Searcharxiv⌕ Search

arXiv subjects

R. Rosero

Publications and source records attributed to R. Rosero.

At least 55 records · Page 3Linked to original sources

Joint Measurement of the $^{235}$U Antineutrino Spectrum by Prospect and Stereo

The PROSPECT and STEREO collaborations present a combined measurement of the pure $^{235}$U antineutrino spectrum, without site specific corrections or detector-dependent effects. The spectral measurements of the two highest precision experiments at research reactors are found to be compatible with $χ^2/\mathrm{ndf} = 24.1/21$, allowing a joint unfolding of the prompt energy measurements into antineutrino energy. This $\barν_e$ energy spectrum is provided to the community, and an excess of events relative to the Huber model is found in the 5-6 MeV region. When a Gaussian bump is fitted to the excess, the data-model $χ^2$ value is improved, corresponding to a $2.4σ$ significance.

nucl-ex↗

Theia: An advanced optical neutrino detector

New developments in liquid scintillators, high-efficiency, fast photon detectors, and chromatic photon sorting have opened up the possibility for building a large-scale detector that can discriminate between Cherenkov and scintillation signals. Such a detector could exploit these two distinct signals to observe particle direction and species using Cherenkov light while also having the excellent energy resolution and low threshold of a scintillator detector. Situated in a deep underground laboratory, and utilizing new techniques in computing and reconstruction techniques, such a detector could achieve unprecedented levels of background rejection, thus enabling a rich physics program that would span topics in nuclear, high-energy, and astrophysics, and across a dynamic range from hundreds of keV to many GeV. The scientific program would include observations of low- and high-energy solar neutrinos, determination of neutrino mass ordering and measurement of the neutrino CP violating phase, observations of diffuse supernova neutrinos and neutrinos from a supernova burst, sensitive searches for nucleon decay and, ultimately, a search for NeutrinoLess Double Beta Decay (NLDBD) with sensitivity reaching the normal ordering regime of neutrino mass phase space. This paper describes Theia, a detector design that incorporates these new technologies in a practical and affordable way to accomplish the science goals described above. We consider two scenarios, one in which Theia would reside in a cavern the size and shape of the caverns intended to be excavated for the Deep Underground Neutrino Experiment (DUNE) which we call Theia 25, and a larger 100 ktonne version (Theia 100) that could achieve an even broader and more sensitive scientific program.

physics.ins-det↗

A Spectrometric Approach to Measuring the Rayleigh Scattering Length for Liquid Scintillator Detectors

Good optical transparency is a fundamental requirement of liquid scintillator (LS) detectors. Characterizing the transparency of a liquid scintillator to its own emitted light is a key parameter to determine the overall sensitivity of a large-volume detector. The attenuation of light in an optical-pure LS is dominated by Rayleigh scattering, which poses an intrinsic limit to the transparency of LS. This work presents a spectrometric approach of measuring the wavelength-dependent scattering length of liquids by applying the Einstein-Smoluchowski theory to a measurement of scattered light intensity. The scattering lengths of linear alkyl benzene (LAB) and EJ309-base (Di-isopropylnaphthalene, DIN) were measured and are reported in the wavelength range of 410 to 520 nm. The spectral peak of scintillation light emitted by a nominal LS is around 430 nm at which the scattering length for LAB and EJ-309-base was determined to be 27.9 +/- 2.3 m and 6.1 +/- 0.6 m respectively.

physics.ins-det↗

Light Yield Quenching and Quenching Remediation in Liquid Scintillator Detectors

Quenching of light emission from an LAB based scintillator by the addition of organic amines and carboxylic acids is examined. Chemical functional groups of the quenching agents play an important role in this reduction. It is shown that "salt" formation at a 1:1 mole ratio in a mixed amine-acid system, reduces quenching by a factor of 2. Supporting NMR spectra are presented. This "quenching neutralization" has the potential to reduce the light loss incurred when metals complexed with quenching agents are loaded into organic scintillators.

physics.ins-det↗

Improved Short-Baseline Neutrino Oscillation Search and Energy Spectrum Measurement with the PROSPECT Experiment at HFIR

