SearcharxivSearch

arXiv subjects

R. Rossini

Publications and source records attributed to R. Rossini.

12 recordsLinked to original sources

Solar axion searches with RES-NOVA: projected sensitivity and first prototype limit

RES-NOVA is a cryogenic experiment based on PbWO4 scintillating bolometers produced from archaeological lead, originally designed to detect coherent elastic neutrino-nucleus scattering (CEvNS) from galactic core-collapse supernovae. We show that the same high-density, high-Z absorbers and sub-keV energy resolution make RES-NOVA an appealing probe of solar axions. We compute the expected signal from the Primakoff, ABC (atomic recombination and de-excitation, Bremsstrahlung, Compton), longitudinal-plasmon (LP), and 57Fe nuclear-line components of the solar axion flux, folded through the inverse-Primakoff and axioelectric detection channels in PbWO4, which probe the axion couplings to photons (g_a-gamma), electrons (g_ae), and nucleons (g_aN), respectively. We derive projected sensitivities for a 1 ton*y exposure of the RES-NOVA demonstrator in the (g_ae,g_a-gamma), (g_ae,g_aN), and (g_a-gamma,g_aN) planes. The projected reach in g_ae approaches that of XENONnT to within a factor of ~2, despite a background roughly four orders of magnitude higher, thanks to the large target mass, the high-Z enhancement of the axioelectric and inverse-Primakoff cross sections, and the sub-keV energy resolution. Because the inverse-Primakoff constraint on g_a-gamma relies on absorption rather than coherent conversion, it is independent of the axion mass, unlike bounds from magnetic helioscopes. We complement these projections with the first solar-axion exclusion limit obtained on real data with a 13 g PbWO4 prototype grown from archaeological lead, using a background-model-independent optimum-interval analysis. These results establish RES-NOVA as a promising multi-coupling probe of solar axions, with simultaneous sensitivity to g_ae, g_a-gamma and g_aN that is complementary to existing helioscope and direct-detection searches.

hep-ex

Probing large mass-splitting inelastic Dark Matter with RES-NOVA

Probing inelastic dark matter at large mass splittings requires heavy target nuclei, an extended recoil-energy range, and the high-velocity tail of the dark-matter distribution. We exploit these features with the RES-NOVA prototype detector, featuring a PbWO4 cryogenic calorimeter, produced from archaeological Pb and operated at the deep-underground laboratory of Gran Sasso of INFN (Italy), analyzing a 32.4 g day exposure over 2.5 keV - 1 MeV under both the Standard Halo Model (SHM) and a Large Magellanic Cloud (LMC)-motivated velocity distribution. We extend direct-detection constraints beyond the 330 keV reach of established technologies (e.g. Xe-based TPCs), probing splittings up to 510 (780) keV in the SHM (LMC) benchmark, while future exposures will probe new regions of the parameter space.

astro-ph.CO

Molecular effects in low-energy muon transfer from muonic hydrogen to oxygen

In the present study we determine from the available experimental data the cross section of muon transfer to molecular oxygen at low energies with account of the oxygen molecule structure. Building on an earlier work, the results highlight the role of the molecular structure effects and signifcantly improve the agreement with theoretical calculations of the muon transfer rate. An effcient computational model of the kinetics of processes involving muonic hydrogen atoms in gaseous mixture of H2 and O2 is developed and analyzed. The model is applied in the description of the FAMU experiment for the measurement of the hyperfine splitting in muonic hydrogen and the Zemach radius of the proton.

physics.atom-ph

Neutrino NSI in archaeological Pb

Dark matter direct detection experiments can observe solar neutrinos via coherent elastic neutrino-nucleus scattering, making it possible to test new physics in the neutrino sector. In this article, we study the sensitivity of RES-NOVA, a novel cryogenic calorimetric experiment employing PbWO$_4$ crystals grown from archaeological lead, to neutrino non-standard interactions (NSI). We perform a sensitivity study for a benchmark setup with a nominal energy threshold of 1 keV and an exposure of 1 ton$\cdot$y, both for a conservative (only heat readout) and ideal (heat and scintillation) background rejection scenario. We find that, in its nominal configuration, while not being sensitive to Standard Model solar $\nu$ interactions, RES-NOVA can reach sensitivities to NSI at the level of current global fits. With moderate or significant improvements of the threshold down to $0.5$ keV and $0.2$ keV, RES-NOVA will be able to achieve sensitivities beyond NSI global fit results, testing new areas of the parameter space in the electron and tau sectors, $\varepsilon_{ee}$, $\varepsilon_{\tau\tau}$, and $\varepsilon_{e\tau}$. A similar improvement in sensitivities is expected when instead increasing the exposure to 10 ton$\cdot$y.

hep-ph

Probing dark matter interactions with a RES-NOVA prototype cryogenic detector

We report on the operation of a 13 g PbWO$_4$ crystal, grown from archaeological Pb and operated as a cryogenic calorimeter in an underground environment. Read out with a Ge thermistor, the detector achieves a low energy threshold and, for the first time, enables the derivation of a dark matter exclusion limit using PbWO$_4$ as target material, for both spin-dependent interactions on neutrons and spin-independent interactions. Although limited in mass and not representative of the final RES-NOVA detector design, this prototype demonstrates effective control of mechanical vibrations and low-energy noise in a cryogenic system, which is a key requirement for rare-event searches. The experiment therefore provides a proof of principle for the RES-NOVA detection concept, validating the use of archaeological Pb-based PbWO$_4$ crystals, low-background operation, and robust data-analysis procedures. These results establish a solid technological and methodological foundation for future RES-NOVA detectors employing larger target masses and advanced thermal readout technologies.

