Searcharxiv⌕ Search

arXiv subjects

R. Pestotnik

Publications and source records attributed to R. Pestotnik.

46 records · Page 3Linked to original sources

Evidence for the Suppressed Decay B- -> DK-, D -> K+pi-

The suppressed decay chain B- -> DK-, D -> K+pi-, where D indicates a anti-D0 or D0 state, provides important information on the CP-violating angle phi_3. We measure the ratio R_{DK} of the decay rates to the favored mode B- -> DK-, D -> K-pi+ to be R_{DK} = [1.63^{+0.44}_{-0.41}(stat)^{+0.07}_{-0.13}(syst)] x 10^{-2}, which indicates the first evidence of the signal with a significance of 4.1sigma. We also measure the asymmetry A_{DK} between the charge-conjugate decays to be A_{DK} = -0.39^{+0.26}_{-0.28}(stat)^{+0.04}_{-0.03}(syst). The results are based on the full 772 x 10^6 B anti-B pair data sample collected at the Upsilon(4S) resonance with the Belle detector.

hep-ex↗

Measurement of CP violating asymmetries in B^0 -> K^+K^- K^0_S decays with a time-dependent Dalitz approach

We report a measurement of $CP$ violating asymmetries in $B^0(\overline{B}^0) \to K^+ K^- K^0_S$ decays with a time-dependent Dalitz approach. This analysis is based on a data sample of $657\times 10^6$ $B\overline{B}$ pairs accumulated at the $Υ(4S)$ resonance with the Belle detector at the KEKB asymmetric-energy $e^+e^-$ collider. As the result of an unbinned maximum likelihood fit to the selected candidates, the mixing-induced and direct $CP$ violation parameters, $ϕ^{\rm eff}_1$ and ${\cal A}_{CP}$ are obtained for $B^0 \to ϕ(1020) K^0_S$, $B^0 \to f_0(980) K^0_S$ and other $B^0 \to K^+ K^- K^0_S$ decays. We find four solutions that describe the data. There are \{eqnarray*} ϕ_1^{\rm eff}(B^0\to ϕ(1020) K^0_S) & = & (32.2 \pm 9.0 \pm 2.6 \pm 1.4)^{\circ}; ϕ_1^{\rm eff}(B^0\to ϕ(1020) K^0_S) & = & (26.2 \pm 8.8 \pm 2.7 \pm 1.2)^{\circ};\\ ϕ_1^{\rm eff}(B^0\to ϕ(1020) K^0_S) & = & (27.3 \pm 8.6 \pm 2.8 \pm 1.3)^{\circ}\; {\rm and}\\ ϕ_1^{\rm eff}(B^0\to ϕ(1020) K^0_S) & = & (24.3 \pm 8.0 \pm 2.9 \pm 5.2)^{\circ}.{eqnarray*}\ The values for the $CP$ violating phase in $B^0\to ϕ(1020) K^0_S$ are similar but other properties of the Dalitz plot are quite different for the four solutions. These four solutions have consistent $ϕ^{\rm eff}_1$ values for all three $B$ meson decay channels and none of them deviates significantly from the values measured in $B \to (c\bar{c}) K^0$ decays with the currently available statistics. In addition, we find no significant direct $CP$ violation.

hep-ex↗

First Measurement of Inclusive B -> X_s eta Decays

We report a first measurement of inclusive B -> X_s eta decays, where X_s is a charmless state with unit strangeness. The measurement is based on a pseudo-inclusive reconstruction technique and uses a sample of 657 x 10^6 BB-bar pairs accumulated with the Belle detector at the KEKB e^+e^- collider. For M_{X_s} < 2.6 GeV/c^2, we measure a branching fraction of (26.1 +/- 3.0 (stat) +1.9 -2.1 (syst) +4.0 -7.1 (model)) x 10^-5 and a direct CP asymmetry of A_{CP} = -0.13 +/- 0.04 +0.02 -0.03. Over half of the signal occurs in the range M_{X_s} > 1.8 GeV/c^2.