We present a detailed report on sterile neutrino oscillation and U-235 antineutrino energy spectrum measurement results from the PROSPECT experiment at the highly enriched High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. In 96 calendar days of data taken at an average baseline distance of 7.9 m from the center of the 85 MW HFIR core, the PROSPECT detector has observed more than 50,000 interactions of antineutrinos produced in beta decays of U-235 fission products. New limits on the oscillation of antineutrinos to light sterile neutrinos have been set by comparing the detected energy spectra of ten reactor-detector baselines between 6.7 and 9.2 meters. Measured differences in energy spectra between baselines show no statistically significant indication of antineutrinos to sterile neutrino oscillation and disfavor the Reactor Antineutrino Anomaly best-fit point at the 2.5$σ$ confidence level. The reported U-235 antineutrino energy spectrum measurement shows excellent agreement with energy spectrum models generated via conversion of the measured U-235 beta spectrum, with a $χ^2$/DOF of 31/31. PROSPECT is able to disfavor at 2.4$σ$ confidence level the hypothesis that U-235 antineutrinos are solely responsible for spectrum discrepancies between model and data obtained at commercial reactor cores. A data-model deviation in PROSPECT similar to that observed by commercial core experiments is preferred with respect to no observed deviation, at a 2.2$σ$ confidence level.

hep-ex↗

Note on arXiv:2005.05301, 'Preparation of the Neutrino-4 experiment on search for sterile neutrino and the obtained results of measurements'

We comment on the claimed observation [arXiv:arXiv:2005.05301] of sterile neutrino oscillations by the Neutrino-4 collaboration. Such a claim, which requires the existence of a new fundamental particle, demands a level of rigor commensurate with its impact. The burden lies with the Neutrino-4 collaboration to provide the information necessary to prove the validity of their claim to the community. In this note, we describe aspects of both the data and analysis method that might lead to an oscillation signature arising from a null experiment and describe additional information needed from the Neutrino-4 collaboration to support the oscillation claim. Additionally, as opposed to the assertion made by the Neutrino-4 collaboration, we also show that the method of 'coherent summation' using the $L/E$ parameter produces similar results to the methods used by the PROSPECT and the STEREO collaborations.

hep-ex↗

Nonfuel Antineutrino Contributions in the High Flux Isotope Reactor

Reactor neutrino experiments have seen major improvements in precision in recent years. With the experimental uncertainties becoming lower than those from theory, carefully considering all sources of $\overlineν_{e}$ is important when making theoretical predictions. One source of $\overlineν_{e}$ that is often neglected arises from the irradiation of the nonfuel materials in reactors. The $\overlineν_{e}$ rates and energies from these sources vary widely based on the reactor type, configuration, and sampling stage during the reactor cycle and have to be carefully considered for each experiment independently. In this article, we present a formalism for selecting the possible $\overlineν_{e}$ sources arising from the neutron captures on reactor and target materials. We apply this formalism to the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory, the $\overlineν_{e}$ source for the the Precision Reactor Oscillation and Spectrum Measurement (PROSPECT) experiment. Overall, we observe that the nonfuel $\overlineν_{e}$ contributions from HFIR to PROSPECT amount to 1\% above the inverse beta decay threshold with a maximum contribution of 9\% in the 1.8--2.0~MeV range. Nonfuel contributions can be particularly high for research reactors like HFIR because of the choice of structural and reflector material in addition to the intentional irradiation of target material for isotope production. We show that typical commercial pressurized water reactors fueled with low-enriched uranium will have significantly smaller nonfuel $\overlineν_{e}$ contribution.

nucl-ex↗

The PROSPECT Reactor Antineutrino Experiment

The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make both a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and to probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long baselines. PROSPECT utilizes a segmented $^6$Li-doped liquid scintillator detector for both efficient detection of reactor antineutrinos through the inverse beta decay reaction and excellent background discrimination. PROSPECT is a movable 4-ton antineutrino detector covering distances of 7m to 13m from the High Flux Isotope Reactor core. It will probe the best-fit point of the $\barν_e$ disappearance experiments at 4$σ$ in 1 year and the favored regions of the sterile neutrino parameter space at more than 3$σ$ in 3 years. PROSPECT will test the origin of spectral deviations observed in recent $θ_{13}$ experiments, search for sterile neutrinos, and address the hypothesis of sterile neutrinos as an explanation of the reactor anomaly. This paper describes the design, construction, and commissioning of PROSPECT and reports first data characterizing the performance of the PROSPECT antineutrino detector.

