Searcharxiv⌕ Search

arXiv subjects

R. Rogly

Publications and source records attributed to R. Rogly.

32 records · Page 2Linked to original sources

Performance of SK-Gd's Upgraded Real-time Supernova Monitoring System

Among multi-messenger observations of the next galactic core-collapse supernova, Super-Kamiokande (SK) plays a critical role in detecting the emitted supernova neutrinos, determining the direction to the supernova (SN), and notifying the astronomical community of these observations in advance of the optical signal. On 2022, SK has increased the gadolinium dissolved in its water target (SK-Gd) and has achieved a Gd concentration of 0.033%, resulting in enhanced neutron detection capability, which in turn enables more accurate determination of the supernova direction. Accordingly, SK-Gd's real-time supernova monitoring system (Abe te al. 2016b) has been upgraded. SK_SN Notice, a warning system that works together with this monitoring system, was released on December 13, 2021, and is available through GCN Notices (Barthelmy et al. 2000). When the monitoring system detects an SN-like burst of events, SK_SN Notice will automatically distribute an alarm with the reconstructed direction to the supernova candidate within a few minutes. In this paper, we present a systematic study of SK-Gd's response to a simulated galactic SN. Assuming a supernova situated at 10 kpc, neutrino fluxes from six supernova models are used to characterize SK-Gd's pointing accuracy using the same tools as the online monitoring system. The pointing accuracy is found to vary from 3-7$^\circ$ depending on the models. However, if the supernova is closer than 10 kpc, SK_SN Notice can issue an alarm with three-degree accuracy, which will benefit follow-up observations by optical telescopes with large fields of view.

astro-ph.HE↗

Solar neutrino measurements using the full data period of Super-Kamiokande-IV

An analysis of solar neutrino data from the fourth phase of Super-Kamiokande~(SK-IV) from October 2008 to May 2018 is performed and the results are presented. The observation time of the data set of SK-IV corresponds to $2970$~days and the total live time for all four phases is $5805$~days. For more precise solar neutrino measurements, several improvements are applied in this analysis: lowering the data acquisition threshold in May 2015, further reduction of the spallation background using neutron clustering events, precise energy reconstruction considering the time variation of the PMT gain. The observed number of solar neutrino events in $3.49$--$19.49$ MeV electron kinetic energy region during SK-IV is $65,443^{+390}_{-388}\,(\mathrm{stat.})\pm 925\,(\mathrm{syst.})$ events. Corresponding $\mathrm{^{8}B}$ solar neutrino flux is $(2.314 \pm 0.014\, \rm{(stat.)} \pm 0.040 \, \rm{(syst.)}) \times 10^{6}~\mathrm{cm^{-2}\,s^{-1}}$, assuming a pure electron-neutrino flavor component without neutrino oscillations. The flux combined with all SK phases up to SK-IV is $(2.336 \pm 0.011\, \rm{(stat.)} \pm 0.043 \, \rm{(syst.)}) \times 10^{6}~\mathrm{cm^{-2}\,s^{-1}}$. Based on the neutrino oscillation analysis from all solar experiments, including the SK $5805$~days data set, the best-fit neutrino oscillation parameters are $\rm{sin^{2} θ_{12,\,solar}} = 0.306 \pm 0.013 $ and $Δm^{2}_{21,\,\mathrm{solar}} = (6.10^{+ 0.95}_{-0.81}) \times 10^{-5}~\rm{eV}^{2}$, with a deviation of about 1.5$σ$ from the $Δm^{2}_{21}$ parameter obtained by KamLAND. The best-fit neutrino oscillation parameters obtained from all solar experiments and KamLAND are $\sin^{2} θ_{12,\,\mathrm{global}} = 0.307 \pm 0.012 $ and $Δm^{2}_{21,\,\mathrm{global}} = (7.50^{+ 0.19}_{-0.18}) \times 10^{-5}~\rm{eV}^{2}$.

hep-ex↗

A Plastic Scintillation Muon Veto for Sub-Kelvin Temperatures

Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon vetos are essential to reduce the detector background and to reach the sensitivity goals. We demonstrate the feasibility of deploying organic plastic scintillators at sub-Kelvin temperatures. For the NUCLEUS experiment, we developed a cryogenic muon veto equipped with wavelength shifting fibers and a silicon photo multiplier operating inside a dilution refrigerator. The achievable compactness of cryostat-internal integration is a key factor in keeping the muon rate to a minimum while maximizing coverage. The thermal and light output properties of a plastic scintillation detector were examined. We report first data on the thermal conductivity and heat capacity of the polystyrene-based scintillator UPS-923A over a wide range of temperatures extending below one Kelvin. The light output was measured down to 0.8K and observed to increase by a factor of 1.61$\pm$0.05 compared to 300K. The development of an organic plastic scintillation muon veto operating in sub-Kelvin temperature environments opens new perspectives for rare-event searches with cryogenic detectors at sites lacking substantial overburden.

