Searcharxiv⌕ Search

arXiv subjects

R. R. Fan

Publications and source records attributed to R. R. Fan.

23 records · Page 2Linked to original sources

Internal alignment and position resolution of the silicon tracker of DAMPE determined with orbit data

The DArk Matter Particle Explorer (DAMPE) is a space-borne particle detector designed to probe electrons and gamma-rays in the few GeV to 10 TeV energy range, as well as cosmic-ray proton and nuclei components between 10 GeV and 100 TeV. The silicon-tungsten tracker-converter is a crucial component of DAMPE. It allows the direction of incoming photons converting into electron-positron pairs to be estimated, and the trajectory and charge (Z) of cosmic-ray particles to be identified. It consists of 768 silicon micro-strip sensors assembled in 6 double layers with a total active area of 6.6 m$^2$. Silicon planes are interleaved with three layers of tungsten plates, resulting in about one radiation length of material in the tracker. Internal alignment parameters of the tracker have been determined on orbit, with non-showering protons and helium nuclei. We describe the alignment procedure and present the position resolution and alignment stability measurements.

physics.ins-det↗

Direct detection of a break in the teraelectronvolt cosmic-ray spectrum of electrons and positrons

High energy cosmic ray electrons plus positrons (CREs), which lose energy quickly during their propagation, provide an ideal probe of Galactic high-energy processes and may enable the observation of phenomena such as dark-matter particle annihilation or decay. The CRE spectrum has been directly measured up to $\sim 2$ TeV in previous balloon- or space-borne experiments, and indirectly up to $\sim 5$ TeV by ground-based Cherenkov $γ$-ray telescope arrays. Evidence for a spectral break in the TeV energy range has been provided by indirect measurements of H.E.S.S., although the results were qualified by sizeable systematic uncertainties. Here we report a direct measurement of CREs in the energy range $25~{\rm GeV}-4.6~{\rm TeV}$ by the DArk Matter Particle Explorer (DAMPE) with unprecedentedly high energy resolution and low background. The majority of the spectrum can be properly fitted by a smoothly broken power-law model rather than a single power-law model. The direct detection of a spectral break at $E \sim0.9$ TeV confirms the evidence found by H.E.S.S., clarifies the behavior of the CRE spectrum at energies above 1 TeV and sheds light on the physical origin of the sub-TeV CREs.

astro-ph.HE↗

The DArk Matter Particle Explorer mission

The DArk Matter Particle Explorer (DAMPE), one of the four scientific space science missions within the framework of the Strategic Pioneer Program on Space Science of the Chinese Academy of Sciences, is a general purpose high energy cosmic-ray and gamma-ray observatory, which was successfully launched on December 17th, 2015 from the Jiuquan Satellite Launch Center. The DAMPE scientific objectives include the study of galactic cosmic rays up to $\sim 10$ TeV and hundreds of TeV for electrons/gammas and nuclei respectively, and the search for dark matter signatures in their spectra. In this paper we illustrate the layout of the DAMPE instrument, and discuss the results of beam tests and calibrations performed on ground. Finally we present the expected performance in space and give an overview of the mission key scientific goals.

astro-ph.IM↗

Observation of $χ_{c1}$ decays into vector meson pairs $ϕϕ$, $ωω$, and $ωϕ$

Decays of $χ_{c1}$ to vector meson pairs $ϕϕ$, $ωω$ and $ωϕ$ are observed for the first time using $(106\pm4)\times 10^6$ $\psip$ events accumulated at the BESIII detector at the BEPCII $e^+e^-$ collider. The branching fractions are measured to be $(4.4\pm 0.3\pm 0.5)\times 10^{-4}$, $(6.0\pm 0.3\pm 0.7)\times 10^{-4}$, and $(2.2\pm 0.6\pm 0.2)\times 10^{-5}$, for $χ_{c1}\to ϕϕ$, $ωω$, and $ωϕ$, respectively. The observation of $χ_{c1}$ decays into a pair of vector mesons $ϕϕ$, $ωω$ and $ωϕ$ indicates that the hadron helicity selection rule is significantly violated in $χ_{cJ}$ decays. In addition, the measurement of $χ_{cJ}\to ωϕ$ gives the rate of doubly OZI-suppressed decay. Branching fractions for $χ_{c0}$ and $χ_{c2}$ decays into other vector meson pairs are also measured with improved precision.

hep-ex↗

The silicon matrix for the prototype for the Dark Matter Particle Explorer

A new generation detector for the high energy cosmic ray - the DAMPE(DArk Matter Particle Explorer) is a satellite based project. Its main object is the measurement of energy spectrum of cosmic ray nuclei from 100GeV to 100TeV, the high energy electrons and gamma ray from 5GeV to 10TeV. A silicon matrix detector described in this paper, is employed for the sea level cosmic ray energy and position detection while the prototype testing of the DAMPE. This matrix is composed by the 180 silicon PIN detectors, which covers an area of 32*20 cm2. The primary testing results are shown including MIPs energy spectrum and the position sensitive map.

physics.ins-det↗