physics.ins-det↗

The Radioactive Source Calibration System of the PROSPECT Reactor Antineutrino Detector

The Precision Reactor Oscillation and Spectrum (PROSPECT) Experiment is a reactor neutrino experiment designed to search for sterile neutrinos with a mass on the order of 1 eV/c$^2$ and to measure the spectrum of electron antineutrinos from a highly-enriched $^{235}$U nuclear reactor. The PROSPECT detector consists of an 11 by 14 array of optical segments in $^{6}$Li-loaded liquid scintillator at the High Flux Isotope Reactor in Oak Ridge National Laboratory. Antineutrino events are identified via inverse beta decay and read out by photomultiplier tubes located at the ends of each segment. The detector response is characterized using a radioactive source calibration system. This paper describes the design, operation, and performance of the PROSPECT source calibration system.

physics.ins-det↗

Measurement of the Antineutrino Spectrum from $^{235}$U Fission at HFIR with PROSPECT

This Letter reports the first measurement of the $^{235}$U $\overline{ν_{e}}$ energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9m from the 85MW$_{\mathrm{th}}$ highly-enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678$\pm$304 (stat.) $\overline{ν_{e}}$-induced inverse beta decays (IBD), the largest sample from HEU fission to date, 99% of which are attributed to $^{235}$U. Despite broad agreement, comparison of the Huber $^{235}$U model to the measured spectrum produces a $χ^2/ndf = 51.4/31$, driven primarily by deviations in two localized energy regions. The measured $^{235}$U spectrum shape is consistent with a deviation relative to prediction equal in size to that observed at low-enriched uranium power reactors in the $\overline{ν_{e}}$ energy region of 5-7MeV.

nucl-ex↗

A Low Mass Optical Grid for the PROSPECT Reactor Antineutrino Detector

PROSPECT, the Precision Reactor Oscillation and SPECTrum experiment, is a short-baseline reactor antineutrino experiment designed to provide precision measurements of the $^{235}$U product $\overlineν_e$ spectrum of utilizing an optically segmented 4-ton liquid scintillator detector. PROSPECT's segmentation system, the optical grid, plays a central role in reconstructing the position and energy of $\overlineν_e$ interactions in the detector. This paper is the technical reference for this PROSPECT subsystem, describing its design, fabrication, quality assurance, transportation and assembly in detail. In addition, the dimensional, optical and mechanical characterizations of optical grid components and the assembled PROSPECT target are also presented. The technical information and characterizations detailed here will inform geometry-related inputs for PROSPECT physics analysis, and can guide a variety of future particle detection development efforts, such as those using optically reflecting materials or filament-based 3D printing.

physics.ins-det↗

Lithium-loaded Liquid Scintillator Production for the PROSPECT experiment

This work reports the production and characterization of lithium-loaded liquid scintillator (LiLS) for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). Fifty-nine 90 liter batches of LiLS (${}^6{\rm Li}$ mass fraction 0.082%$\pm$0.001%) were produced and samples from all batches were characterized by measuring their optical absorbance relative to air, light yield relative to a pure liquid scintillator reference, and pulse shape discrimination capability. Fifty-seven batches passed the quality assurance criteria and were used for the PROSPECT experiment.

physics.ins-det↗

Measurement of the $^8$B Solar Neutrino Flux in SNO+ with Very Low Backgrounds

A measurement of the $^8$B solar neutrino flux has been made using a 69.2 kt-day dataset acquired with the SNO+ detector during its water commissioning phase. At energies above 6 MeV the dataset is an extremely pure sample of solar neutrino elastic scattering events, owing primarily to the detector's deep location, allowing an accurate measurement with relatively little exposure. In that energy region the best fit background rate is $0.25^{+0.09}_{-0.07}$ events/kt-day, significantly lower than the measured solar neutrino event rate in that energy range, which is $1.03^{+0.13}_{-0.12}$ events/kt-day. Also using data below this threshold, down to 5 MeV, fits of the solar neutrino event direction yielded an observed flux of $2.53^{+0.31}_{-0.28}$(stat.)$^{+0.13}_{-0.10}$(syst.)$\times10^6$ cm$^{-2}$s$^{-1}$, assuming no neutrino oscillations. This rate is consistent with matter enhanced neutrino oscillations and measurements from other experiments.

