TRIDENT: an Infrared Differential Imaging Camera Optimized for the Detection of Methanated Substellar Companions

A near-infrared camera in use at the Canada-France-Hawaii Telescope (CFHT) and at the 1.6-m telescope of the Observatoire du Mont-Megantic is described. The camera is based on a Hawaii-1 1024x1024 HgCdTe array detector. Its main feature is to acquire three simultaneous images at three wavelengths across the methane absorption bandhead at 1.6 microns, enabling, in theory, an accurate subtraction of the stellar point spread function (PSF) and the detection of faint close methanated companions. The instrument has no coronagraph and features fast data acquisition, yielding high observing efficiency on bright stars. The performance of the instrument is described, and it is illustrated by laboratory tests and CFHT observations of the nearby stars GL526, Ups And and Chi And. TRIDENT can detect (6 sigma) a methanated companion with delta H = 9.5 at 0.5" separation from the star in one hour of observing time. Non-common path aberrations and amplitude modulation differences between the three optical paths are likely to be the limiting factors preventing further PSF attenuation. Instrument rotation and reference star subtraction improve the detection limit by a factor of 2 and 4 respectively. A PSF noise attenuation model is presented to estimate the non-common path wavefront difference effect on PSF subtraction performance.

astro-ph

Differential Imaging with a Multicolor Detector Assembly: A New ExoPlanet Finder Concept

Simultaneous spectral differential imaging is a high contrast technique by which subtraction of simultaneous images reduces noise from atmospheric speckles and optical aberrations. Small non-common wave front errors between channels can seriously degrade its performance. We present a new concept, a multicolor detector assembly (MCDA), which can eliminate this problem. The device consists of an infrared detector and a microlens array onto the flat side of which a checkerboard pattern of narrow-band micro-filters is deposited, each micro-filter coinciding with a microlens. Practical considerations for successful implementation of the technique are mentioned. Numerical simulations predict a noise attenuation of 10^-3 at 0.5" for a 10^5 seconds integration on a mH=5 star of Strehl ratio 0.9 taken with an 8-m telescope. This reaches a contrast of 10^-7 at an angular distance of 0.5" from the center of the star image.

astro-ph

Effects of Quasi-Static Aberrations in Faint Companion Searches

We present the first results obtained at CFHT with the TRIDENT infrared camera, dedicated to the detection of faint companions close to bright nearby stars. The camera's main feature is the acquisition of three simultaneous images in three wavelengths (simultaneous differential imaging) across the methane absorption bandhead at 1.6 micron, that enables a precise subtraction of the primary star PSF while keeping the companion signal. The main limitation is non-common path aberrations between the three optical paths that slightly decorrelate the PSFs. Two types of PSF calibrations are combined with the differential simultaneous imaging technique to further attenuate the PSF: reference star subtraction and instrument rotation to smooth aberrations. It is shown that a faint companion with a DeltaH of 10 magnitudes would be detected at 0.5 arcsec from the primary.

astro-ph

TRIDENT: an infrared camera optimized for the detection of methanated substellar companions around nearby stars

A near-infrared (0.85-2.5 microns) camera in use at the Canada-France-Hawaii Telescope and at the 1.6m telescope of the Observatoire du Mont-Megantic is described. The camera is based on a Hawaii-1 1024x1024 HgCdTe array detector. Its main feature is to acquire three simultaneous images at three wavelengths (simultaneous differential imaging) across the methane absorption bandhead at 1.6 micron, enabling an accurate subtraction of the stellar point spread function (PSF) and the detection of faint close methanated companions. The instrument has no coronagraph and features a fast (1 MHz) data acquisition system without reset anomaly, yielding high observing efficiencies on bright stars. The performance of the instrument is described, and it is illustrated by CFHT images of the nearby star Ups And. TRIDENT can detect (3 sigma) a methanated companion with DeltaH=10 at 0.5 arcsec from the star in one hour of observing time. Non-common path aberrations between the three optical paths are the limiting factors preventing further PSF attenuation. Reference star subtraction and instrument rotation improve the detection limit by one order of magnitude.

astro-ph

Differential Simultaneous Imaging and Faint Companions: TRIDENT First Results from CFHT

We present the first results obtained at CFHT with the TRIDENT infrared camera, dedicated to the detection of faint companions close to bright nearby stars. Its main feature is the acquisition of three simultaneous images in three wavelengths (simultaneous differential imaging) across the methane absorption bandhead at 1.6 micron, that enables a precise subtraction of the primary star PSF while keeping the companion signal. Thirty-five stars have been observed in two observing missions, with no detection so far. It is shown that a faint companion with a DeltaH of 10 magnitudes would be detected at 0.5 arcsec from the primary.

astro-ph

Searching for Faint Companions with the TRIDENT Differential Simultaneous Imaging Camera

We present the first results obtained at CFHT with the TRIDENT infrared camera, dedicated to the detection of faint companions close to bright nearby stars. Its main feature is the acquisition of three simultaneous images in three wavelengths (simultaneous differential imaging) across the methane absorption bandhead at 1.6 micron, that enables a precise subtraction of the primary star PSF while keeping the companion signal. Gl229 and 55Cnc observations are presented to demonstrate TRIDENT subtraction performances. It is shown that a faint companion with a DeltaH of 10 magnitudes would be detected at 0.5 arcsec from the primary.