SearcharxivSearch

arXiv subjects

R. Ozaki

Publications and source records attributed to R. Ozaki.

5 recordsLinked to original sources

Decadal upgrade strategy for KAGRA toward post-O5 gravitational-wave astronomy

The KAGRA Collaboration has investigated a ten-year upgrade strategy for the KAGRA gravitational wave detector, considering a total of 14 upgrade options that vary in mirror mass, quantum noise reduction techniques, and the quality of cryogenic suspensions. We evaluated the scientific potential of these configurations with a focus on key targets such as parameter estimation of compact binary coalescences, binary neutron star post-merger signals, and continuous gravitational waves. Rather than aiming to improve all science cases uniformly, we prioritized those most sensitive to the detector configuration. Technical feasibility was assessed based on required hardware developments, associated R\&D efforts, cost, and risk. Our study finds that a high-frequency upgrade plan that enhances sensitivity over a broad frequency range above ~200 Hz offers the best balance between scientific return and technical feasibility. Such an upgrade would enable sky localization of binary neutron star mergers at 100 Mpc to better than 0.5 deg$^2$ in a LIGO-Virgo-KAGRA network, and improve the measurement precision of tidal deformability parameter by approximately 10% at median, compared to a network without KAGRA.

gr-qc

Identification of Noise-Associated Glitches in KAGRA O3GK with Hveto

Transient noise ("glitches") in gravitational wave detectors can mimic or obscure true signals, significantly reducing detection sensitivity. Identifying and excluding glitch-contaminated data segments is therefore crucial for enhancing the performance of gravitational-wave searches. We perform a noise analysis of the KAGRA data obtained during the O3GK observation. Our analysis is performed with hierarchical veto (Hveto) which identifies noises based on the statistical time correlation between the main channel and the auxiliary channels. A total of 2,531 noises were vetoed by 28 auxiliary channels with the configuration (i.e., signal-to-noise threshold set to 8) that we chose for Hveto. We identify vetoed events as glitches on the spectrogram via visual examination after plotting them with Q-transformation. By referring to the Gravity Spy project, we categorize 2,354 glitches into six types: blip, helix, scratchy, and scattered light, which correspond to those listed in Gravity Spy, and dot and line, which are not found in the Gravity Spy classification and are thus named based on their spectrogram morphology in KAGRA data. The remaining 177 glitches are determined not to belong to any of these six types. We show how the KAGRA glitch types are related to each subsystem of KAGRA. To investigate the possible correlation between the main channel and the round winner - an auxiliary channel statistically associated with the main channel for vetoing purposes - we visually examine the similarity or difference in the glitch pattern on the spectrogram. We compare the qualitative correlation found through visual examination with coherence, which is known to provide quantitative measurement for the correlation between the main channel and each auxiliary channel. Our comprehensive noise analysis will help improve the data quality of KAGRA by applying it to future KAGRA observation data.

gr-qc

Energy response of X-rays under high flux conditions using a thin APD for the energy range of 6-33 keV

This paper reports on the demonstration of a high-rate energy measurement technique using a thin depletion layer silicon avalanche photodiode (Si-APD). A dedicated amplitude-to-time converter is developed to realize simultaneous energy and timing measurement in a high rate condition. The energy response of the system is systematically studied by using monochromatic X-ray beam with an incident energy ranging from 6 to 33 keV. The obtained energy spectra contain clear peaks and tail distributions. The peak fraction monotonously decreases as the incident photon energy increases. This phenomenon can be explained by considering the distribution of the energy deposit in silicon, which is investigated by using a Monte Carlo simulation.

physics.ins-det

Fast X-ray detector system with simultaneous measurement of timing and energy for a single photon

We developed a fast X-ray detector system for nuclear resonant scattering (NRS) experiments. Our system employs silicon avalanche photo-diode (Si-APD) as a fast X-ray sensor. The system is able to acquire both timing and energy of a single X-ray photon simultaneously in a high rate condition, $10^6$ counts per second for one Si-APD. The performance of the system was investigated in SPring-8, a synchrotron radiation facility in Japan. Good time resolution of \SI{120}{ps} (FWHM) was achieved with a slight tail distribution in the time spectrum by a level of $10^{-9}$ at 1 ns apart from the peak. Using this system, we successfully observed the NRS from the 26.27-keV level of mercury-201, which has a half-life of $630 \pm 50$ ps. We also demonstrated the reduction of background events caused by radioactive decays in a radioactive sample by discriminating photon energy.

physics.ins-det

Nuclear resonant scattering experiment with fast time response: new scheme for observation of $^{229\rm m}$Th radiative decay

Nuclear resonant excitation of the 29.19-keV level in $^{229}$Th with high-brilliance synchrotron- radiation and detection of its decay signal, are proposed with the aim of populating the extremely low-energy isomeric state of $^{229}$Th.The proposed experiment, known as nuclear resonant scattering (NRS), has the merit of being free from uncertainties about the isomer level energy. However, it requires higher time resolution and shorter tail in the response function of the detector than that of conventional NRS experiments because of the short lifetime of the 29.19-keV state. We have fabricated an X-ray detector system which has a time resolution of 56 ps and a shorter tail function than the previously reported one. We have demonstrated an NRS experiment with the 26.27-keV nuclear level of $^{201}$Hg for feasibility assessment of the $^{229}$Th experiment. The NRS signal is clearly distinct from the prompt electronic scattering signal by the implemented detector system. The half-life of the 26.27-keV state of $^{201}$Hg is determined as 629 $\pm$ 18 ps which is better precision by a factor three than that reported to date.

nucl-ex