SearcharxivSearch

arXiv subjects

R. Ohta

Publications and source records attributed to R. Ohta.

11 recordsLinked to original sources

Limit cycles and bifurcations in a nonlinear MEMS oscillator with a 1:3 internal resonance. Part I: The case of a driven resonator

This work investigates the behavior of an AlGaAs/GaAs piezoelectric nonlinear MEMS oscillator exhibiting a 1:3 internal resonance. The device is explored in an open-loop configuration, i.e. as a driven resonator, where depending on the drive conditions we observe energy transfer between the first and third modes, and the emergence of supercritical Hopf limit cycles. We examine the dependence of these bifurcations on the oscillator's frequency and amplitude, and reproduce the observed behavior using a system of nonlinearly coupled equations which show interesting scaling behavior.

cond-mat.mes-hall

On-site Background Measurements for the J-PARC E56 Experiment: A Search for Sterile Neutrino at J-PARC MLF

The J-PARC E56 experiment aims to search for sterile neutrinos at the J-PARC Materials and Life Science Experimental Facility (MLF). In order to examine the feasibility of the experiment, we measured the background rates of different detector candidate sites, which are located at the third floor of the MLF, using a detector consisting of plastic scintillators with a fiducial mass of 500 kg. The result of the measurements is described in this article. The gammas and neutrons induced by the beam as well as the backgrounds from the cosmic rays were measured.

physics.ins-det

Status Report (BKG measurement): A Search for Sterile Neutrino at J-PARC MLF

At the 17th J-PARC PAC, which was held on September 2013, we proposed the sterile neutrino search at J-PARC MLF. After reviewing the proposal, PAC recommended to have a background measurement at the detector's candidate site location in their report to investigate whether the background rates can be manageable for the real experiment or not. Therefore, we have performed the background measurements (MLF; 2013BU1301 test experiment) during the summer of 2014, also following the 18th J-PARC PAC recommendations, and the measurements results are described here.

physics.ins-det

Ultralow mode-volume photonic crystal nanobeam cavities for high efficiency coupling to individual carbon nanotube emitters

We report on high efficency coupling of individual air-suspended carbon nanotubes to silicon photonic crystal nanobeam cavities. Photoluminescence images of dielectric- and air-mode cavities reflect their distinctly different mode profiles and show that fields in the air are important for coupling. We find that the air-mode cavities couple more efficiently, and estimated spontaneous emission coupling factors reach a value as high as 0.85. Our results demonstrate advantages of ultralow mode-volumes in air-mode cavities for coupling to low-dimensional nanoscale emitters.

cond-mat.mes-hall

Proposal: A Search for Sterile Neutrino at J-PARC Materials and Life Science Experimental Facility

We propose a definite search for sterile neutrinos at the J-PARC Materials and Life Science Experimental Facility (MLF). With the 3 GeV Rapid Cycling Synchrotron (RCS) and spallation neutron target, an intense neutrino beam from muon decay at rest (DAR) is available. Neutrinos come from μ+ decay, and the oscillation to be searched for is (anti νμ-> anti νe) which is detected by the inverse βdecay interaction (anti νe + p -> e+ + n), followed by a gamma from neutron capture. The unique features of the proposed experiment, compared with the LSND and experiments using horn focused beams, are; (1) The pulsed beam with about 600 ns spill width from J-PARC RCS and muon long lifetime allow us to select neutrinos from μDAR only. (2) Due to nuclear absorption of π- and μ-, neutrinos from μ- decay are suppressed to about the $10^{-3}$ level. (3) Neutrino cross sections are well known. The inverse βdecay cross section is known to be a few percent accuracy. (4) The neutrino energy can be calculated from positron energy by adding ~1.8 MeV. (5) The anti νμand νe fluxes have different and well defined spectra. This allows us to separate oscillated signals from those due to μ- decay contamination. We propose to proceed with the oscillation search in steps since the region of Δm^2 to be searched can be anywhere between sub-eV^2 to several tens of eV^2. We start to examine the large Δm^2 region, which can be done with short baseline at first. At close distance to the MLF target gives a high neutrino flux, and allows us to use relatively small detector. If no definitive positive signal is found, a future option exists to cover small Δm^2 region. This needs a relatively long baseline and requires a large detector to compensate for the reduced neutrino flux.