physics.ins-det↗

Observation of a nuclear recoil peak at the 100 eV scale induced by neutron capture

Coherent elastic neutrino-nucleus scattering and low-mass Dark Matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observation of a nuclear recoil peak at around 112 eV induced by neutron capture. The measurement was performed with a CaWO$_4$ cryogenic detector from the NUCLEUS experiment exposed to a $^{252}$Cf source placed in a compact moderator. The measured spectrum is found in agreement with simulations and the expected peak structure from the single-$γ$ de-excitation of $^{183}$W is identified with 3 $σ$ significance. This result demonstrates a new method for precise, in-situ, and non-intrusive calibration of low-threshold experiments.

nucl-ex↗

Exploring coherent elastic neutrino-nucleus scattering of reactor neutrinos with the NUCLEUS experiment

The NUCLEUS experiment aims to perform a high-precision measurement of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) at the EdF Chooz B nuclear power plant in France. CEvNS is a unique process to study neutrino properties and to search for physics beyond the Standard Model. The study of CEvNS is also important for light Dark-Matter searches. It could be a possible irreducible background for high-sensitivity Dark-Matter searches. NUCLEUS is an experiment under construction based on ultra-low threshold (20 eVnr) cryogenic calorimeters, operated at tens-of-mK temperatures.

physics.ins-det↗

Improved FIFRELIN de-excitation model for neutrino applications

The precise modeling of the de-excitation of Gd isotopes is of great interest for experimental studies of neutrinos using Gd-loaded organic liquid scintillators. The FIFRELIN code was recently used within the purposes of the STEREO experiment for the modeling of the Gd de-excitation after neutron capture in order to achieve a good control of the detection efficiency. In this work, we report on the recent additions in the FIFRELIN de-excitation model with the purpose of enhancing further the de-excitation description. Experimental transition intensities from EGAF database are now included in the FIFRELIN cascades, in order to improve the description of the higher energy part of the spectrum. Furthermore, the angular correlations between γ rays are now implemented in FIFRELIN, to account for the relative anisotropies between them. In addition, conversion electrons are now treated more precisely in the whole spectrum range, while the subsequent emission of X rays is also accounted for. The impact of the aforementioned improvements in FIFRELIN is tested by simulating neutron captures in various positions inside the STEREO detector. A repository of up-to-date FIFRELIN simulations of the Gd isotopes is made available for the community, with the possibility of expanding for other isotopes which can be suitable for different applications.

hep-ex↗

Development of a compact muon veto for the NUCLEUS experiment

The NUCLEUS experiment aims to measure coherent elastic neutrino nucleus scattering of reactor anti-neutrinos using cryogenic calorimeters. Operating at an overburden of 3 m.w.e., muon-induced backgrounds are expected to be one of the dominant background contributions. Besides a high efficiency to identify muon events passing the experimental setup, the NUCLEUS muon veto has to fulfill tight spatial requirements to fit the constraints given by the experimental site and to minimize the induced detector dead-time. We developed highly efficient and compact muon veto modules based on plastic scintillators equipped with wavelength shifting fibers and silicon photo multipliers to collect and detect the scintillation light. In this paper, we present the full characterization of a prototype module with different light read-out configurations. We conclude that an efficient and compact muon veto system can be built for the NUCLEUS experiment from a cube assembly of the developed modules. Simulations show that an efficiency for muon identification of >99 % and an associated rate of 325 Hz is achievable, matching the requirements of the NUCLEUS experiment.

physics.ins-det↗

Searching for Hidden Neutrons with a Reactor Neutrino Experiment: Constraints from the STEREO Experiment

Different extensions of the standard model of particle physics, such as braneworld or mirror matter models, predict the existence of a neutron sterile state, possibly as a dark matter candidate. This Letter reports a new experimental constraint on the probability $p$ for neutron conversion into a hidden neutron, set by the STEREO experiment at the high flux reactor of the Institut Laue-Langevin. The limit is $p<3.1\times 10^{-11}$ at $95 \%$ C.L. improving the previous limit by a factor 13. This result demonstrates that short-baseline neutrino experiments can be used as competitive passing-through-walls neutron experiments to search for hidden neutrons.

hep-ex↗

Joint Measurement of the $^{235}$U Antineutrino Spectrum by Prospect and Stereo

The PROSPECT and STEREO collaborations present a combined measurement of the pure $^{235}$U antineutrino spectrum, without site specific corrections or detector-dependent effects. The spectral measurements of the two highest precision experiments at research reactors are found to be compatible with $χ^2/\mathrm{ndf} = 24.1/21$, allowing a joint unfolding of the prompt energy measurements into antineutrino energy. This $\barν_e$ energy spectrum is provided to the community, and an excess of events relative to the Huber model is found in the 5-6 MeV region. When a Gaussian bump is fitted to the excess, the data-model $χ^2$ value is improved, corresponding to a $2.4σ$ significance.