hep-ex↗

Measurements of Cherenkov Photons with Silicon Photomultipliers

A novel photon detector, the Silicon Photomultiplier (SiPM), has been tested in proximity focusing Ring Imaging Cherenkov (RICH) counters that were exposed to cosmic-ray particles in Ljubljana, and a 2 GeV electron beam at the KEK research facility. This type of RICH detector is a candidate for the particle identification detector upgrade of the BELLE detector at the KEK B-factory, for which the use of SiPMs, microchannel plate photomultiplier tubes or hybrid avalanche photodetectors, rather than traditional Photomultiplier Tubes (PMTs) is essential due to the presence of high magnetic fields. In both experiments, SiPMs are found to compare favourably with PMTs, with higher photon detection rates per unit area. Through the use of hemispherical and truncated pyramid light guides to concentrate photons onto the active surface area, the light yield increases significantly. An estimate of the contribution to dark noise from false coincidences between SiPMs in an array is also presented.

physics.ins-det↗

sBelle Design Study Report

In this note, we compile results of various simulation studies for the upgrade of the Belle detector. Based on these studies, we propose a set of optimum or appropriate parameters of the detector.

hep-ex↗

A novel type of proximity focusing RICH counter with multiple refractive index aerogel radiator

A proximity focusing ring imaging Cherenkov detector, with the radiator consisting of two or more aerogel layers of different refractive indices, has been tested in 1-4 GeV/c pion beams at KEK. Essentially, a multiple refractive index aerogel radiator allows for an increase in Cherenkov photon yield on account of the increase in overall radiator thickness, while avoiding the simultaneous degradation in single photon angular resolution associated with the increased uncertainty of the emission point. With the refractive index of consecutive layers suitably increasing in the downstream direction, one may achieve overlapping of the Cherenkov rings from a single charged particle. In the opposite case of decreasing refractive index, one may obtain well separated rings. In the former combination an approximately 40% increase in photon yield is accompanied with just a minor degradation in single photon angular resolution. The impact of this improvement on the pion/kaon separation at the upgraded Belle detector is discussed.

physics.ins-det↗

Studies of Proximity Focusing RICH with an aerogel radiator using Flat-panel multi-anode PMTs (Hamamatsu H8500)

A proximity focusing ring imaging Cherenkov detector using aerogel as the radiator has been studied for an upgrade of the Belle detector at the KEK-B-factory. We constructed a prototype Cherenkov counter using a 4 x 4 array of 64-channel flat-panel multi-anode PMTs (Hamamatsu H8500) with a large effective area. The aerogel samples were made with a new technique to obtain a higher transmission length at a high refractive index (n=1.05). Multi-channel PMTs are read-out with analog memory chips. The detector was tested at the KEK-PS pi2 beam line in November, 2002. To evaluate systematically the performance of the detector, tests were carried out with various aerogel samples using pion beams with momenta between 0.5 GeV/c and 4 GeV/c. The typical angular resolution was around 14 mrad, and the average number of detected photoelectrons was around 6. We expect that pions and kaons can be separated at a 4 sigma level at 4 GeV/c.

physics.ins-det↗

Tests of a proximity focusing RICH with aerogel as radiator

Using aerogel as radiator and multianode PMTs for photon detection, a proximity focusing Cherenkov ring imaging detector has been constructed and tested in the KEK $π$2 beam. The aim is to experimentally study the basic parameters such as resolution of the single photon Cherenkov angle and number of detected photons per ring. The resolution obtained is well approximated by estimates of contributions from pixel size and emission point uncertainty. The number of detected photons per Cherenkov ring is in good agreement with estimates based on aerogel and detector characteristics. The values obtained turn out to be rather low, mainly due to Rayleigh scattering and to the relatively large dead space between the photocathodes. A light collection system or a higher fraction of the photomultiplier active area, together with better quality aerogels are expected to improve the situation. The reduction of Cherenkov yield, for charged particle impact in the vicinity of the aerogel tile side wall, has also been measured.

hep-ex↗