at 191.7 {\AA} , which is a part of the Unresolved Transition Array (UTA) spectrum at 90-250 {\AA}. Tungsten density was obtained using photon emission coefficients of $\mathrm{W}^{17+} - \mathrm{W}^{27+}$, evaluated from collisional-radiative model. The tungsten pellet injected from outside the plasma was first ablated in the edge plasma and subsequently diffused throughout the plasma. This behavior is typical of pellet injection experiments. Furthermore, after an event triggered by NBI breakdown, tungsten accumulated in the core plasma. The radiation power was estimated from the evaluated tungsten density profile and cooling factor dataset, and compared with bolometer measurement. This sequence of processes would be useful for validating atomic data of tungsten ions in low-to-intermediate charge states.

physics.plasm-ph

Development of Two-Dimensional Neutron Imager with a Sandwich Configuration

We have developed a two-dimensional neutron imager based on a semiconductor pixelated sensor, especially designed for experiments measuring of a spatial and a temporal behavior of quantum bound states of ultra-cold neutrons. Through these measurements, we expect to measure the ratio between the inertial and gravitational masses of neutrons and to test the equivalence principle in the quantum regime. As one of the principal neutron imagers, we fabricated a sensor with a sandwich configuration, named 10B-INTPIX4-sw, and tested its response to ultra-cold neutrons at the Los Alamos Neutron Science Center (LANSCE). We observed simultaneous events on both sandwiching sensors without significant loss of detection efficiency. The efficiency was evaluated to be about 16%, relative to the 10B/ZnS reference detector. The coincidence condition reduces its efficiency by a factor of about 3.

physics.ins-det

INTPIX4NA -- new integration-type silicon-on-insulator pixel detector for imaging application

INTPIX4NA is an integration-type silicon-on-insulator pixel detector. This detector has a 14.1 x 8.7 mm^2 sensitive area, 425,984 (832 column x 512 row matrix) pixels and the pixel size is 17 x 17 um^2. This detector was developed for residual stress measurement using X-rays (the cos alpha method). The performance of INTPIX4NA was tested with the synchrotron beamlines of the Photon Factory (KEK), and the following results were obtained. The modulation transfer function, the index of the spatial resolution, was more than 50% at the Nyquist frequency (29.4 cycle/mm). The energy resolution analyzed from the collected charge counts is 35.3%--46.2% at 5.415 keV, 21.7%--35.6% at 8 keV, and 15.7%--19.4% at 12 keV. The X-ray signal can be separated from the noise even at a low energy of 5.415 keV at room temperature (approximately 25--27 degree Celsius). The maximum frame rate at which the signal quality can be maintained is 153 fps in the current measurement system. These results satisfy the required performance in the air and at room temperature (approximately 25--27 degree Celsius) condition that is assumed for the environment of the residual stress measurement.