nucl-ex↗

First antineutrino energy spectrum from $^{235}$U fissions with the STEREO detector at ILL

This article reports the measurement of the $^{235}$U-induced antineutrino spectrum shape by the STEREO experiment. 43'000 antineutrinos have been detected at about 10 m from the highly enriched core of the ILL reactor during 118 full days equivalent at nominal power. The measured inverse beta decay spectrum is unfolded to provide a pure $^{235}$U spectrum in antineutrino energy. A careful study of the unfolding procedure, including a cross-validation by an independent framework, has shown that no major biases are introduced by the method. A significant local distortion is found with respect to predictions around $E_ν\simeq 5.3$ MeV. A gaussian fit of this local excess leads to an amplitude of $A = 12.1 \pm 3.4\%$ (3.5$σ$).

hep-ex↗

Calibration of nuclear recoils at the 100 eV scale using neutron capture

The development of low-threshold detectors for the study of coherent elastic neutrino-nucleus scattering and for the search for light dark matter necessitates methods of low-energy calibration. We suggest this can be provided by the nuclear recoils resulting from the $γ$ emission following thermal neutron capture. In particular, several MeV-scale single-$γ$ transitions induce well-defined nuclear recoil peaks in the 100 eV range. Using the FIFRELIN code, complete schemes of $γ$-cascades for various isotopes can be predicted with high accuracy to determine the continuous background of nuclear recoils below the calibration peaks. We present a comprehensive experimental concept for the calibration of CaWO$_4$ and Ge cryogenic detectors at a research reactor. For CaWO$_4$ the simulations show that two nuclear recoil peaks at 112.5 eV and 160.3 eV should be visible above background simply in the spectrum of the cryogenic detector. Then we discuss how the additional tagging for the associated $γ$ increases the sensitivity of the method and extends its application to a wider energy range and to Ge cryogenic detectors.

physics.ins-det↗

Accurate Measurement of the Electron Antineutrino Yield of U-235 Fissions from the STEREO Experiment with 119 Days of Reactor-On Data

We report a measurement of the antineutrino rate from the fission of U-235 with the STEREO detector using 119 days of reactor turned on. In our analysis, we perform several detailed corrections and achieve the most precise single measurement at reactors with highly enriched U-235 fuel. We measure an IBD cross section per fission of $σ_f$ = (6.34 $\pm$ 0.06 [stat] $\pm$ 0.15 [sys] $\pm$ 0.15 [model]) $\times$ 10${}^{-43}$ cm${}^{2}$/fission and observe a rate deficit of (5.2 $\pm$ 0.8 [stat] $\pm$ 2.3 [sys] $\pm$ 2.3 [model])% compared to the model, consistent with the deficit of the world average. Testing U-235 as the sole source of the deficit, we find a tension between the results of lowly and highly enriched U-235 fuel of 2.1 standard deviations.

hep-ex↗

Improved Sterile Neutrino Constraints from the STEREO Experiment with 179 Days of Reactor-On Data

The STEREO experiment is a very short baseline reactor antineutrino experiment. It is designed to test the hypothesis of light sterile neutrinos being the cause of a deficit of the observed antineutrino interaction rate at short baselines with respect to the predicted rate, known as the reactor antineutrino anomaly. The STEREO experiment measures the antineutrino energy spectrum in six identical detector cells covering baselines between 9 and 11 m from the compact core of the ILL research reactor. In this article, results from 179 days of reactor turned on and 235 days of reactor turned off are reported at a high degree of detail. The current results include improvements in the modelling of detector optical properties and the gamma-cascade after neutron captures by gadolinium, the treatment of backgrounds, and the statistical method of the oscillation analysis. Using a direct comparison between antineutrino spectra of all cells, largely independent of any flux prediction, we find the data compatible with the null oscillation hypothesis. The best-fit point of the reactor antineutrino anomaly is rejected at more than 99.9% C.L.

hep-ex↗

Note on arXiv:2005.05301, 'Preparation of the Neutrino-4 experiment on search for sterile neutrino and the obtained results of measurements'

We comment on the claimed observation [arXiv:arXiv:2005.05301] of sterile neutrino oscillations by the Neutrino-4 collaboration. Such a claim, which requires the existence of a new fundamental particle, demands a level of rigor commensurate with its impact. The burden lies with the Neutrino-4 collaboration to provide the information necessary to prove the validity of their claim to the community. In this note, we describe aspects of both the data and analysis method that might lead to an oscillation signature arising from a null experiment and describe additional information needed from the Neutrino-4 collaboration to support the oscillation claim. Additionally, as opposed to the assertion made by the Neutrino-4 collaboration, we also show that the method of 'coherent summation' using the $L/E$ parameter produces similar results to the methods used by the PROSPECT and the STEREO collaborations.

hep-ex↗