Searcharxiv⌕ Search

arXiv subjects

R. R. Mammei

Publications and source records attributed to R. R. Mammei.

9 recordsLinked to original sources

Characterization of Low-energy Ionization Signals in Silicon Detectors for the Nab Experiment

The Nab (Neutron a b) experiment is designed to measure the beta-antineutrino angular correlation in free neutron $β$ decay with an ultimate precision goal of 0.1%, providing input for tests of Cabibbo-Kobayashi-Maskawa (CKM) matrix unitarity. This measurement is performed via detection of electrons and protons in delayed coincidence using custom large-area segmented silicon detectors. We present the characterization of one such detector system to establish the proton energy and timing response, using a dedicated proton accelerator. The detected proton peak was studied for 25 keV, 30 keV, and 35 keV incident protons on a set of detector segments and multiple cooling cycles over a one year period. Ionization losses were consistent with models of the detector dead layer with thicknesses less than 100 nm. The detected proton peak was stable within the uncertainty from energy calibration (0.25 keV). The rise times of detector pulses from $^{109}$Cd and $^{113}$Sn conversion electron sources were used to extract the impurity density profile and establish a precise model for the detector timing response. The observed impurity density profile varied from $(2 \pm 2) \times 10^9$ cm$^{-3}$ at the center to $(26 \pm 2) \times 10^9$ cm$^{-3}$ at the edge. This impurity density profile was then used to characterize systematic effects in proton time-of-flight measurements due to detector pulse-shape effects; the resultant proton timing systematic uncertainties were below 0.3 ns, which is sufficient for the Nab experiment.

physics.ins-det↗

A Flexible Data Acquisition System Architecture for the Nab Experiment

The Nab experiment will measure the electron-neutrino correlation and Fierz interference term in free neutron beta decay to test the Standard Model and probe Beyond the Standard Model Physics. Using National Instrument's PXIe-5171 Reconfigurable Oscilloscope module, we have developed a data acquisition system that is not only capable of meeting Nab's specifications, but flexible enough to be adapted in situ as the experimental environment dictates. The L1 and L2 trigger logic can be reconfigured to optimize the system for coincidence event detection at runtime through configuration files and LabVIEW controls. This system is capable of identifying L1 triggers at at least $1$ MHz, while reading out a peak signal rate of approximately $2$ GB/s. During commissioning, the system ran at a sustained readout rate of $400$ MB/s of signal data originating from roughly $6$ kHz L2 triggers, well within the peak performance of the system.

physics.ins-det↗

Final results for the neutron $β$-asymmetry parameter $A_0$ from the UCNA experiment

The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.

nucl-ex↗

Using Nab to determine correlations in unpolarized neutron decay

The Nab experiment will measure the ratio of the weak axial-vector and vector coupling constants $λ=g_A/g_V$ with precision $δλ/λ\sim3\times10^{-4}$ and search for a Fierz term $b_F$ at a level $Δb_F<10^{-3}$. The Nab detection system uses thick, large area, segmented silicon detectors to very precisely determine the decay proton's time of flight and the decay electron's energy in coincidence and reconstruct the correlation between the antineutrino and electron momenta. Excellent understanding of systematic effects affecting timing and energy reconstruction using this detection system are required. To explore these effects, a series of ex situ studies have been undertaken, including a search for a Fierz term at a less sensitive level of $Δb_F<10^{-2}$ in the beta decay of $^{45}$Ca using the UCNA spectrometer.

nucl-ex↗

First direct constraints on Fierz interference in free neutron $β$ decay

Precision measurements of free neutron $β$-decay have been used to precisely constrain our understanding of the weak interaction. However the neutron Fierz interference term $b_n$, which is particularly sensitive to Beyond-Standard-Model tensor currents at the TeV scale, has thus far eluded measurement. Here we report the first direct constraints on this term, finding $b_n = 0.067 \pm 0.005_{\text{stat}} {}^{+0.090}_{- 0.061}{}_{\text{sys}}$, consistent with the Standard Model. The uncertainty is dominated by absolute energy reconstruction and the linearity of the beta spectrometer energy response.

nucl-ex↗

Sensitivity of Fields Generated within Magnetically Shielded Volumes to Changes in Magnetic Permeability

Future experiments seeking to measure the neutron electric dipole moment (nEDM) require stable and homogeneous magnetic fields. Normally these experiments use a coil internal to a passively magnetically shielded volume to generate the magnetic field. The stability of the magnetic field generated by the coil within the magnetically shielded volume may be influenced by a number of factors. The factor studied here is the dependence of the internally generated field on the magnetic permeability $μ$ of the shield material. We provide measurements of the temperature-dependence of the permeability of the material used in a set of prototype magnetic shields, using experimental parameters nearer to those of nEDM experiments than previously reported in the literature. Our measurements imply a range of $\frac{1}μ\frac{dμ}{dT}$ from 0-2.7\%/K. Assuming typical nEDM experiment coil and shield parameters gives $\fracμ{B_0}\frac{dB_0}{dμ}=0.01$, resulting in a temperature dependence of the magnetic field in a typical nEDM experiment of $\frac{dB_0}{dT}=0-270$~pT/K for $B_0=1~μ$T. The results are useful for estimating the necessary level of temperature control in nEDM experiments.

physics.ins-det↗

Precision Measurement of the Neutron Beta-Decay Asymmetry

A new measurement of the neutron $β$-decay asymmetry $A_0$ has been carried out by the UCNA collaboration using polarized ultracold neutrons (UCN) from the solid deuterium UCN source at the Los Alamos Neutron Science Center (LANSCE). Improvements in the experiment have led to reductions in both statistical and systematic uncertainties leading to $A_0 = -0.11954(55)_{\rm stat.}(98)_{\rm syst.}$, corresponding to the ratio of axial-vector to vector coupling $λ\equiv g_A/g_V = -1.2756(30)$.

nucl-ex↗

Measurement of the neutron $β$-asymmetry parameter $A_0$ with ultracold neutrons

We present a detailed report of a measurement of the neutron $β$-asymmetry parameter $A_0$, the parity-violating angular correlation between the neutron spin and the decay electron momentum, performed with polarized ultracold neutrons (UCN). UCN were extracted from a pulsed spallation solid deuterium source and polarized via transport through a 7-T magnetic field. The polarized UCN were then transported through an adiabatic-fast-passage spin-flipper field region, prior to storage in a cylindrical decay volume situated within a 1-T $2 \times 2π$ solenoidal spectrometer. The asymmetry was extracted from measurements of the decay electrons in multiwire proportional chamber and plastic scintillator detector packages located on both ends of the spectrometer. From an analysis of data acquired during runs in 2008 and 2009, we report $A_0 = -0.11966 \pm 0.00089_{-0.00140} ^{+0.00123}$, from which we extract a value for the ratio of the weak axial-vector and vector coupling constants of the nucleon, $λ= g_A/g_V = -1.27590 \pm 0.00239_{-0.00377}^{+0.00331}$. Complete details of the analysis are presented.

nucl-ex↗

Determination of the Axial-Vector Weak Coupling Constant with Ultracold Neutrons

A precise measurement of the neutron decay $β$-asymmetry $A_0$ has been carried out using polarized ultracold neutrons (UCN) from the pulsed spallation UCN source at the Los Alamos Neutron Science Center (LANSCE). Combining data obtained in 2008 and 2009, we report $A_0 = -0.11966 \pm 0.00089_{-0.00140}^{+0.00123}$, from which we determine the ratio of the axial-vector to vector weak coupling of the nucleon $g_A/g_V = -1.27590_{-0.00445}^{+0.00409}$.

nucl-ex↗