physics.ins-det

First operation of the FAMU experiment at the RIKEN-RAL high intensity muon beam facility

The FAMU experiment, supported and funded by the Italian Institute of Nuclear Physics (INFN) and by the Science and Technology Facilities Council (STFC), aims to perform the first measurement of the ground-state hyperfine splitting (1S-hfs) of muonic hydrogen ($\mu H$). This quantity is highly sensitive to the proton's Zemach radius $R_Z$. An experimental determination of $R_Z$ provides significant constraints on the parametrization of the proton form factors as well as on theoretical models describing the proton's electromagnetic structure. Following years of technological and methodological development, the FAMU experiment began operations in 2023 at Port 1 of the RIKEN-RAL muon beam line at the ISIS Neutron and Muon Source facility (Didcot, UK). In this paper, we first describe the unique detection technique employed by FAMU to determine the 1S-hfs of muonic hydrogen, followed by a detailed presentation of the final experimental layout. Finally, we report the first outcome from the 2023 commissioning run and from the initial physics runs performed in 2023 and 2024.

physics.atom-ph

A new dark matter direct search based on archaeological Pb

The RES-NOVA project is an experimental initiative aimed at detecting neutrinos from the next galactic supernova using PbWO$_{4}$ cryogenic detectors, operated at low temperatures in a low-background environment. By utilizing archaeological lead (Pb) as the target material, RES-NOVA leverages its high radiopurity, large nuclear mass, and the natural abundance of $^{207}$Pb, making it well-suited for exploring both spin-independent and spin-dependent Dark Matter (DM) interactions via nuclear scattering. This work presents a background model developed for the RES-NOVA technology demonstrator and evaluates its implications for Dark Matter detection. Detailed calculations of nuclear matrix elements, combined with the unique properties of archaeological Pb, demonstrate RES-NOVA's potential as a complementary tool to existing direct detection experiments for studying Dark Matter interactions. The experiment will conduct DM searches over a broad mass range spanning 4 orders of magnitude, from sub-GeV/$c^2$ to TeV/$c^2$. In the most optimistic scenario, RES-NOVA is expected to probe DM-nucleon cross-sections down to 1$\times 10^{-43}$ cm$^2$ and 2$\times 10^{-46}$ cm$^2$ for candidates with masses of 2 GeV/$c^2$ and 20 GeV/$c^2$, respectively.

physics.ins-det

The muon beam monitor for the FAMU experiment: design, simulation, test and operation

FAMU is an INFN-led muonic atom physics experiment based at the RIKEN-RAL muon facility at the ISIS Neutron and Muon Source (United Kingdom). The aim of FAMU is to measure the hyperfine splitting in muonic hydrogen to determine the value of the proton Zemach radius with accuracy better than 1%.The experiment has a scintillating-fibre hodoscope for beam monitoring and data normalisation. In order to carry out muon flux estimation, low-rate measurements were performed to extract the single-muon average deposited charge. Then, detector simulation in Geant4 and FLUKA allowed a thorough understanding of the single-muon response function, crucial for determining the muon flux. This work presents the design features of the FAMU beam monitor, along with the simulation and absolute calibration measurements in order to enable flux determination and enable data normalisation.

physics.ins-det

Investigating the Proton Structure: The FAMU experiment

The article gives the motivations for the measurement of the hyperfine splitting (hfs) in the ground state of muonic hydrogen to explore the properties of the proton at low momentum transfer. It summarizes these proposed measurement methods and finally describes the FAMU experiment in more detail.

physics.atom-ph

One inch LaBr3:Ce detectors, with temperature control and improved time resolution for low energy X-rays spectroscopy

Large area LaBr3:Ce detectors with a SiPM array readout have been developed for the FAMU experiment at RAL. The aim was to have a good energy resolution for low energy X-rays detection (around 100 keV) and good timing properties of the signal pulse. Sixteen 1" detectors and twelve 1/2" detectors have been presently installed in the FAMU experiment and are taking data since March 2023, at RIKEN RAL Port 1.

physics.ins-det

Status of the detector setup for the FAMU experiment at RIKEN-RAL for a precision measurement of the Zemach radius of the proton in muonic hydrogen

The FAMU experiment at RIKEN-RAL is a muonic atom experiment with the aim to determine the Zemach radius of the proton by measuring the 1s hyperfine splitting in muonic hydrogen. The activity of the FAMU Collaboration in the years 2015-2023 enabled the final optimisation of the detector-target setup as well as the gas working condition in terms of temperature, pressure and gas mixture composition. The experiment has started its data taking in July 2023. The status of the detector setup for the 2023 experimental runs, for the beam characterisation and muonic X-ray detection in the 100-200 keV energy range, is presented and discussed.

physics.atom-ph

Large area LaBr3:Ce crystals read by SiPM arrays with improved timing and temperature gain drift control

Compact X-rays detectors made of 1/2" or 1" :LaBr3:Ce crystals of cubic shape with SiPM array readout have been developed for the FAMU experiment at RIKEN-RAL. The aim is a precise measurement of the proton Zemach radius with incoming muons. Additional applications may be found in medical physics, such as PET, homeland security and gamma-ray astronomy. Due to the high photon yield of LaBr3:Ce it was possible to use a simple readout scheme based on CAEN V1730 digitizers. Detectors, using Hamamatsu S13361 or S14161 arrays, have good FWHM energy resolutions up to 3 % (8 %) at the Cs137 Co57) peak, comparing well with the best results obtained with a photomultiplier's readout. Detailed studies were performed to correct online the drift with temperature of SiPM gain and to reduce the risetime/falltime of detectors' signals, that increased going from 1/2" to 1" detectors, due to the larger capacity of the used SiPM arrays.

physics.ins-det