physics.ins-det

Experimental search for solar hidden photons in the eV energy range using kinetic mixing with photons

We have searched for solar hidden photons in the eV energy range using a dedicated hidden photon detector. The detector consisted of a parabolic mirror with a diameter of 500mm and a focal length of 1007mm installed in a vacuum chamber, and a photomultiplier tube at its focal point. The detector was attached to the Tokyo axion helioscope, Sumico which has a mechanism to track the sun. From the result of the measurement, we found no evidence for the existence of hidden photons and set a limit on the photon-hidden photon mixing parameter χdepending on the hidden photon mass m_{γ'}.

astro-ph.SR

The Tokyo Axion Helioscope

The Tokyo Axion Helioscope experiment aims to detect axions which are produced in the solar core. The helioscope uses a strong magnetic field in order to convert axions into X-ray photons and has a mounting to follow the sun very accurately. The photons are detected by an X-ray detector which is made of 16 PIN-photodiodes. In addition, a gas container and a gas regulation system is adopted for recovering the coherence between axions and photons in the conversion region giving sensitivity to axions with masses up to 2 eV. In this paper, we report on the technical detail of the Tokyo Axion Helioscope.

astro-ph.IM

Tokyo axion helioscope experiment

A search for solar axions has been performed using an axion helioscope which is equipped with a 2.3m x 4T superconducting magnet, a gas container to hold dispersion-matching gas, PIN-photodiode X-ray detectors, and a telescope mount mechanism to track the sun. In the past measurements, axion mass up to 0.27eV have been scanned. It has been upgraded to handle dispersion-matching gas (He-4) of higher density to explore higher mass region. From December 2007 through April 2008, the axion mass region 0.84 < m < 1.00eV was newly explored, where the axions in the "photon-coupling vs. mass" parameter region of the preferred axion models were newly searched. From the absence of any evidence, a limit on axion-photon coupling constant was set to be g < 5.6-13.4e-10/GeV at 95% confidence level in the above mass region.

astro-ph.IM

Prospects of Search for Solar Axions with Mass over 1 eV and Hidden Sector Photons

We present prospects of two experiments using the Tokyo Axion Helioscope. One is a search for solar axions. In the past measurements, axion mass from 0 to 0.27 eV and from 0.84 to 1.00 eV have been scanned and no positive evidence was seen. We are now actively preparing a new phase of the experiment aiming at axion mass over 1 eV. The other is a search for hidden sector photons from the Sun. We have been designing and testing some additional equipments, which have to be installed on the helioscope to search for hidden photons with mass of over $10^{-3}$ eV.

astro-ph.IM

Tokyo Axion Helioscope

A new search result of the Tokyo axion helioscope is presented. The axion helioscope consists of a dedicated cryogen-free 4T superconducting magnet with an effective length of 2.3 m and PIN photodiodes as x-ray detectors. Solar axions, if exist, would be converted into X-ray photons through the inverse Primakoff process in the magnetic field. Conversion is coherently enhanced even for massive axions by filling the conversion region with helium gas. The present third phase measurement sets a new limit of g_{aγγ}<(5.6--13.4)\times10^{-10} GeV^{-1} for the axion mass of 0.84<m_a<1.0 eV at 95% confidence level.

astro-ph

Search for solar axions with mass around 1 eV using coherent conversion of axions into photons

A search for solar axions has been performed using an axion helioscope which is equipped with a 2.3m-long 4T superconducting magnet, a gas container to hold dispersion-matching gas, PIN-photodiode X-ray detectors, and a telescope mount mechanism to track the sun. A mass region around m_a = 1eV was newly explored. From the absence of any evidence, analysis sets a limit on axion-photon coupling constant to be g < 5.6-13.4x10^{-10} GeV^{-1} for the axion mass of 0.84<m_a<1.00eV at 95% confidence level. It is the first result to search for the axion in the g-m_a parameter region of the preferred axion models with a magnetic helioscope.

astro-ph