hep-ex↗

First search for short-baseline neutrino oscillations at HFIR with PROSPECT

This Letter reports the first scientific results from the observation of antineutrinos emitted by fission products of $^{235}$U at the High Flux Isotope Reactor. PROSPECT, the Precision Reactor Oscillation and Spectrum Experiment, consists of a segmented 4 ton $^6$Li-doped liquid scintillator detector covering a baseline range of 7-9 m from the reactor and operating under less than 1 meter water equivalent overburden. Data collected during 33 live-days of reactor operation at a nominal power of 85 MW yields a detection of 25461 $\pm$ 283 (stat.) inverse beta decays. Observation of reactor antineutrinos can be achieved in PROSPECT at 5$σ$ statistical significance within two hours of on-surface reactor-on data-taking. A reactor-model independent analysis of the inverse beta decay prompt energy spectrum as a function of baseline constrains significant portions of the previously allowed sterile neutrino oscillation parameter space at 95% confidence level and disfavors the best fit of the Reactor Antineutrino Anomaly at 2.2$σ$ confidence level.

hep-ex↗

Performance of a segmented $^{6}$Li-loaded liquid scintillator detector for the PROSPECT experiment

This paper describes the design and performance of a 50 liter, two-segment $^{6}$Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source and optical calibration system, and materials that are compatible with the $^{6}$Li-doped scintillator developed by PROSPECT. We demonstrate a high light collection of 850$\pm$20 PE/MeV, an energy resolution of $σ$ = 4.0$\pm$0.2% at 1 MeV, and efficient pulse-shape discrimination of low $dE/dx$ (electronic recoil) and high $dE/dx$ (nuclear recoil) energy depositions. An effective scintillation attenuation length of 85$\pm$3 cm is measured in each segment. The 0.1% by mass concentration of $^{6}$Li in the scintillator results in a measured neutron capture time of $τ$ = 42.8$\pm$0.2 $μs$. The long-term stability of the scintillator is also discussed. The detector response meets the criteria necessary for achieving the PROSPECT physics goals and demonstrates features that may find application in fast neutron detection.

physics.ins-det↗

LUX-ZEPLIN (LZ) Technical Design Report

In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.

physics.ins-det↗

The PROSPECT Physics Program

The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long distances. PROSPECT is conceived as a 2-phase experiment utilizing segmented $^6$Li-doped liquid scintillator detectors for both efficient detection of reactor antineutrinos through the inverse beta decay reaction and excellent background discrimination. PROSPECT Phase I consists of a movable 3-ton antineutrino detector at distances of 7 - 12 m from the reactor core. It will probe the best-fit point of the $ν_e$ disappearance experiments at 4$σ$ in 1 year and the favored region of the sterile neutrino parameter space at $>$3$σ$ in 3 years. With a second antineutrino detector at 15 - 19 m from the reactor, Phase II of PROSPECT can probe the entire allowed parameter space below 10 eV$^{2}$ at 5$σ$ in 3 additional years. The measurement of the reactor antineutrino spectrum and the search for short-baseline oscillations with PROSPECT will test the origin of the spectral deviations observed in recent $θ_{13}$ experiments, search for sterile neutrinos, and conclusively address the hypothesis of sterile neutrinos as an explanation of the reactor anomaly.

physics.ins-det↗

Background Radiation Measurements at High Power Research Reactors

Research reactors host a wide range of activities that make use of the intense neutron fluxes generated at these facilities. Recent interest in performing measurements with relatively low event rates, e.g. reactor antineutrino detection, at these facilities necessitates a detailed understanding of background radiation fields. Both reactor-correlated and naturally occurring background sources are potentially important, even at levels well below those of importance for typical activities. Here we describe a comprehensive series of background assessments at three high-power research reactors, including $γ$-ray, neutron, and muon measurements. For each facility we describe the characteristics and identify the sources of the background fields encountered. The general understanding gained of background production mechanisms and their relationship to facility features will prove valuable for the planning of any sensitive measurement conducted therein.

physics.ins-det↗